Seyed Navid Naghib

Mr. Seyed Navid Naghib

University of Calabria
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Behrouz PirouzBehrouz Pirouz
Behrouz Pirouz
Domenico MazzeoDomenico Mazzeo
Domenico Mazzeo
Stefania Anna PalermoStefania Anna Palermo
Stefania Anna Palermo
Seyed Navid NaghibSeyed Navid Naghib
Seyed Navid Naghib
Michele TurcoMichele Turco
Michele Turco
Patrizia PiroPatrizia Piro
Patrizia Piro
The simulation of the ventilation and the heating, ventilation, and air conditioning (HVAC) systems of vehicles could be used in the energy demand management of vehicles besides improving the air quality inside their cabins. Moreover, traveling by public transport during a pandemic is a concerning factor, and analysis of the vehicle’s cabin environments could demonstrate how to decrease the risk and create a safer journey for passengers. Therefore, this article presents airflow analysis, air changes per hour (ACH), and respiration aerosols’ trajectory inside three vehicles, including a typical car, bus, and airplane. In this regard, three vehicles’ cabin environment boundary conditions and the HVAC systems of the selected vehicles were determined, and three-dimensional numerical simulations were performed using computational fluid dynamic (CFD) modeling. The analysis of the airflow patterns and aerosol trajectories in the selected vehicles demonstrate the critical impact of inflow, outflow, and passenger’s locations in the cabins. The CFD model results exhibited that the lowest risk could be in the airplane and the highest in the bus because of the location of airflows and outflows. The discrete CFD model analysis determined the ACH for a typical car of about 4.3, a typical bus of about 7.5, and in a typical airplane of about 8.5, which were all less than the standard protocol of infection prevention, 12 ACH. According to the results, opening windows in the cars could decrease the aerosol loads and improve the low ACH by the HVAC systems. However, for the buses, a new design for the outflow location or an increase in the number of outflows appeared necessary. In the case of airplanes, the airflow paths were suitable, and by increasing the airflow speed, the required ACH might be achieved. Finally, in the closed (recirculating) systems, the role of filters in decreasing the risk appeared critical.

15 July 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Behrouz PirouzBehrouz Pirouz
Behrouz Pirouz
Stefania Anna PalermoStefania Anna Palermo
Stefania Anna Palermo
Seyed Navid NaghibSeyed Navid Naghib
Seyed Navid Naghib
Domenico MazzeoDomenico Mazzeo
Domenico Mazzeo
Michele TurcoMichele Turco
Michele Turco
Patrizia PiroPatrizia Piro
Patrizia Piro
The purpose of heating, ventilation, and air conditioning (HVAC) systems are to create optimum thermal comfort and appropriate indoor air quality (IAQ) for occupants. Air ventilation systems can significantly affect the health risk in indoor environments, especially those by contaminated aerosols. Therefore, the main goal of the study is to analyze the indoor airflow patterns in the heating, ventilation, and air conditioning (HVAC) systems and the impact of outlets/windows. The other goal of this study is to simulate the trajectory of the aerosols from a human sneeze, investigate the impact of opening windows on the number of air changes per hour (ACH) and exhibit the role of dead zones with poor ventilation. The final goal is to show the application of computational fluid dynamics (CFD) simulation in improving the HVAC design, such as outlet locations or airflow rate, in addition to the placement of occupants. In this regard, an extensive literature review has been combined with the CFD method to analyze the indoor airflow patterns, ACH, and the role of windows. The airflow pattern analysis shows the critical impact of inflow/outflow and windows. The results show that the CFD model simulation could exhibit optimal placement and safer locations for the occupants to decrease the health risk. The results of the discrete phase simulation determined that the actual ACH could be different from the theoretical ACH as the short circuit and dead zones affect the ACH.

9 March 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
Behrouz PirouzBehrouz Pirouz
Behrouz Pirouz
Hana JavadiNejadHana JavadiNejad
Hana JavadiNejad
ACAnna Selene Chirillo
Anna Selene Chirillo
Seyed Navid NaghibSeyed Navid Naghib
Seyed Navid Naghib
Patrizia PiroPatrizia Piro
Patrizia Piro
The growing use of microfluidic-based devices necessitates an analysis of flow characteristics through both experimental methods and computational fluid dynamic (CFD) simulations. CFD simulations facilitate the investigation of various devices, including medical sensors, by providing detailed insights into flow behavior. In this study, we conducted experimental and CFD analysis of the microfluidic flow in three devices: a COVID-19 rapid test kit, a blood glucose kit, and a PDMS kit. Our findings revealed that the changes in wall adhesion (contact angles) during the capillary flow could cause significant deviation from theoretical flow speed predictions. A hemodynamic analysis of the blood glucose kit and PDMS kit showed that capillary filling decreased in length, and flow speed could depend on the microchannel diameter. CFD results indicated the prominent role of porosity in the simulation of porous media material such as the COVID-19 test kit, as well as surface tension coefficients and wall adhesion (contact angles) in blood glucose kits and PDMS kits. Therefore, considering adaptive dynamic contact angles in CFD simulation software such as Ansys-Fluent 2024 could result in a more accurate prediction than simplified theoretical techniques, which is useful for sensor optimization and development.

21 June 2025 in Energy Reports
Verified
Journal Article
Open access
Behrouz PirouzBehrouz Pirouz
Behrouz Pirouz
Seyed Navid NaghibSeyed Navid Naghib
Seyed Navid Naghib
Karolos J. KontoleonKarolos J. Kontoleon
Karolos J. Kontoleon
HNHana Javadi Nejad
Hana Javadi Nejad
PPPatrizia Piro
Patrizia Piro

25 March 2025 in Water
Verified
Journal Article
Open access
PDF file
Behrouz PirouzBehrouz Pirouz
Behrouz Pirouz
Seyed Navid NaghibSeyed Navid Naghib
Seyed Navid Naghib
Karolos J. KontoleonKarolos J. Kontoleon
Karolos J. Kontoleon
Bibin B SBibin B S
Bibin B S
Hana JavadiNejadHana JavadiNejad
Hana JavadiNejad
Patrizia PiroPatrizia Piro
Patrizia Piro
The advantages of green roofs and solar panels are numerous, but in dry periods, green roofs can place urban water resources under pressure, and the efficiency of solar panels can be affected negatively by high temperatures. In this context, our analysis investigated the advantages of bio-solar green roofs and evaluated the impact of green roofs on solar panel electricity production and solar panels on green roof water consumption. The assessment was conducted through simulation in a selected case study located in Cosenza, a city with a Mediterranean climate, with solar panels covering 10% to 60% of the green roof. Analyses were performed on the power outputs of four kinds of photovoltaic panels: polycrystalline, monocrystalline, bifacial, and Passivated Emitter and Rear Contact (PERC). The energy production and shade frequencies were simulated using PVGIS 5.3 and PVSOL 2024 R3. The impact of photovoltaic (PV) shade on the water consumption of green roofs was evaluated by image processing of a developed code in MATLAB R2024b. Moreover, water–energy interconnections in bio-solar green roof systems were assessed using the developed dynamic model in Vensim PLE 10.2.1. The results revealed that the water consumption by the green roof was reduced by 30.8% with a bio-solar coverage area of 60%. However, the electricity production by the PV panel was enhanced by about 4% with bio-solar green roofs and was at its maximum at a coverage rate of 50%. This investigation demonstrates the benefits of bio-solar green roofs, which can generate more electricity and require less irrigation.

2 April 2025 in Fluids
Verified
Journal Article
Open access
Behrouz PirouzBehrouz Pirouz
Behrouz Pirouz
Seyed Navid NaghibSeyed Navid Naghib
Seyed Navid Naghib
DCDiamante Chirillo
Diamante Chirillo
Hana JavadiNejadHana JavadiNejad
Hana JavadiNejad
Patrizia PiroPatrizia Piro
Patrizia Piro
In recent years, the application of microfluidic devices has increased, and three-dimensional (3D) printers for fabricating microdevices could be considered a suitable technique but, in some cases, may confront some issues. The main issues include channel roughness values, print orientation due to the 3D printer’s setup, filament materials, nozzle specifications, and condition. This study aims to analyze the capillary-driven flow in microdevices produced by 3D printers. Therefore, four 3D printer-based microchannels were investigated, and the capillary-driven flow of five liquids with different viscosities and contact angles was evaluated experimentally. The experimental results were compared with theoretical calculations using the Lucas−Washburn equation, and the impact of the width, length, and closed and open microchannel on flow behaviors was explored. The experimental results showed that the peak velocity for open and closed microchannels decreases with the length. Moreover, there were differences in flow behavior between open and closed microchannels. For the former, the maximum average velocity appeared in the microchannel with a width of 400 μm, while for the latter, it was for a width of 1000 μm. In addition, the flow velocity decreased when the viscosity increased, regardless of microchannel width. The decrease was more pronounced for the lower-viscosity liquids (ethanol and water) and smaller for the higher-viscosity ones (coffee and olive oil). Finally, the advantages and challenges of 3D printer-based microdevices are presented.