Szymon Niedźwiecki

Dr. Szymon Niedźwiecki

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2021 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
KDKamil Dulski
Kamil Dulski
NCNeha Chug
Neha Chug
CCCatalina Curceanu
Catalina Curceanu
ECEryk Czerwiński
Eryk Czerwiński
WWWojciech Wiślicki
Wojciech Wiślicki
Positronium created in a human body during PET scans hallmarks neoplastic tissues.

13 September 2024 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
JBJakub Baran
Jakub Baran
SBSteven Bass
Steven Bass
JCJarosław Choiński
Jarosław Choiński
NCNeha Chug
Neha Chug
Ewa Łucja StępieńEwa Łucja Stępień
Ewa Łucja Stępień
Positronium is abundantly produced within the molecular voids of a patient’s body during positron emission tomography (PET). Its properties dynamically respond to the submolecular architecture of the tissue and the partial pressure of oxygen. Current PET systems record only two annihilation photons and cannot provide information about the positronium lifetime. This study presents the in vivo images of positronium lifetime in a human, for a patient with a glioblastoma brain tumor, by using the dedicated Jagiellonian PET system enabling simultaneous detection of annihilation photons and prompt gamma emitted by a radionuclide. The prompt gamma provides information on the time of positronium formation. The photons from positronium annihilation are used to reconstruct the place and time of its decay. In the presented case study, the determined positron and positronium lifetimes in glioblastoma cells are shorter than those in salivary glands and those in healthy brain tissues, indicating that positronium imaging could be used to diagnose disease in vivo.

2 May 2025 in Science Advances
Verified
Journal Article
Open access
PMPawel Moskal
Pawel Moskal
DKDeepak Kumar
Deepak Kumar
SSSushil Sharma
Sushil Sharma
EBErmias Yitayew Beyene
Ermias Yitayew Beyene
NCNeha Chug
Neha Chug
KEKavya Valsan Eliyan
Kavya Valsan Eliyan
In state-of-the-art positron emission tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and parapositronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening avenues for exploring polarization correlations in PET as a diagnostic indicator.

2 January 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
PMPawel Moskal
Pawel Moskal
ECEryk Czerwiński
Eryk Czerwiński
JRJuhi Raj
Juhi Raj
SBSteven D. Bass
Steven D. Bass
EBErmias Y. Beyene
Ermias Y. Beyene
WWWojciech Wiślicki
Wojciech Wiślicki
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of 10−4 signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

4 April 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
CCCatalina Curceanu
Catalina Curceanu
CGCarlo Guaraldo
Carlo Guaraldo
DSDiana Laura Sirghi
Diana Laura Sirghi
AAAidin Amirkhani
Aidin Amirkhani
ABAta Baniahmad
Ata Baniahmad
JZJohann Zmeskal
Johann Zmeskal
Kaonic atoms measure the antikaon-nucleus interaction at almost zero relative energy, allowing one to determine basic low-energy quantum chromodynamics (QCD) quantities, namely, the antikaon-nucleon ( K ¯ N) scattering lengths. The latter are important for extracting the sigma terms which are built on the symmetry breaking part of the Hamiltonian, thereby providing a measure of chiral and SU(3) symmetries breaking. After discussing the sigma terms and their relations to the kaonic atoms, we describe the most precise measurement in the literature of kaonic hydrogen, performed at LNF-INFN by the SIDDHARTA experiment. Kaonic deuterium is still to be measured, and two experiments are planned. The first, SIDDHARTA-2 at LNF-INFN was installed on DA Φ NE in spring 2019 and will collect data in 2020. The second, E57 at J-PARC, will become operative in 2021.

31 December 2023 in Bio-Algorithms and Med-Systems
Verified
Journal Article
Closed access
FAFaranak Tayefi Ardebili
Faranak Tayefi Ardebili
SNSzymon Niedźwiecki
Szymon Niedźwiecki
PMPawel Moskal
Pawel Moskal
The Modular J-PET represents the latest advancement in the Jagiellonian-PET series, utilizing extended plastic scintillator strips. This prototype's modular design enables cost-effective imaging of multi-photon annihilation and positronium, allowing for easy assembly, portability, and versatility. Additionally, its lightweight construction facilitates static bed examinations with a mobile detection system that can be positioned conveniently alongside the patient, negating the requirement for spacious clinical settings. Comprising 24 modules arranged in regular 24-sided polygons circumscribing a 73.9 cm diameter circle, each module integrates 13 scintillator strips, measuring 50 cm in length and 6 mm × 24 mm in cross-section. Scintillation light is captured at both ends through analog Silicon Photomultipliers (SiPMs). This research presents Sensitivity of the Modular J-PET tomograph, adhering to the NEMA_NU 2-2018 standards. Sensitivity measurement was performed with 68Ge line source inside the 5 sleeves aluminium phantom placed at center of the detector`s field-of-view (FOV) and 10 cm offset from the center of detector. Analyzing the gathered data involved employing the specialized J-PET Framework software, developed within the C++ architecture. To validate the experimental findings, comparisons were made with GATE simulations, wherein the source and phantom were emulated in the same configuration as employed in the actual experiment. The system sensitivity of the Modular J-PET was assessed to be 1.03 0.02 cps/kBq in the center of the detector`s FOV with the peak sensitivity of 2.1 cps/kBq. However, the simulations indicate that at the center of the detector's FOV, the Modular J-PET achieves a system sensitivity of 1.32 0.03 cps/kBq, with a peak sensitivity of 2.9 cps/kBq.