Current state-of-the-art remote photoplethysmography (rPPG) algorithms are capable of extracting a clean pulse signal in ambient light conditions using a regular color camera, even when subjects move significantly. In this study, we investigate the feasibility of rPPG in the (near)-infrared spectrum, which broadens the scope of applications for rPPG. Two camera setups are investigated: one setup consisting of three monochrome cameras with different optical filters, and one setup consisting of a single RGB camera with a visible light blocking filter. Simulation results predict the monochrome setup to be more motion robust, but this simulation neglects parallax. To verify this, a challenging benchmark dataset consisting of 30 videos is created with various motion scenarios and skin tones. Experiments show that both camera setups are capable of accurate pulse extraction in all motion scenarios, with an average SNR of +6.45 and +7.26 dB, respectively. The single camera setup proves to be superior in scenarios involving scaling, likely due to parallax of the multicamera setup. To further improve motion robustness of the RGB camera, dedicated LED illumination with two distinct wavelengths is proposed and verified. This paper demonstrates that accurate rPPG measurements in infrared are feasible, even with severe subject motion.
Continuous monitoring of respiration is essential for early detection of critical illness. Current methods require sensors attached to the body and/or are not robust to subject motion. Alternative camera-based solutions have been presented using motion vectors and remote photoplethysmography. In this work, we present a non-contact camera-based method to detect respiration, which can operate in both visible and dark lighting conditions by detecting the respiratory-induced colour differences of the skin. We make use of the close similarity between skin colour variations caused by the beating of the heart and those caused by respiration, leading to a much improved signal quality compared to single-channel approaches. Essentially, we propose to find the linear combination of colour channels which suppresses the distortions best in a frequency band including pulse rate, and subsequently we use this same linear combination to extract the respiratory signal in a lower frequency band. Evaluation results obtained from recordings on healthy subjects which perform challenging scenarios, including motion, show that respiration can be accurately detected over the entire range of respiratory frequencies, with a correlation coefficient of 0.96 in visible light and 0.98 in infrared, compared to 0.86 with the best-performing non-contact benchmark algorithm. Furthermore, evaluation on a set of videos recorded in a Neonatal Intensive Care Unit (NICU) shows that this technique looks promising as a future alternative to current contact-sensors showing a correlation coefficient of 0.87.
Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO2) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted by motion-induced variations. We introduce a new principle that allows accurate remote measurements even during significant subject motion. We demonstrate the main advantage of the principle, i.e. that the optimal signature remains the same even when the SNR of the PPG signal drops significantly due to motion or limited measurement area. The evaluation uses recordings with breath-holding events, which induce hypoxemia in healthy moving subjects. The events lead to clinically relevant SpO2 levels in the range 80–100%. The new principle is shown to greatly outperform current remote ratio-of-ratios based methods. The mean-absolute SpO2-error (MAE) is about 2 percentage-points during head movements, where the benchmark method shows a MAE of 24 percentage-points. Consequently, we claim ours to be the first method to reliably measure SpO2 remotely during significant subject motion.
18 December 2020 in IEEE Journal of Biomedical and Health Informatics
Polysomnography (PSG) is the current gold standard for the diagnosis of sleep disorders. However, this multiparametric sleep monitoring tool also has some drawbacks, e.g. it limits the patient's mobility during the night and it requires the patient to come to a specialized sleep clinic or hospital to attach the sensors. Unobtrusive techniques for the detection of sleep disorders such as sleep apnea are therefore gaining increasing interest. Remote photoplethysmography using video is a technique which enables contactless detection of hemodynamic information. Promising results in near-infrared have been reported for the monitoring of sleep-relevant physiological parameters pulse rate, respiration and blood oxygen saturation. In this study we validate a contactless monitoring system on eight patients with a high likelihood of relevant obstructive sleep apnea, which are enrolled for a sleep study at a specialized sleep center. The dataset includes 46.5 hours of video recordings, full polysomnography and metadata. The camera can detect pulse and respiratory rate within 2 beats/breaths per minute accuracy 92% and 91% of the time, respectively. Estimated blood oxygen values are within 4 percentage-points of the finger-oximeter 89% of the time. These results demonstrate the potential of a camera as a convenient diagnostic tool for sleep apnea, and sleep disorders in general.
Polysomnography (PSG) remains the gold standard for sleep monitoring but is obtrusive in nature. Advances in camera sensor technology and data analysis techniques enable contactless monitoring of heart rate variability (HRV). In turn, this may allow remote assessment of sleep stages, as different HRV metrics indirectly reflect the expression of sleep stages. We evaluated a camera-based remote photoplethysmography (PPG) setup to perform automated classification of sleep stages in near darkness. Based on the contactless measurement of pulse rate variability, we use a previously developed HRV-based algorithm for 3 and 4-class sleep stage classification. Performance was evaluated on data of 46 healthy participants obtained from simultaneous overnight recording of PSG and camera-based remote PPG. To validate the results and for benchmarking purposes, the same algorithm was used to classify sleep stages based on the corresponding ECG data. Compared to manually scored PSG, the remote PPG-based algorithm achieved moderate agreement on both 3 class (Wake–N1/N2/N3–REM) and 4 class (Wake–N1/N2–N3–REM) classification, with average of 0.58 and 0.49 and accuracy of 81% and 68%, respectively. This is in range with other performance metrics reported on sensing technologies for wearable sleep staging, showing the potential of video-based non-contact sleep staging.
Camera-based pulse-oximetry has recently shown to be feasible, even when the signal is corrupted by noise and motion artifacts. Earlier work showed that using three instead of the common two wavelengths improves robustness of the measurement, however without a thorough investigation on the optimal wavelength selection. We therefore performed a search to identify these wavelengths to further improve the robustness of the measurement. Besides motion, it is empirically known that there are several other factors that influence the measurement leading to falsely-low or falsely-high SpO2 readings. These factors include the presence of dyshemoglobins or other species. In this paper, we use a theoretical skin-model to study how these factors influence the measurement, and how a proper wavelength selection can reduce the impact on the measurement. Additionally, we show that adding a third wavelength does not only improve robustness, but can also be exploited to create a reliability index for the measurement. Finally, we show that the presence of dyshemoglobins in arterial blood can not only be detected but also quantified. We illustrate this by comparing the estimated COHb levels of a small group of smokers and non-smokers, which typically have different CO-levels.