Lenard Conradi

Lenard Conradi

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2024 in Circulation
Verified
Journal Article
Closed access
JRJosep Rodés-Cabau
Josep Rodés-Cabau
HRHenrique Ribeiro
Henrique Ribeiro
SMSiamak Mohammadi
Siamak Mohammadi
VSVicenç Serra
Vicenç Serra
TATalal Al-Atassi
Talal Al-Atassi
OIon behalf of the VIVA (Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement for Treating Elderly Patients With Severe Aortic Stenosis and Small Aortic Annuli) Trial Investigators
on behalf of the VIVA (Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement for Treating Elderly Patients With Severe Aortic Stenosis and Small Aortic Annuli) Trial Investigators
BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%–3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4–22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P =0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P =1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P =0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1–4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P =0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P =0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P =0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03383445.

19 July 2023 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
MPMatteo Pagnesi
Matteo Pagnesi
WKWon-Keun Kim
Won-Keun Kim
SBSara Baggio
Sara Baggio
Andrea ScottiAndrea Scotti
Andrea Scotti
MBMarco Barbanti
Marco Barbanti
AMAntonio Mangieri
Antonio Mangieri

15 May 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
DDDanny Dvir
Danny Dvir
DTDidier Tchétché
Didier Tchétché
MLMartin B Leon
Martin B Leon
PGPhilippe Généreux
Philippe Généreux
BSBenjamin Seguy
Benjamin Seguy
SKSusheel Kodali
Susheel Kodali
This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%–100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%–100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%–99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%–99.0%)], without any cardiovascular deaths. Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI. This pivotal prospective, multicentre study presents favourable clinical outcomes of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients scheduled to undergo TAVI and at risk for coronary artery obstruction.

23 October 2023 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
Jorge NucheJorge Nuche
Jorge Nuche
AAAmr E. Abbas
Amr E. Abbas
VSVicenç Serra
Vicenç Serra
VVVictoria Vilalta
Victoria Vilalta
LNLuis Nombela
Luis Nombela
JRJosep Rodés-Cabau
Josep Rodés-Cabau

1 July 2023 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
JLJonas Lanz
Jonas Lanz
HMHelge Möllmann
Helge Möllmann
WKWon-Keun Kim
Won-Keun Kim
CBChristof Burgdorf
Christof Burgdorf
ALAxel Linke
Axel Linke
OIon behalf of the SCOPE I Investigators
on behalf of the SCOPE I Investigators
BACKGROUND: In the SCOPE I trial (Safety and Efficacy of the Symetis ACURATE Neo/TF Compared to the Edwards SAPIEN 3 Bioprosthesis), transcatheter aortic valve implantation with the self-expanding ACURATE neo (NEO) did not meet noninferiority compared with the balloon-expandable SAPIEN 3 (S3) device regarding a composite end point at 30 days due to higher rates of prosthetic valve regurgitation and acute kidney injury. Data on long-term durability of NEO are scarce. Here, we report whether early differences between NEO and S3 translate into differences in clinical outcomes or bioprosthetic valve failure 3 years after transcatheter aortic valve implantation. METHODS: Patients with severe aortic stenosis were randomized to transfemoral transcatheter aortic valve implantation with NEO or S3 at 20 European centers. Clinical outcomes at 3 years are compared using Cox proportional or Fine-Gray subdistribution hazard models by intention-to-treat. Bioprosthetic valve failure is reported for the valve-implant cohort. RESULTS: Among 739 patients, 84 of 372 patients (24.3%) had died in the NEO and 85 of 367 (25%) in the S3 group at 3 years. Comparing NEO with S3, the 3-year rates of all-cause death (hazard ratio, 0.98 [95% CI, 0.73–1.33]), stroke (subhazard ratio, 1.04 [95% CI, 0.56–1.92]), and hospitalization for congestive heart failure (subhazard ratio, 0.74 [95% CI, 0.51–1.07]) were similar between the groups. Aortic valve reinterventions were required in 4 NEO and 3 S3 patients (subhazard ratio, 1.32 [95% CI, 0.30–5.85]). New York Heart Association functional class ≤II was observed in 84% (NEO) and 85% (S3), respectively. Mean gradients remained lower after NEO at 3 years (8 versus 12 mm Hg; P <0.001). CONCLUSIONS: Early differences between NEO and S3 did not translate into significant differences in clinical outcomes or bioprosthetic valve failure throughout 3 years. REGISTRATION: URL: https://clinicaltrials.gov , Unique identifier: NCT03011346.

1 September 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
ODOspedale dell'Angelo
Ospedale dell'Angelo
GGGuglielmo Gallone
Guglielmo Gallone
WKWon-Keun Kim
Won-Keun Kim
JRJoerg Reifart
Joerg Reifart
VVVerena Veulemans
Verena Veulemans
FGFrancesco Giannini
Francesco Giannini
Background: An increased degree of aortic angulation (AA) represents a challenging feature for bioprosthesis positioning. Whether AA has an impact on procedural outcomes of contemporary self-expanding valves remains unsettled. The aim of this study was to evaluate the impact of AA on procedural outcomes of transcatheter aortic valve replacement with contemporary self-expanding valves. Methods: The HORSE (Horizontal Aorta in Transcatheter Self-Expanding Valves) is an international, retrospective registry including 3862 consecutive patients undergoing transcatheter aortic valve replacement with either Evolut R/PRO (n=1959) or ACURATE neo (n=1903) devices. Patients undergoing Evolut R 34 mm implantation were excluded as no comparable prosthesis size for ACURATE neo is available. AA was evaluated with preprocedural computed tomography, and its impact on device success was evaluated. Results: In the overall population, AA did not have any impact upon device success, also when adjusting for in-study outcome predictors (odds ratio for 1° increment, 0.99 [95% CI, 0.98–1.01], P =0.306). However, increased AA was associated with lower device success with use of the Evolut R/PRO valves (odds ratio, 0.97 [95% CI, 0.95–0.99]; P =0.004), but not the ACURATE neo valves (odds ratio, 1.00 [95% CI, 0.98–1.03], P =0.304). The best AA cutoff value predicting device success was 49° (47% of the study cohort). Among patients with AA≥49°, Evolut R/PRO valves were associated with lower device success as compared to the ACURATE neo valve (inverse probability weighting odds ratio, 0.62 [95% CI, 0.46–0.83]; P =0.002). Conclusions: Horizontal aorta, as defined by an AA ≥49°, is a common feature among transcatheter aortic valve replacement candidates and predicts device failure of the Evolut R/PRO valves, but not of the ACURATE neo valve. AA may be an effect modifier of the association between self-expanding valve type and device success.