Andrzej Polanczyk

Prof. Andrzej Polanczyk

The Main School of Fire Service
+1
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
MPMarek Podyma
Marek Podyma
LSLudomir Stefanczyk
Ludomir Stefanczyk
WSWojciech Szubert
Wojciech Szubert
Ireneusz ZbicinskiIreneusz Zbicinski
Ireneusz Zbicinski

1 June 2018 in Medicina
Verified
Journal Article
Open access
PDF file
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
MPMichał Podgórski
Michał Podgórski
TWTomasz Wozniak
Tomasz Wozniak
LSLudomir Stefanczyk
Ludomir Stefanczyk
Michał StrzeleckiMichał Strzelecki
Michał Strzelecki
Background and objectives: Brain ischemic stroke is caused by impaired or absolutely blocked blood flow into the brain regions. Despite the large number of possible origins, there is no general strategy for preventive treatment. In this paper, we aimed to predict the hemodynamics in a patient who experienced a critical stenosis operation in the carotid artery. This is a unique study where we used medical data together with the computational fluid (CFD) technique not to plan the surgery, but to predict its outcome. Materials and Methods: AngioCT data and blood perfusion of brain tissue (CT-perfusion) together with CFD technique were applied for stroke formation reconstruction in different clinical conditions. With the use of self-made semiautomatic algorithm for image processing and 3DDoctror software, 3D-vascular geometries before and after surgical intervention were reconstructed. As the paper is focused on the analysis of stroke appearance, apparent stroke was simulated as higher and lower pressure values in the cranial part due to different outcomes of the surgical intervention. This allowed to investigate the influence of spatial configuration and pressure values on blood perfusion in the analyzed circulatory system. Results: Application of CFD simulations for blood flow reconstruction for clinical conditions in the circulatory system accomplished on average 98.5% and 98.7% accuracy for CFD results compared to US-Doppler before and after surgical intervention, respectively. Meanwhile, CFD results compared to CT-perfusion indicated an average 89.7% and 92.8% accuracy before and after surgical intervention, respectively. Thus, the CFD is a reliable approach for predicting the patient hemodynamics, as it was confirmed by postoperative data. Conclusions: Our study indicated that the application of CFD simulations for blood flow reconstruction for clinical conditions in circulatory system reached 98% and 90% accuracy for US-Doppler and CT-perfusion, respectively. Therefore, the proposed method might be used as a tool for reconstruction of specific patients’ hemodynamics after operation of critical stenosis in the carotid artery. However, further studies are necessary to confirm its usefulness in clinical practice.

1 January 2010 in Pharmacological Reports
Verified
Journal Article
Closed access
Aleksandra Piechota-PolanczykAleksandra Piechota-Polanczyk
Aleksandra Piechota-Polanczyk
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
AGAnna Gorąca
Anna Gorąca

18 December 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
TWTomasz Węsierski
Tomasz Węsierski
ADAnna Dmochowska
Anna Dmochowska
ZSZdzisław Salamonowicz
Zdzisław Salamonowicz
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
This article examines electrochemical carbon monoxide (CO) sensors used as mobile devices by rescue and firefighting units in Poland. The conducted research indicates that the presence of chlorine (Cl2), ammonia (NH3), hydrogen sulfide (H2S), hydrogen chloride (HCl), hydrogen cyanide (HCN), nitrogen (IV) oxide (NO2), and sulfur (IV) oxide (SO2) in the atmosphere does not affect the functioning of the electrochemical CO sensor. In the case of this sensor, there was a significant cross effect in relation to hydrogen (H2). It was found that the time and manner of using the sensor affects the behavior in relation to H2. Such a relationship was not recorded for CO. Measurements in a mixture of CO and H2 confirm the effect of hydrogen on the changes taking place inside the sensor. Independently of the ratio of H2 to CO, readings of CO were flawed. All analyses showed a significant difference between the electrochemical CO sensor readings and the expected values. Only in experiments with a 1:3 mixture of CO and H2 was the relative error less than 15%. The relative error in the analyzed concentration range for a sensor with an additional compensation electrode ranged from 7% to 38%; for a sensor without this electrode, it ranged from 23% to 55%. It was ascertained that in the cases of measurements for tests carried out at higher concentrations of H2 in relation to CO, a sensor with an additional electrode is significantly better (more accurate) than a sensor without such an electrode. Differences at the significance level p = 0.01 for measurements made in the CO:H2 mixture at a ratio of 1:3 were ascertained.

11 October 2021 in Diagnostics
Verified
Journal Article
Open access
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
Aleksandra Piechota-PolanczykAleksandra Piechota-Polanczyk
Aleksandra Piechota-Polanczyk
IHIhor Huk
Ihor Huk
CNChristoph Neumayer
Christoph Neumayer
JBJulia Balcer
Julia Balcer
Michał StrzeleckiMichał Strzelecki
Michał Strzelecki
Using computer tomography angiography (CTA) and computational structural analysis, we present a non-invasive method of mass flow rate/velocity and wall stress analysis in type B aortic dissection. Three-dimensional (3D) computer models of the aorta were calculated using pre-operative (baseline) and post-operative CT data from 12 male patients (aged from 51 to 64 years) who were treated for acute type B dissection. A computational fluid dynamics (CFD) technique was used to quantify the displacement forces acting on the aortic wall in the areas of endografts placement. The mass flow rate and wall stress were measured and quantified using the CFD technique. The CFD model indicated the places with a lower value of blood velocity and shear rate, which corelated with higher blood viscosity and a probability of thrombus appearance. Moreover, with the increase in Hct, blood viscosity also increased, while the intensity of blood flow provoked changing viscosity values in these areas. Furthermore, the velocity gradient near the tear surface caused high wall WSS; this could lead to a decreased resistance in the aorta’s wall with further implications to a patient.

29 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
MMMałgorzata Majder-Łopatka
Małgorzata Majder-Łopatka
TWTomasz Węsierski
Tomasz Węsierski
AAArtur Ankowski
Artur Ankowski
KRKamil Ratajczak
Kamil Ratajczak
DDDominik Duralski
Dominik Duralski
Andrzej PolanczykAndrzej Polanczyk
Andrzej Polanczyk
Fires in landfills, where used plastic packaging waste is discarded, have shown how great a fire hazard these types of materials pose. In this study, the course of thermo-oxidation of samples made of polypropylene (PP), polystyrene (PS), and polyethylene terephthalate (PET) based plastics was determined. Based on an analysis of the dissociation energy of bonds between atoms in a polymer molecule, the mechanisms responsible for the character and course of degradation were observed. It was found that the degradation rate of PP and PS could be a result of the stability of C-H bonds on the tertiary carbon atom. In the case of PS, due to facilitated intramolecular hydrogen transfer, stabilization of hydroperoxide, and formation of a stable tertiary alcohol molecule, the onset of degradation is shifted towards higher temperatures than in the case of PP. Notably, the PP fragmentation occurs to a greater extent due to the easier course of β-scission. In addition, it was found that during a fire, the least amount of heat would be generated by thermo-oxidation of PS-based plastics. This is a result of the formation of a styrene molecule during decomposition that, due to the high stability of bonds in the aromatic ring, escapes from the combustion zone without oxidation. It has been proven that the greatest thermal effect accompanies PET decomposition, during which a phenyl radical is produced, where the C-H bonds break more easily in comparison with the bonds of an intact ring.