Johanna Schachl

Johanna Schachl

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2023 in ASAIO Journal
Verified
Journal Article
Closed access
JSJohanna Schachl
Johanna Schachl
MSMartin Stoiber
Martin Stoiber
MSMartina Socha
Martina Socha
Daniel ZimpferDaniel Zimpfer
Daniel Zimpfer
Dominik WiedemannDominik Wiedemann
Dominik Wiedemann
Thomas SchlöglhoferThomas Schlöglhofer
Thomas Schlöglhofer
Driveline infection (DLI) is associated with increased mortality and morbidity in left ventricular assist device (LVAD) patients. Because trauma to the driveline exit-site (DLES) is a risk factor for DLI, adhesive anchoring devices are used to immobilize the DL. In this study, commonly used products (identified through literature review and contact with nine international VAD implantation centers) were mechanically characterized to evaluate their effectiveness in preventing DLES trauma. Eight devices were tested in an in vitro abdominal model of the DLES, where a tensile force (10 N) was applied to a HeartMate 3 DL, whereas the resulting force (F Total) on the DLES was recorded using a three-axis load cell. Four devices (CathGrip: F Total = 2.1 ± 0.4 N, Secutape: F Total = 2.6 ± 0.3 N, Hollister: F Total = 2.7 ± 0.5 N, Tubimed: F Total = 2.9 ± 0.2 N) were significantly (p < 0.05) better at preventing tensile forces at the DLES compared to the other four devices (Main-Lock: F Total = 3.7 [0.7] N, Secutape sensitive: F Total = 3.9 ± 0.4 N, Foley Anchor: F Total = 4.3 ± 0.5 N, Grip-Lok: F Total = 5.4 ± 0.8 N). Immobilization of the DL with each anchoring device resulted in lower tensile force on the DLES than without an anchor (F Total = 8.2 ± 0.3 N). In conclusion, the appropriate selection of anchoring devices plays a critical role in reducing the risk of DLI, whereas the CathGrip, Secutape, Hollister, or Tubimed were superior in preventing trauma to the DLES in this study.

20 September 2024 in Artificial Organs
Verified
Journal Article
Open access
JSJohanna Schachl
Johanna Schachl
MKMarkus Königshofer
Markus Königshofer
MSMartin Stoiber
Martin Stoiber
MSMartina Socha
Martina Socha
CGChristian Grasl
Christian Grasl
Thomas SchlöglhoferThomas Schlöglhofer
Thomas Schlöglhofer
Background: Cold atmospheric plasma (CAP) therapy has been recognized as effective treatment option for reducing bacterial load in chronic wounds, such as adult ventricular assist device (VAD) driveline exit‐site infections. Currently, there have been no reports on the safety and efficacy of CAP therapy for pediatric cannula infections and inflammations in paracorporeal pulsatile VADs.Methods: The mechanical strength of Berlin Heart EXCOR cannulas were tested both before and after CAP treatment (SteriPlas, Adtec Healthcare Limited, UK) to prove material safety. A ring tensile test of 20 untreated and 20 CAP‐treated (5 min) EXCOR cannulas (Ø12mm), assessed the force at the breaking point of the cannulas (Fmax), at 25% (F25%) and 50% (F50%) of the maximum displacement. Additionally, the scanning electron microscope (SEM) micrographs for both groups examined any surface changes. Finally, the case of a 13‐year‐old male EXCOR patient with cannula infections, treated with CAP over 100 days, is presented.Results: The in vitro measurements revealed no statistically significant differences in mechanical strength between the control and CAP group for F25% (8.18 ± 0.36 N, vs. 8.02 ± 0.43 N, p = 0.21), F50% (16.87 ± 1.07 N vs. 16.38 ± 1.32 N, p = 0.21), and FMAX (44.55 ± 3.24 N vs. 42.83 ± 4.32 N, p = 0.16). No surface structure alterations were identified in the SEM micrographs. The patient's cannula exit‐sites showed a visible improvement in DESTINE wound staging, reduction in bacterial load and inflammatory parameters after CAP treatment without any side effects.Conclusion: Overall, CAP therapy proved to be a safe and effective for treating EXCOR cannula exit‐site wound healing disorders in one pediatric patient, but further studies should investigate this therapy in more detail.

Verified
Journal Article
Open access
PDF file
RMRoxana Moayedifar
Roxana Moayedifar
JSJohanna Schachl
Johanna Schachl
MKMarkus Königshofer
Markus Königshofer
MSMartin Stoiber
Martin Stoiber
JRJulia Riebandt
Julia Riebandt
Thomas SchlöglhoferThomas Schlöglhofer
Thomas Schlöglhofer
Background/Objectives: Secure large-bore cannula insertion is critical for effective extracorporeal membrane oxygenation (ECMO), as inadequate fixation can lead to complications such as infection, dislodgment, and life-threatening events. With inconsistent guidelines for ECMO line management, this study compares the effectiveness of traditional suture fixation to an adhesive securement method in the prevention of ECMO cannula dislodgment using an in vitro model. Methods: Porcine skin and muscle tissue sections were prepared and mounted in a custom holder. A 21F venous ECMO cannula was inserted using a modified Seldinger technique. Three fixation methods were randomly compared: (1) three silk sutures, and (2a) one silk suture with a CathGrip adhesive anchoring device. In addition, a sub-analysis was performed using (2b) the Hollister adhesive anchoring device. A uniaxial testing machine simulated 50 mm cannula dislodgment, measuring tensile forces at 12.5, 25, and 50 mm dislodgment points. Results: A total of 26 ECMO cannula fixations using sutures, 26 with adhesive CathGrip, six with a Hollister device, and three controls were tested across six porcine samples. Sutures demonstrated greater variability in force at maximum dislocation, with 27% rupturing at 50 mm. In contrast, CathGrip provided greater flexibility without tearing. The adhesive exhibited higher stiffness (2.38 N/mm vs. 2.09 N/mm, p < 0.001) and dislodgment energy (0.034 J vs. 0.032 J, p = 0.002) in the 0–5 mm range, while sutures showed greater stiffness in the 5–50 mm range (1.42 N/mm vs. 1.18 N/mm, p < 0.001). At larger displacements (25 mm and 50 mm) and in total energy absorption, no statistically significant differences were observed (p = 0.57). In a sub-analysis, the six fixations using the Hollister device exhibited higher variability and significantly lower dislodgment forces at 25 mm (p = 0.033) and 50 mm (p = 0.004) compared to the CathGrip device. Conclusions: This study suggests that adhesive anchoring methods, such as CathGrip, may provide comparable or potentially superior fixation strength to sutures for ECMO cannula stabilization under controlled conditions. However, further research, including clinical trials, is necessary to confirm these findings, evaluate long-term performance, and explore the implications for dislodgment risk and infection prevention in clinical practice.