Markus Königshofer

Mr. Markus Königshofer

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2021 in Frontiers in Physics
Verified
Journal Article
Open access
MKMarkus Königshofer
Markus Königshofer
MSMartin Stoiber
Martin Stoiber
EUEwald Unger
Ewald Unger
CGChristian Grasl
Christian Grasl
FMFrancesco Moscato
Francesco Moscato
Additive manufacturing machines, based on the multimaterial jetting technology, are widely used for three-dimensional (3D) printing of sophisticated medical models, which are aimed to be used for preoperative planning and surgical training. Gaining knowledge of process-related influences on mechanical and dimensional properties of 3D-printed parts makes up an essential basis for the design and manufacture of medical models. There are few studies on characterization of multimaterial parts, and those are limited to tests that are not based on standardized methods. Within the scope of this work, mechanical and dimensional investigations were performed on multimaterial parts that were printed using an Objet500–Connex3 3D printer (Stratasys Ltd., Minnesota, Eden Prairie, MN, USA). Among test methods listed in DIN EN ISO 17296-3, tensile tests were chosen for mechanical characterization. In the tensile tests, combinations of four different materials (Tango+, VeroClear, VeroPureWhite, MED610) were tested in three build orientations (XY, YX, ZX). To investigate the orientation-dependent printing accuracy, the tensile specimens were further checked for their dimensional accuracy. Statistically significant variations in the mechanical properties were found between different orientation levels. In general, specimens printed in XY orientation show higher tensile strength than YX- and ZX-oriented specimens. The tensile moduli determined are in the range from 0.2 to 2,500 MPa and compare well with the tensile moduli found in soft biological tissues. Dimensional deviations were found highest for the length of ZX-oriented tensile specimens. For this orientation level, it could be observed that multimaterial specimens, which contain higher percentage of the soft material Tango+, are characterized by higher shrinkage. For tensile specimens printed from the pure photopolymer Tango+, a shrinkage of 4.6% in length was determined. In summary, it was found that with multimaterial jetting technology, the increased shrinkage and lower mechanical strength in the ZX direction must be considered in the design process.

14 March 2024 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
MBMartin Bittner-Frank
Martin Bittner-Frank
ASAndreas Strassl
Andreas Strassl
EUEwald Unger
Ewald Unger
Lena HirtlerLena Hirtler
Lena Hirtler
BEBarbara Eckhart
Barbara Eckhart
EBEmir Benca
Emir Benca
The introduction of three-dimensional (3D) printed anatomical models has garnered interest in pre-operative planning, especially in orthopedic and trauma surgery. Identifying potential error sources and quantifying their effect on the model dimensional accuracy are crucial for the applicability and reliability of such models. In this study, twenty radii were extracted from anatomic forearm specimens and subjected to osteotomy to simulate a defined fracture of the distal radius (Colles’ fracture). Various factors, including two different computed tomography (CT) technologies (energy-integrating detector (EID) and photon-counting detector (PCD)), four different CT scanners, two scan protocols (i.e., routine and high dosage), two different scan orientations, as well as two segmentation algorithms were considered to determine their effect on 3D model accuracy. Ground truth was established using 3D reconstructions of surface scans of the physical specimens. Results indicated that all investigated variables significantly impacted the 3D model accuracy (p < 0.001). However, the mean absolute deviation fell within the range of 0.03 ± 0.20 to 0.32 ± 0.23 mm, well below the 0.5 mm threshold necessary for pre-operative planning. Intra- and inter-operator variability demonstrated fair to excellent agreement for 3D model accuracy, with an intra-class correlation (ICC) of 0.43 to 0.92. This systematic investigation displayed dimensional deviations in the magnitude of sub-voxel imaging resolution for all variables. Major pitfalls included missed or overestimated bone regions during the segmentation process, necessitating additional manual editing of 3D models. In conclusion, this study demonstrates that 3D bone fracture models can be obtained with clinical routine scanners and scan protocols, utilizing a simple global segmentation threshold, thereby providing an accurate and reliable tool for pre-operative planning.

9 July 2024 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
MBMartin Bittner-Frank
Martin Bittner-Frank
ASAndreas Strassl
Andreas Strassl
EUEwald Unger
Ewald Unger
Lena HirtlerLena Hirtler
Lena Hirtler
BEBarbara Eckhart
Barbara Eckhart
EBEmir Benca
Emir Benca
Knowledge of the minimal detectable bone fracture gap is essential in three-dimensional (3D) models, particularly in pre-operative planning of osteosynthesis to avoid overlooking gaps. In this study, defined incisions and bony displacements ranging from 100 to 400 µm were created in diaphyseal radii in 20 paired forearm specimens and verified with light microscopy. The specimens were scanned utilizing different computed tomography (CT) technologies/scanners, specimen positionings, scan protocols, image segmentations, and processing protocols. Inter- and intra-operator variabilities were reported as coefficient kappa. In CT images, fracture gaps of 100 µm and bone lamellae of 300 µm and 400 µm width were identified at a rate of 80 to 100%, respectively, independent of the investigated settings. In contrast, only 400µm incisions and bony displacements were visible in digital 3D models, with detection rates dependent on CT technology, image segmentation, and post-processing algorithm. 3D bone models based on state-of-the-art CT imaging can reliably visualize clinically relevant bone fracture gap sizes. However, verification of fractures to be surgically addressed should be verified with the original CT image series. Graphical Abstract

1 April 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
GOGunpreet Coudert Oberoi
Gunpreet Coudert Oberoi
EKErik Kornfellner
Erik Kornfellner
MKMarkus Königshofer
Markus Königshofer
BRBernhard Rosenauer
Bernhard Rosenauer
MOMarkus Ortner
Markus Ortner
EUEwald Unger
Ewald Unger
Realistic soft-tissue behaviour is essential for surgical training, yet most additively manufactured models remain mechanically homogeneous. The purpose of

8 June 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LKLorenz Kiss
Lorenz Kiss
JGJean-Lynce Gnanago
Jean-Lynce Gnanago
SWStefan Wampl
Stefan Wampl
MWMarcos Wolf
Marcos Wolf
CBChristopher Breitenfelder
Christopher Breitenfelder
ASAlbrecht Ingo Schmid
Albrecht Ingo Schmid
Magnetic Resonance Elastography (MRE) can be used to estimate biomechanical parameters, e.g., shear stiffness of human tissue. As such, it is an imaging-based extension of palpation. To perform MRE, mechanical waves are induced into the tissue by transducers or actuators. The resulting periodic microscopic tissue displacements are recorded using phase-contrast magnetic resonance imaging (MRI). Good transducers need sufficient vibration amplitudes and frequency stability with little contributions of higher order harmonics. For clinical use, it needs to be compact for comfort as well as interference with RF coil placement. Safe operation in strong electromagnetic fields is a must. Setup procedures should be simple and quick. Here, a new compact pneumatically driven gravitational transducer (CPT) for MR elastography is presented. It consists of rotating unbalances stacked on either side of a turbine. Additional insertable masses allow adjustment of the vibration amplitude at a set frequency. Additive manufacturing and milling were combined to produce the transducer. The flat design of the CPT allows for placement between body and receiver coil with minimal sensitivity loss in most relevant targets. PID control is used to precisely control vibration frequency, based on optical detection of rotation cycles. It adjusts a valve in the air supply of the turbine. It is constructed using non-magnetic, non-conducting materials, which makes it inherently MRI-safe. The electronics, fittings and valves are placed in a control unit (CU) outside the magnet room. A hose and two optical fibres connect the transducer and the CU. The performance of the transducer was thoroughly bench tested and phantom experiments in the MRI scanner demonstrated the feasibility and robustness of the system. The frequency control was excellent for a pneumatic system (FWHM 0.04-0.20 Hz) across a wide range (50-130 Hz), while amplitudes of higher harmonics are very low (1.9-8.1 % 1st, 0.2-4.6 % 2nd order). Imaging data confirm that the CPT generated displacements which could be recorded with MR elastography pulse sequences. In conclusion, we present a new MRE pneumatically driven gravitational transducer, Its advantages are the combination of the following features: It requires no electrical components in the vicinity of the MR scanner. It performs equally well as electromechanically driven systems while it outperforms pneumatic designs in terms of frequency stability. Its compact design allows for flexibility in placement with a variety of RF coils and target tissues in the body. It consists of low-cost components and is easily used. We conclude that the combination of the CPT’s features constitute a substantial improvement in MRE transducer design.

Verified
Journal Article
Open access
PDF file
RMRoxana Moayedifar
Roxana Moayedifar
JSJohanna Schachl
Johanna Schachl
MKMarkus Königshofer
Markus Königshofer
MSMartin Stoiber
Martin Stoiber
JRJulia Riebandt
Julia Riebandt
Thomas SchlöglhoferThomas Schlöglhofer
Thomas Schlöglhofer
Background/Objectives: Secure large-bore cannula insertion is critical for effective extracorporeal membrane oxygenation (ECMO), as inadequate fixation can lead to complications such as infection, dislodgment, and life-threatening events. With inconsistent guidelines for ECMO line management, this study compares the effectiveness of traditional suture fixation to an adhesive securement method in the prevention of ECMO cannula dislodgment using an in vitro model. Methods: Porcine skin and muscle tissue sections were prepared and mounted in a custom holder. A 21F venous ECMO cannula was inserted using a modified Seldinger technique. Three fixation methods were randomly compared: (1) three silk sutures, and (2a) one silk suture with a CathGrip adhesive anchoring device. In addition, a sub-analysis was performed using (2b) the Hollister adhesive anchoring device. A uniaxial testing machine simulated 50 mm cannula dislodgment, measuring tensile forces at 12.5, 25, and 50 mm dislodgment points. Results: A total of 26 ECMO cannula fixations using sutures, 26 with adhesive CathGrip, six with a Hollister device, and three controls were tested across six porcine samples. Sutures demonstrated greater variability in force at maximum dislocation, with 27% rupturing at 50 mm. In contrast, CathGrip provided greater flexibility without tearing. The adhesive exhibited higher stiffness (2.38 N/mm vs. 2.09 N/mm, p < 0.001) and dislodgment energy (0.034 J vs. 0.032 J, p = 0.002) in the 0–5 mm range, while sutures showed greater stiffness in the 5–50 mm range (1.42 N/mm vs. 1.18 N/mm, p < 0.001). At larger displacements (25 mm and 50 mm) and in total energy absorption, no statistically significant differences were observed (p = 0.57). In a sub-analysis, the six fixations using the Hollister device exhibited higher variability and significantly lower dislodgment forces at 25 mm (p = 0.033) and 50 mm (p = 0.004) compared to the CathGrip device. Conclusions: This study suggests that adhesive anchoring methods, such as CathGrip, may provide comparable or potentially superior fixation strength to sutures for ECMO cannula stabilization under controlled conditions. However, further research, including clinical trials, is necessary to confirm these findings, evaluate long-term performance, and explore the implications for dislodgment risk and infection prevention in clinical practice.