Jean-Lynce Gnanago

Jean-Lynce Gnanago

Auto-generated profile, based on publicly available information

Jean-Lynce Gnanago

Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JGJean-Lynce Gnanago
Jean-Lynce Gnanago
ETErnesto Gomez Tamm
Ernesto Gomez Tamm
AHAndreas Hodul
Andreas Hodul
QNQuang Nguyen
Quang Nguyen
MOMarkus Ortner
Markus Ortner
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
The design, fabrication, assembly and testing of a modular dynamic torso phantom for magnetic resonance imaging (MRI) is presented. The phantom is composed of fully MRI-compatible materials and consists of a saline-filled acrylic shell, with dimensions comparable to a human torso, and three distinct interior motion modules. Two linear piezo stages are used to mimic respiratory motion of the chest-wall (≤ 10 mm; cycle time ≥ 2 s) and the abdominal organs (≤ 45 mm; cycle time ≥ 2 s). A pneumatic system is used to move a heart mock-up to represent cardiac motion (≤ 19 mm, rate ≤ 3 Hz). The motion capabilities and MRI compatibility of the phantom are tested in 3 T MRI experiments. The closed-loop control of the phantom’s breathing modules allows for accurate positioning and timing with absolute differences between input and output values ≤ 0.61 mm and ≤ 0.06 s. The purpose of this phantom is to serve as a scientific instrument for the future development and evaluation of motion tracking and artifact compensation techniques.

8 June 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LKLorenz Kiss
Lorenz Kiss
JGJean-Lynce Gnanago
Jean-Lynce Gnanago
SWStefan Wampl
Stefan Wampl
MWMarcos Wolf
Marcos Wolf
CBChristopher Breitenfelder
Christopher Breitenfelder
ASAlbrecht Ingo Schmid
Albrecht Ingo Schmid
Magnetic Resonance Elastography (MRE) can be used to estimate biomechanical parameters, e.g., shear stiffness of human tissue. As such, it is an imaging-based extension of palpation. To perform MRE, mechanical waves are induced into the tissue by transducers or actuators. The resulting periodic microscopic tissue displacements are recorded using phase-contrast magnetic resonance imaging (MRI). Good transducers need sufficient vibration amplitudes and frequency stability with little contributions of higher order harmonics. For clinical use, it needs to be compact for comfort as well as interference with RF coil placement. Safe operation in strong electromagnetic fields is a must. Setup procedures should be simple and quick. Here, a new compact pneumatically driven gravitational transducer (CPT) for MR elastography is presented. It consists of rotating unbalances stacked on either side of a turbine. Additional insertable masses allow adjustment of the vibration amplitude at a set frequency. Additive manufacturing and milling were combined to produce the transducer. The flat design of the CPT allows for placement between body and receiver coil with minimal sensitivity loss in most relevant targets. PID control is used to precisely control vibration frequency, based on optical detection of rotation cycles. It adjusts a valve in the air supply of the turbine. It is constructed using non-magnetic, non-conducting materials, which makes it inherently MRI-safe. The electronics, fittings and valves are placed in a control unit (CU) outside the magnet room. A hose and two optical fibres connect the transducer and the CU. The performance of the transducer was thoroughly bench tested and phantom experiments in the MRI scanner demonstrated the feasibility and robustness of the system. The frequency control was excellent for a pneumatic system (FWHM 0.04-0.20 Hz) across a wide range (50-130 Hz), while amplitudes of higher harmonics are very low (1.9-8.1 % 1st, 0.2-4.6 % 2nd order). Imaging data confirm that the CPT generated displacements which could be recorded with MR elastography pulse sequences. In conclusion, we present a new MRE pneumatically driven gravitational transducer, Its advantages are the combination of the following features: It requires no electrical components in the vicinity of the MR scanner. It performs equally well as electromechanically driven systems while it outperforms pneumatic designs in terms of frequency stability. Its compact design allows for flexibility in placement with a variety of RF coils and target tissues in the body. It consists of low-cost components and is easily used. We conclude that the combination of the CPT’s features constitute a substantial improvement in MRE transducer design.

1 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
MKMichael Kusolitsch
Michael Kusolitsch
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
MTMaximilian Thier
Maximilian Thier
JGJean-Lynce Gnanago
Jean-Lynce Gnanago
KSKerstin Schneider-Hornstein
Kerstin Schneider-Hornstein
MHMichael Hofbauer
Michael Hofbauer