Maria Baldini

Dr. Maria Baldini


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
GAGiorgio Ambrosio
Giorgio Ambrosio
KAKathleen Amm
Kathleen Amm
MAMichael Anerella
Michael Anerella
GAGiorgio Apollinari
Giorgio Apollinari
MBMaria Baldini
Maria Baldini
MYMiao Yu
Miao Yu
With the successful test of the first two pre-series magnets the US HL-LHC Accelerator Upgrade Project has started production of the MQXFA magnets to be used in Q1/Q3 inner triplet elements of the HL-LHC. This good start comes after the test of two prototypes with limited performance, and it demonstrates the importance of learning from past issues. Therefore, in this paper we want to share the most important lessons learned so far, focusing on those which may be more interesting for similar projects. We will also present the status of MQXFA fabrication in the US.

31 March 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
GAGiorgio Ambrosio
Giorgio Ambrosio
KAKathleen Amm
Kathleen Amm
MAMichael Anerella
Michael Anerella
GAGiorgio Apollinari
Giorgio Apollinari
GIGonzalo Arnau Izquierdo
Gonzalo Arnau Izquierdo
MYMiao Yu
Miao Yu
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low-beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some of the criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this article, we present a summary of: 1) the fabrication and test data for all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.

8 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
INI. Novitski
I. Novitski
AZAlexander Zlobin
Alexander Zlobin
MBMaria Baldini
Maria Baldini
SKS. Krave
S. Krave
DOD. Orris
D. Orris
EBEmanuela Barzi
Emanuela Barzi
Large-aperture high-field superconducting (SC) magnets are used in various accelerator systems of particle accelerators/colliders. Large Lorentz forces and mechanical stresses can degrade or damage the brittle SC coils. The stress-managed cos-theta (SMCT) coil is a new concept for high-field and/or large-aperture accelerator magnets based on low-temperature and high-temperature superconductors. This concept was proposed and is being developed at Fermilab in the framework of the US Magnet Development Program (US-MDP). The SMCT structure is used to reduce the large coil deformations under Lorentz forces and, thus, the excessively large strains and stresses in the coil. A 120-mm aperture two-layer Nb 3 Sn SMCT dipole coil has been developed at Fermilab to demonstrate the SM concept including coil design, fabrication technology, and performance. The first SMCT demo coil was assembled with a 60-mm aperture Nb 3 Sn coil inside a dipole mirror configuration to be tested separately and in series with the insert coil. This article summarizes the SMCT coil design and parameters, the mirror magnet assembly, and the results of separate SMCT coil test in the dipole mirror configuration.

8 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AZAlexander Zlobin
Alexander Zlobin
INIgor Novitski
Igor Novitski
EBEmanuela Barzi
Emanuela Barzi
MBMaria Baldini
Maria Baldini
JCJustin Carmichael
Justin Carmichael
DTDaniele Turrioni
Daniele Turrioni
In the framework of the U.S. Magnet Development Program (MDP), Fermilab has developed and tested a high-field Nb3Sn dipole demonstrator MDPCT1 for a post-LHC Hadron Collider. The magnet was first assembled with a lower coil pre-load to minimize the risk of coil damage during assembly and test. In the first test the magnet reached its test goal producing a world record field of 14.1 T at 4.5 K. Next the magnet was reassembled with nominal pre-load to achieve its design field limit of 15 T. This paper describes the details of MDPCT1 inspection, design modifications and reassembly. The magnet quench performance, including training, ramp rate and temperature dependences in the temperature range of 1.9-4.5 K, is presented and discussed.

18 March 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JMJoseph F. Muratore
Joseph F. Muratore
KAKathleen Amm
Kathleen Amm
MAMichael Anerella
Michael Anerella
GAGiorgio Ambrosio
Giorgio Ambrosio
GAGiorgio Apollinari
Giorgio Apollinari
PWPeter Wanderer
Peter Wanderer
The future high luminosity (Hi-Lumi) upgrade of the Large Hadron Collider (LHC) at CERN will include eight (plus two spares) 8.4 m-long cryostatted cold masses which will be components of the triplets for two LHC insertion regions. Each cold mass will consist of two 4.2 m long $\text{Nb}_3 \text{Sn}$ high gradient quadrupole magnets, designated MQXFA, with aperture 150 mm and operating gradient 132.6 T/m, for a total of twenty magnets. Before assembling and testing the final cold masses at Fermilab, the twenty component quadrupoles will be tested first at the vertical superconducting magnet test facility of the Superconducting Magnet Division at Brookhaven National Laboratory (BNL), in superfluid He at 1.9 K and to 18.0 kA, to meet LHC operational requirements. The first two full-length prototype quadrupole magnets, MQXFAP1 and MQXFAP2, have been tested at BNL. This paper reports on the quench test and training results of these magnets, and also the retest of the first prototype, rebuilt and designated as MQXFAP1b. The test results of these magnets will be important for validating the MQXFA design.

23 January 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AMAlice Moros
Alice Moros
MCMickael Denis Crouvizier
Mickael Denis Crouvizier
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
SSStefano Sgobba
Stefano Sgobba
SBSusana Izquierdo Bermudez
Susana Izquierdo Bermudez
GVGiorgio Vallone
Giorgio Vallone
The design and production of Nb 3 Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb 3 Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb 3 Sn, the coil fabrication steps are very challenging and require very careful QA/QC. Flaws in the Nb 3 Sn filaments may lead to quenches, and eventually, performance limitation below nominal during magnet testing. A novel inspection method, including advanced non-destructive and destructive techniques, was developed to explore the root-causes of quenches occurring in performance-limiting coils. The most relevant results obtained for MQXF coils through this innovative inspection method are presented. This approach allows for precise assessment of the physical events associated with the quenches experienced by magnet coils, mainly occurring in the form of damaged strands with transversely broken sub-elements. Coil-slice preparation, micro-optical observations of transverse and longitudinal cross-sections, and a deep etching technique of copper will be illustrated in the present work, with a focus on the results achieved for a CERN coil from a non-conforming quadrupole magnet prototype, and two coils fabricated in the US, in the framework of the Accelerator Upgrade Project (AUP) collaboration, from two different non-conforming quadrupole magnets, respectively. The results obtained through the proposed inspection method will be illustrated.