The understanding of coronary artery disease is evolving, with more attention given currently to the microcirculation compartment. Coronary microvascular dysfunction (CMD) is defined by any structural or functional alteration of the coronary microcirculation, and is prevalent in current clinical practice, being associated with pejorative cardiovascular prognosis. CMD can exist by itself as primary microvascular angina, or in association with a variety of cardiovascular diseases. On the other hand, fractional flow reserve (FFR) represents the gold standard for estimating the hemodynamic impact of moderate coronary artery stenosis, and as such guiding coronary revascularization in clinical practice. The fundamental clinical trials that introduced and validated the use of FFR in current clinical practice were published before acquiring more in-depth knowledge on CMD and the impact it can have on FFR measurements. However, in the setting of CMD, studies have shown that FFR can underestimate the severity of coronary stenosis. In addition, recent findings underline the limitations of FFR to guide revascularization in terms of clinical outcome in specific conditions associated with CMD, such as acute coronary syndrome or multivessel coronary artery disease. As such, new research efforts must be made to investigate the reliability of FFR or to reposition its use in guiding coronary revascularization in the context of CMD, in order to define the clinical value of FFR in this particular setting.
Aims: Atrial fibrillation (AF) ablation by pulmonary vein isolation (PVI) and left atrial appendage closure (LAAC) are increasingly performed as standalone procedures. Given that PVI and LAAC share the same access route, a combined approach of pulsed field ablation (PFA)-based PVI and LAAC might be beneficial. The COCONUT study focused on safety, efficacy, and outcomes combining PVI by PFA with LAAC in one procedure. Methods: This is a retrospective, multinational registry study. The primary endpoints were the following: (1) primary safety endpoint: serious adverse events; and (2) primary efficacy endpoint: success of PVI and LAA closure defined as the ability to isolate all pulmonary veins and the successful closure of the LAA. For secondary endpoints, peri-procedural data and follow-up data were collected. Results: A total of 155 patients from 22 centres of nine European countries were treated by concomitant pentaspline catheter PFA-based PVI and LAAC. The mean CHA2DS2-VA score was 3.1 ± 1.4. The primary efficacy endpoint was achieved at 97.4% with successful PVI at 100% and successful LAAC in 151/155 patients (97.4%). The primary safety endpoint was observed in 3/155 patients (1.9%). Transoesophageal echocardiography and/or CCTA 67 ± 26 days after the procedure showed no device embolization and no device-related thrombus, 24/151 (15.9%) patients showed peri-device gaps of 5 mm have been observed in 3/151 (2.0%). Among 137/155 patients with available arrhythmia, a follow-up >6 months at 78.1% showed sinus rhythm. Conclusion: In this large multicentre study, concomitant PFA-based AF ablation and LAA closure proved to be feasible, effective, and safe and overall procedure duration was short.
Background: Left atrial appendage occlusion (LAAO) requires a significant upfront investment, which is in contrast with the more gradual, long-term costs of direct oral anticoagulants (DOACs). Objective: We performed a budget impact analysis exploring the financial impact of increasing the number of LAAO procedures in a high-stroke-risk population over a 10-year time horizon from the perspective of the healthcare providers under the Italian National Healthcare Service. Methods: Two alternative scenarios simulating an increased uptake of the LAAO therapy were compared to the estimated volume of LAAO procedures performed (baseline scenario: 1341 procedures): (1) Alternative Scenario I (3314 procedures) based on the level of penetration observed in the Italian region performing the highest rate of LAAO procedures; (2) Alternative Scenario II (7672 procedures): LAAO therapy uptake set to attain 5% of the estimated target population. Clinical data were extracted from a propensity-matched, multicenter cohort of 554 AF patients at a very high thromboembolic risk profile (CHA2DS2-VASc score ≥ 5) treated with LAAO or DOACs. Results: Cumulative cost savings in Alternative Scenario I were around €4.9 million compared to the baseline. When comparing Scenario II to the baseline scenario, savings added up to €15.8 million over 10 years. The break-even point occurred between the seventh and eighth years. Cost savings were observed even in the instance that all DOAC prices would decrease as generics became available. Conclusions: The widespread use of LAAO therapies in a population of AF patients at very high stroke risk may yield substantial long-term benefits, as the initial investment in the LAAO procedure and device would be counterbalanced within 8 years.
A 74-year-old patient presented to the emergency department with aggravating asthenia and persistent fever over the course of the last 2 weeks. He benefited 3 years prior from a self-expandable transcatheter aortic valve implantation (TAVI) for symptomatic severe aortic valve stenosis, as he refused open heart surgery. The blood workup showed leukocytosis and high C-reactive protein levels. However, the microbiological analysis remained negative. During his hospital stay, a transesophageal echocardiogram was performed, which showed thickening of the transcatheter heart valve leaflets and a vegetation of almost 2 cm attached to the stent of the TAVI. A high suspicion of endocarditis was established at this stage even in the absence of microbiological documentation. Surgery showed extensive damage to the prosthesis and consisted of the careful disengagement of the TAVI followed by a successful aortic valve replacement. The microbiological analysis of the excised TAVI identified Streptococcus bovis as the culprit bacteria. The patient fully recovered at the 1-year follow-up. TAVI endocarditis is a source of emerging new challenges, as they are becoming more frequent due to the increase in TAVI procedures, can affect the leaflets and the stent, and can present destructive evolution even with less aggressive bacteria, while remaining amenable to surgical treatment.