Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan–Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.
22 March 2024 in Journal of Cardiovascular Electrophysiology
Introduction: Limited data exist on pulsed‐field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI).Methods: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM‐PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared.Results: Among 249 patients, 21.7% had long‐standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin‐to‐skin times (PVI‐only 68 [60−90] vs. PVI + LAPWI 70 [59−88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D‐mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh‐density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow‐up of 273 [191–379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90‐day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies.Conclusion: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real‐world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy‐only method and does not significantly extend overall procedural times.
22 November 2012 in Annals of Noninvasive Electrocardiology
Pulsed field ablation (PFA) is an innovative technology recently adopted for the treatment of atrial fibrillation (AF). Preclinical and clinical studies have reported a remarkable safety profile, as a result of its tissue specific effect targeting cardiomyocytes and sparing adjacent tissues. Single-shot pentaspline system was the first PFA device to receive regulatory approval. We performed a meta-analysis to compare the efficacy and safety of PFA with the single-shot pentaspline system versus currently available 2nd/3rd/4th generation Cryoballoon technologies (CRYO). We systematically searched electronic databases for studies focusing on AF ablation employing the PFA single-shot pentaspline system or 2nd/3rd/4th generation CRYO technologies. The primary endpoints were acute procedural success assessed on a vein and patient basis. Safety endpoints included overall periprocedural complications and major periprocedural complications. We also compared procedural, fluoroscopy times, and freedom from atrial tachyarrhythmias (ATs) at follow-up (secondary endpoints). Twenty and 70 studies were included for PFA and CRYO, respectively. PFA demonstrated greater acute procedural success on a vein basis (99.9% vs 99.1%; p<0.001), as well as per patient (99.5% vs 98.4%; p<0.001). PFA yielded lower overall periprocedural complications (3.1% vs 5.6%; p<0.001), shorter procedural time (75.9 min vs 105.6 min; p<0.001) and fluoroscopy time (14.2 min vs 18.9 min; p<0.001) compared to CRYO. No differences were found for major periprocedural complications (1.2% vs 1.0%; p=0.46) and freedom from ATs at 1 year (82.3% vs 80.3%; Log-rank p= 0.61). PFA contributed to higher acute procedural success, and safety compared to CRYO. No statistically significant differences in AT recurrence at 1-year follow-up were observed.
1 August 2023 in Circulation: Arrhythmia and Electrophysiology
BACKGROUND: The analysis of the wave-front activation patterns is crucial for the comprehension and treatment of ventricular tachycardia (VT). The ventricular electrograms duration map (VEDUM) is a potential method to identify areas (VEDUM area) with slow and inhomogeneous activation. There is no available data on the characteristics and the arrhythmogenic role of VEDUM areas identified during sinus/paced rhythm. METHODS: Patients referred for VT ablation were enrolled at 3 different centers. VEDUM maps during sinus/paced rhythm as well as substrate and functional maps were created; activation mapping was performed for all hemodynamically tolerated VT. RESULTS: Thirty-two patients (mean age:70.1±9.4 years; males 93.8%) were enrolled. The VEDUM approach was achieved in all patients and the mean size of the VEDUM area was 12.1±6.9 cm 2 (interquartile range, 7.8–14.9 cm 2 ). A significative difference was observed between the electrogram duration in the VEDUM area and the normal tissue (163.7 ms [interquartile range, 142.3–199.2 ms]; versus 65.5 ms [interquartile range, 59.5–76.2 ms]; P <0.001). The VEDUM area was visualized in a dense scar (<0.5 mV) in 19 (59.4%) patients. A deceleration zone and late potentials were recorded inside the VEDUM area in 56.3% and 81.3%, respectively. When a complete VT activation mapping was available, the isthmus projected in the VEDUM area in 93.5% of patients; 8 of them had multiple VTs mapped and in the 87.5% all VT isthmuses were included in the VEDUM area. CONCLUSIONS: VEDUM maps allow the identification of discrete areas of inhomogeneous and slow conduction. They represent a potential target for VT ablation, including patients with multiple morphologies.