Dario Imbraguglio

Dr. Dario Imbraguglio

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2019 in Metrologia
Verified
Journal Article
Open access
PDF file
RGRoberto Maria Gavioso
Roberto Maria Gavioso
DRDaniele Madonna Ripa
Daniele Madonna Ripa
PSPeter P M Steur
Peter P M Steur
RDRoberto Dematteis
Roberto Dematteis
DIDario Imbraguglio
Dario Imbraguglio
We report speed of sound measurements in helium at 273.16 K and at eight temperatures in the range between 236 K and 430 K. These results determine the difference (T − T 90) between the thermodynamic temperature T and its approximation T 90 by the International Temperature Scale of 1990 (ITS-90). The uncertainty of our measurements of (T − T 90) spans between a minimum of 0.25 mK near 247 K and a maximum of 0.89 mK at the freezing point of indium (429.75 K) with comparable contributions from the uncertainty of our acoustic determination of T and from the uncertainty of our laboratory realization of ITS-90. On the overlapping temperature ranges these results are consistent with other recent acoustic determinations of (T − T 90). We also present evidence that (T − T 90) can be determined with comparably small uncertainties by the alternative, time-saving procedure of measuring the speed-of-sound in helium using only a single, judiciously-chosen, pressure on each isotherm.

3 May 2016 in Physical Chemistry Chemical Physics
Verified
Journal Article
Open access
PDF file
NKNaresh Kumar
Naresh Kumar
SSSteve J. Spencer
Steve J. Spencer
DIDario Imbraguglio
Dario Imbraguglio
ARAndrea Mario ROSSI
Andrea Mario ROSSI
AWAndrew J. Wain
Andrew J. Wain
DRDeb Roy
Deb Roy
Relationship between plasmonic lifetime of tip-enhanced Raman spectroscopy probes and environments with different oxygen and moisture content is investigated systematically.

2 February 2021 in Metrologia
Verified
Journal Article
Open access
PDF file
DRDaniele Madonna Ripa
Daniele Madonna Ripa
DIDario Imbraguglio
Dario Imbraguglio
CGChristof Gaiser
Christof Gaiser
PSPeter P M Steur
Peter P M Steur
DGDomenico Giraudi
Domenico Giraudi
RGRoberto Maria Maria Gavioso
Roberto Maria Maria Gavioso
We have measured the refractive index of helium using a quasi-spherical copper microwave resonator at five different temperatures in the interval between the triple point of hydrogen at 13.8 K and the triple point of xenon at 161.4 K for pressures up to 380 kPa. From these results and additional measurements of the refractive index of neon near 54.4 K, 83.8 K and 161.4 K we determine the differences (T − T 90) between the thermodynamic temperature T and its approximation T 90 by the International Temperature Scale of 1990 (ITS-90). We have estimated the isothermal compressibility of copper and the effective compressibility of our microwave resonator by different methods including resonant ultrasound spectroscopy (RUS) and microwave measurements with helium at 273.16 K. We compare the results of these compressibility estimates and discuss the associated uncertainty. From the refractive index measurements, we estimate the second density virial coefficient of helium and neon which are found in good agreement with the ab initio calculations of the same properties.

9 July 2021 in Metrologia
Verified
Journal Article
Open access
CPChangzhao Pan
Changzhao Pan
FSFernando Sparasci
Fernando Sparasci
HZHaiyang Zhang
Haiyang Zhang
PGPascal Gambette
Pascal Gambette
MPMark Plimmer
Mark Plimmer
LPLaurent Pitre
Laurent Pitre
We used absolute primary acoustic gas thermometry (AGT) to calibrate a Pt–Co resistance thermometer on the thermodynamic temperature scale by measuring the speed of sound in helium at a temperature T* chosen to be near the temperature of the triple point of neon, T Ne. Prior to the present AGT, the Pt–Co thermometer was used with a neon triple-point cell as part of an interlaboratory comparison. Taken together, the results of the interlaboratory comparison and the present AGT redetermined the thermodynamic temperature T Ne = (24.555 15 ± 0.000 24) K. This new value of T Ne is consistent with other recent determinations obtained with various primary methods. After completing the AGT thermodynamic calibration, we used the Pt–Co thermometer to link T* to the temperature ratios measured by single-pressure refractive-index gas thermometry (SPRIGT) in a different laboratory. (Gao et al 2020 Metrologia 57 065006) Now, the T*-linked SPRIGT system can calibrate other thermometers on the thermodynamic temperature scale T in the range 5 K ⩽ T ⩽ T Ne without using the international temperature scale ITS-90. At most temperatures in this range, the uncertainties of the T*-linked SPRIGT system are smaller than those of the ITS-90 systems used by National Metrology Institutes to calibrate resistance thermometers.

16 March 2011 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
Luca BoarinoLuca Boarino
Luca Boarino
DIDario Imbraguglio
Dario Imbraguglio
EEEmanuele Enrico
Emanuele Enrico
NLNatascia De Leo
Natascia De Leo
FCFederica Celegato
Federica Celegato
GAGiampiero Amato
Giampiero Amato

25 October 2021 in Metrologia
Verified
Journal Article
Open access
PDF file
DRD Madonna Ripa
D Madonna Ripa
DIDario Imbraguglio
Dario Imbraguglio
CGC Gaiser
C Gaiser
PSP P M Steur
P P M Steur
DGD Giraudi
D Giraudi
RGR M Gavioso
R M Gavioso