The CERN-RD50 CMOS working group develops the RD50-MPW series of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structures implemented in the chip and the problems they aim to solve. The main analogue and digital features of the sensor are already tested and initial laboratory characterisation of the chip is presented.
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.
13 September 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
To enhance the spatial resolution of the MÖNCH 25 µm pitch hybrid pixel detector, deep learning models have been trained using both simulation and measurement data. Challenges arise when comparing simulation-based deep learning models to measurement-based models for electrons, as the spatial resolution achieved through simulations is notably inferior to that from measurements. Discrepancies are also observed when directly comparing X-ray simulations with measurements, particularly in the spectral output of single pixels. These observations collectively suggest that current simulations require optimization. To address this, the dynamics of charge carriers within the silicon sensor have been studied using Monte Carlo simulations, aiming to refine the charge transport modeling. The simulation encompasses the initial generation of the charge cloud, charge cloud drift, charge diffusion and repulsion, and electronic noise. The simulation results were validated with measurements from the MÖNCH detector for X-rays, and the agreement between measurements and simulations was significantly improved by accounting for the charge repulsion.