Jana Šandrejová

Dr. Jana Šandrejová

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
YBY. Bazel
Y. Bazel
ATA. Tupys
A. Tupys
YOY. Ostapiuk
Y. Ostapiuk
OTO. Tymoshuk
O. Tymoshuk
JIJ. Imrich
J. Imrich
JŠJana Šandrejová
Jana Šandrejová
This work introduces two new thiazolylazo dyes 1-[(5-benzyl-1,3-thiazol-2-yl)diazenyl]naphthalene-2-ol (BnTAN) and 1-[5-(4-sulfonamidobenzyl-4-methyl-1,3-thiazol-2-yl)diazenyl]naphthalen-2-ol (SABnMeTAN) as possible reagents for spectrophotometric determination of copper(II) in water samples in the form of a chelate complex. The substances were synthesized for the first time and characterized using the NMR technique. The main characteristics of ligands, such as molar absorption coefficients and protonation constants, were evaluated spectrophotometrically. A non-extractive sequential injection spectrophotometric method for the determination of copper(II) in the presence of Triton X-100 was developed. The linear range of the calibration plot was observed from 0.063 to 1.270 mg L−1 and the detection limit was 0.044 mg L−1. The SIA method was compared with the respective manual method and applied for the determination of copper(II) in tap and river water.

1 January 2016 in TURKISH JOURNAL OF CHEMISTRY
Verified
Journal Article
Open access
TATatiana Antolová
Tatiana Antolová
SZSerhii Zaruba
Serhii Zaruba
JŠJana Šandrejová
Jana Šandrejová
LKL'ıVia Kocurová
L'ıVia Kocurová
Andriy VishnikinAndriy Vishnikin
Andriy Vishnikin
IBIoseph S. Balogh
Ioseph S. Balogh

Verified
Journal Article
Open access
PDF file
AGAndrea Gajdošová
Andrea Gajdošová
PRPetya Racheva
Petya Racheva
Denitsa Dimitrova KiradzhiyskaDenitsa Dimitrova Kiradzhiyska
Denitsa Dimitrova Kiradzhiyska
VDVidka Vassileva Divarova
Vidka Vassileva Divarova
ASAntoaneta Saravanska
Antoaneta Saravanska
Kiril Blazhev GavazovKiril Blazhev Gavazov
Kiril Blazhev Gavazov
A novel, environmentally friendly cloud point extraction (CPE) method based on 4-nitrocatechol (H2L) was developed in this study to spectrophotometrically determine trace vanadium. This method utilizes a mixed micelle-mediated system comprising a cationic surfactant (cetylpyridinium chloride, CPC) and a nonionic surfactant (Triton X-114). In contrast to conventional CPE, the present approach does not employ centrifugation to separate the two phases. The distinguishing characteristic of the extracted species, (CP+)[VVOL2], is its ability to absorb light across the entire visible spectrum. The measurement at 670 nm, where the complex displays a local maximum, is advantageous for two primary reasons. Firstly, the blank exhibits virtually no absorption, a property that engenders stable and reproducible results. Secondly, selectivity is high because almost all other metal complexes have absorption bands at shorter wavelengths. The proposed method has the following characteristics: a linear range of 2–305 ng mL−1, a limit of detection of 0.6 ng mL−1, a molar absorptivity coefficient of 1.22 × 105 M−1 cm−1, a Sandell sensitivity of 0.42 ng cm−2, and a blue applicability grade index (BAGI) of 67.5. Its efficacy was demonstrated in the analysis of mineral water, a spent vanadium-containing catalyst, and a dietary supplement.

16 June 2025 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
JŠJana Šandrejová
Jana Šandrejová
AGAndrea Gajdošová
Andrea Gajdošová
RSRastislav Serbin
Rastislav Serbin
IBIoseph Balogh
Ioseph Balogh
This article highlights a new approach for liquid–liquid microextraction, which takes into account the possibility of using one flow-based system for various automated microextraction modes. This design for the microextraction process in combination with an optical probe was proposed and successfully tested for dispersive liquid–liquid microextraction (DLLME), air-assisted dispersive liquid–liquid microextraction (AA-DLLME) and magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) of nitrate. The results showed that the proposed system is simple and enables an easy change of the operation protocol. The system was applied to the determination of NO3 − in the form of an ion associate with the malachite green reagent. Under optimized conditions, the best sensitivity of determination was achieved by MSA-DLLME. The calibration graph was linear over the concentration range of 0.2–10 mg L−1 NO3 −. The LOD was 0.008 mg L−1 NO3 −. The procedure was applied to the determination of nitrate in vegetable and water samples. The applied procedure was compared with ion chromatography approaches and evaluated using metrics, including the Analytical Greenness Metric Approach (AGREE) for greenness, the most current Blue Applicability Grade Index (BAGI) for blueness, and the more inclusive RGB 12 algorithm for whiteness assessment. The evaluation shows high overall scores for the presented procedure.

Verified
Journal Article
Open access
PDF file
AGAndrea Gajdošová
Andrea Gajdošová
PRPetya Racheva
Petya Racheva
ASAntoaneta Saravanska
Antoaneta Saravanska
JŠJana Šandrejová
Jana Šandrejová
Kiril Blazhev GavazovKiril Blazhev Gavazov
Kiril Blazhev Gavazov
A novel centrifuge-less cloud-point extraction (CL-CPE) method based on pyrogallol (PG) was developed for the spectrophotometric determination of total vanadium. The method employs a mixed micelle-mediated extraction system comprising the nonionic surfactant Triton X-114 and the ionic liquid Aliquat 336 (A336), which serves as a source of monovalent cations capable of forming an ion pair with the anionic vanadium–PG chelate. The extracted species, (A336+)[VIV(OH)(PG)2], exhibits several absorption maxima (309, 362, and 436 nm), providing enhanced selectivity through appropriate wavelength selection according to the sample matrix. The principal absorption maximum occurs at 309 nm. At a sevenfold preconcentration factor, the method provides high sensitivity at this wavelength, with a molar absorptivity of 3.2 × 107 L mol−1 cm−1, a limit of detection of 0.11 ng mL−1, and a Sandell sensitivity of 1.6 × 10−3 ng cm−2. The applicability of the method was demonstrated through the analysis of drinking water samples, spent vanadium catalyst materials, and vanadium-containing dietary supplements. The method was further evaluated using the RGBfast model, a white analytical chemistry assessment tool that integrates analytical performance, environmental sustainability, and practical and economic efficiency. The evaluation indicated a high overall whiteness score.

22 September 2026 in Molecules
Verified
Journal Article
Open access
PDF file
PRPetya Racheva
Petya Racheva
ASAntoaneta Saravanska
Antoaneta Saravanska
AGAndrea Gajdošová
Andrea Gajdošová
Kirila Trifonova StoynovaKirila Trifonova Stoynova
Kirila Trifonova Stoynova
VDVassil Delchev
Vassil Delchev
Kiril Blazhev GavazovKiril Blazhev Gavazov
Kiril Blazhev Gavazov
The ability of 3,5-dinitrocatechol (3,5-DNC) to form anionic species with vanadium(V) in a mildly acidic medium was exploited to develop a spectrophotometric method for vanadium determination. The method is grounded on the formation of an ion-association complex with benzalkonium chloride (BAC), which is efficiently extracted into a surfactant-rich phase formed in a mixed micellar medium consisting of Triton X-114 and BAC. The stoichiometry of the extracted complex was established as (BA+)[VO(3,5-DNC)2], and the formula of its anionic component, [VO(3,5-DNC)2]−, was verified by quantum-chemical calculations at the B3LYP/6-311G level of theory and by comparison of the experimental absorption spectrum with simulated theoretical spectra. The results indicate that the thermodynamically more stable anti isomer is preferentially formed and extracted. The developed novel centrifuge-less cloud point extraction–spectrophotometric method exhibits an absorption maximum at 426 nm, an apparent molar absorptivity of 1.6 × 106 L mol−1 cm−1, a limit of detection of 1.7 ng mL−1, and a linear range of 5.7–29.1 ng mL−1. The method was successfully applied to the determination of vanadium in spent catalysts and vanadium-based dietary supplements. Its analytical performance and sustainability were evaluated using modern assessment tools, including RGBfast.