Siti Azlida Ibrahim

Dr. Siti Azlida Ibrahim


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Optics & Laser Technology
Verified
Journal Article
Open access
YRY.M. Raji
Y.M. Raji
HLH.S. Lin
H.S. Lin
SISiti Azlida Ibrahim
Siti Azlida Ibrahim
MMMohd Ridzuan Mokhtar
Mohd Ridzuan Mokhtar
ZYZulfadzli Yusoff
Zulfadzli Yusoff
An abrupt tapered fiber In-Line Mach-Zehnder Interferometer sensor for simultaneous measurement of temperature and curvature is proposed and experimentally demonstrated. The sensor head is fabricated by arcing Corning SMF-28 using a commercial arc fusion splicer. The individual parameters discrimination was achieved by manipulating the unequal sensitivities of optical power to temperature and curvature obtained at two wavelengths within the sensing spectrum. The curvature and temperature sensitivities at λ1 (1537 nm) and λ2 (1568.7 nm) were found to be 11.8264 dBm/m−1, 12.4885 dBm/m−1 and 0.0829 dBm/°C, 0.0833 dBm/°C, respectively. The experimental results show unperturbed readings with rms deviation of ±0.1801 m−1 and ±0.0826 °C, for curvature and temperature measurements, respectively, through measurement of optical power response of the sensor. With this simultaneous sensing technique, the proposed sensor can be deployed for many field applications such as nondestructive structural health monitoring of civil infrastructure.

14 August 2023 in IEEE Access
Verified
Journal Article
Open access
SMSiti Musliha Aishah Musa
Siti Musliha Aishah Musa
MDMohd Haziq Dzulkifli
Mohd Haziq Dzulkifli
AAAsrul Izam Azmi
Asrul Izam Azmi
SISiti Azlida Ibrahim
Siti Azlida Ibrahim
Fiber-reinforced plastic (FRP) composites are utilized extensively in various high-end industries. Therefore, developing a proper sensing and monitoring system is crucial to monitor the production and post-production in-service structural behaviors of composite materials. This paper provides a comprehensive literature review focusing on Fiber Bragg Grating (FBG) as a multiparameter sensor in FRP composite materials. The review is mainly divided into two main themes, namely, embedded FBGs and surface-attached FBGs, followed by further sub-themes according to the application of the FBGs. Contemporary issues regarding FBGs as sensors in composite materials are also discussed. Subsequently, a comparative analysis between the embedded and surface-attached techniques from various perspectives is presented before further recommendation for the ideal embedding conditions and techniques is provided. This review is summarized with a projected view on the future of FBGs as a sensor, generally, and in composite laminates, specifically.

26 February 2015 in Sensors
Verified
Journal Article
Open access
PDF file
ZYZainab Yunusa
Zainab Yunusa
MHMohd Hamidon
Mohd Hamidon
Alyani IsmailAlyani Ismail
Alyani Ismail
MIMaryam Isa
Maryam Isa
MYMohd Yaacob
Mohd Yaacob
ASArafat Shabaneh
Arafat Shabaneh
A double SAW resonator system was developed as a novel method for gas sensing applications. The proposed system was investigated for hydrogen sensing. Commercial Surface Acoustic Wave (SAW) resonators with resonance frequencies of 433.92 MHz and 433.42 MHz were employed in the double SAW resonator system configuration. The advantages of using this configuration include its ability for remote measurements, and insensitivity to vibrations and other external disturbances. The sensitive layer is composed of functionalized multiwalled carbon nanotubes and polyaniline nanofibers which were deposited on pre-patterned platinum metal electrodes fabricated on a piezoelectric substrate. This was mounted into the DSAWR circuit and connected in parallel. The sensor response was measured as the difference between the resonance frequencies of the SAW resonators, which is a measure of the gas concentration. The sensor showed good response towards hydrogen with a minimum detection limit of 1%.

1 June 2016 in Electronics Letters
Verified
Journal Article
Open access
PDF file
SISiti Azlida Ibrahim
Siti Azlida Ibrahim
ARA.H. Ridzwan
A.H. Ridzwan
Amilia MansoorAmilia Mansoor
Amilia Mansoor
KDK.D. Dambul
K.D. Dambul
This Letter reports a lead (II) ion sensor composed of a tapered multimode fibre (MMF) coated with chitosan. The diameter and length of the tapered fibre region is 20 µm and 1 cm, respectively. Tapered MMF is used because it is more flexible and compact compared with plastic clad silica. Chitosan is chosen as the sensing layer because it can absorb heavy metal ions due to its unique properties as polyelectrolyte and chelating agent. The refractive index of the chitosan layer changes as it absorbs lead (II) ion and this leads to an increase in the absorbance measured by the spectrophotometer. This is tested by immersing the sensor in a solution that contains lead (II) ion with different concentrations, from 0.2 to 1 ppm. The results show that the absorbance measured by the spectrophotometer increased as the concentration of the lead (II) ion increased. The sensor's average sensitivity is measured as 40.554 abs/ppm. This sensor is simpler compared with surface plasmon resonance‐based lead (II) ion sensor because it does not require metal coating prior to the sensing layer coating.

7 April 2022 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
HZH.T. Zubair
H.T. Zubair
AOAdebiyi Oresegun
Adebiyi Oresegun
Auwal AbubakarAuwal Abubakar
Auwal Abubakar
ABAzmi Basaif
Azmi Basaif
HZHafiz Zin
Hafiz Zin
DBDAVID BRADLEY
DAVID BRADLEY
The quality of treatment delivery as prescribed in radiotherapy is exceptionally important. One element that helps provide quality assurance is the ability to carry out time-resolved radiotherapy dose measurements. Reports on doped silica optical fibers scintillators using radioluminescence (RL) based radiotherapy dosimetry have indicated merits, especially regarding robustness, versatility, wide dynamic range, and high spatial resolution. Topping the list is the ability to provide time-resolved measurements, alluding to pulse-by-pulse dosimetry. For effective time-resolved dose measurements, high temporal resolution is enabled by high-speed electronics and scintillator material offering sufficiently fast rise and decay time. In the present work, we examine the influence of Ge doping on the RL response of Ge-doped silica optical fiber scintillators. We particularly look at the size of the Ge-doped core relative to the fiber diameter, and its associated effects as it is adjusted from single-mode fiber geometry to a large core-to-cladding ratio structure. The primary objective is to produce a structure that facilitates short decay times with a sufficiently large yield for time-resolved dosimetry. RL characterization was carried out using a high-energy clinical X-ray beam (6 MV), delivered by an Elekta Synergy linear accelerator located at the Advanced Medical and Dental Institute, Universiti Sains Malaysia (USM). The Ge-doped silica optical fiber scintillator samples, fabricated using chemical vapor deposition methods, comprised of large core and small core optical fiber scintillators with high and low core-to-cladding ratios, respectively. Accordingly, these samples having different Ge-dopant contents offer distinct numbers of defects in the amorphous silica network. Responses were recorded for six dose-rates (between 35 MU/min and 590 MU/min), using a photomultiplier tube setup with the photon-counting circuit capable of gating time as small as 1 μs. The samples showed linear RL response, with differing memory and afterglow effects depending on its geometry. Samples with a large core-to-cladding ratio showed a relatively short decay time (<1 ms). The results suggest a contribution of Ge-doping in affecting the triplet states of the SiO2 matrix, thereby reducing phosphorescence effects. This is a desirable feature of scintillating glass materials that enables avoiding the pulse pile-up effect, especially in high dose-rate applications. These results demonstrate the potential of Ge-doped optical-fiber scintillators, with a large core-to-cladding ratio for use in time-resolved radiation dosimetry.

17 September 2012 in Wireless Personal Communications
Verified
Journal Article
Closed access
PDF file
SISiti Azlida Ibrahim
Siti Azlida Ibrahim
MAMohamad Yusoff Alias
Mohamad Yusoff Alias
NANurul Nadia Ahmad
Nurul Nadia Ahmad