Background: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bioprostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. Methods: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. Results: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. Conclusions: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04500964.
The aim of the present analysis is to compare the quantitative angiographic aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) among three balloon-expandable valves. Quantitative videodensitometric aortography is an objective, accurate, and reproducible tool for adjudication of AR following TAVI. This is a retrospective corelab analysis, independent from industry, of aortograms from patients treated with TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., India), Sapien 3, and XT THVs (Edwards Lifesciences, Irvine, CA, USA). The study comprised of 108 analyzable aortograms from consecutive patients in a multicenter European registry who underwent Myval THV implantation. The results of quantitative assessment of AR in the Sapien 3 THV (n = 397) and Sapien XT THV (n = 239) were retrieved from a published pooled database. The Myval THV had the lowest proportion of patients with moderate or severe angiographic quantitative AR (2.8%) compared to the Sapien 3 THV (8.3%; p = 0.049) and Sapien XT THV (10.9%; p = 0.012). Furthermore, the Myval THV had the lowest mean angiographic quantitative AR (6.3 ± 6.3%), followed by Sapien 3 THV (7.6 ± 7.1%) and Sapien XT THV (8.8 ± 7.5%), and it was significantly lower than that of the Sapien XT THV (p = 0.006), but not significantly different from Sapien 3 THV (p = 0.246). The Myval THV, in comparison with other BEV’s analyzed in our database, showed a lower occurrence of moderate or severe AR after TAVI. These results should be confirmed in prospective cohorts of randomized patients with head-to-head THV comparisons.
1 January 2017 in International Journal of Cardiology
There is increasing evidence that genetic variability influence patients’ early morbidity after cardiac surgery performed using cardiopulmonary bypass (CPB). The use of mortality as an outcome measure in cardiac surgical genetic association studies is rare. We publish the 30-day and 5-year survival analyses with focus on pre-, intra-, postoperative variables, biochemical parameters, and genetic variants in the INFLACOR (INFlAmmation in Cardiac OpeRations) cohort.In a series of prospectively recruited 518 adult Polish Caucasians who underwent cardiac surgery in which CPB was used, the clinical data, biochemical parameters, IL-6, soluble ICAM-1, TNFa, soluble E-selectin, and 10 single nucleotide polymorphisms were evaluated for their associations with 30-day and 5-year mortality.The 30-day mortality was associated with: pre-operative prothrombin international normalized ratio, intra-operative blood lactate, postoperative serum creatine phosphokinase, and acute kidney injury requiring renal replacement therapy (AKI-RRT) in logistic regression. Factors that determined the 5-year survival included: pre-operative NYHA class, history of peripheral artery disease and severe chronic obstructive pulmonary disease, intra-operative blood transfusion; and postoperative peripheral hypothermia, myocardial infarction, infection, and AKI-RRT in Cox regression. The serum levels of IL-6 and ICAM-1 measured three hours after operation were associated with 30-day and 5-year mortality, respectively. The ICAM1 rs5498 was associated with 30-day and 5-year survival with borderline significance.Different risk factors determined the early (30-day) and late (5-year) survival after adult cardiac surgery in which cardiopulmonary bypass was used. Future genetic association studies in cardiac surgical patients should adjust for the identified chronic and acute postoperative risk factors.
Background: There is still a lack of data on the nutritional status of older people with aortic stenosis (AS) and the effect of poor nutrition on the occurrence of complications and mortality after an aortic valve replacement (AVR) procedure. The aim of this study was to assess the impact of selected nutritional status parameters in elderly patients with severe AS on the occurrence of postoperative complications and one-year mortality after the AVR procedure. Methods: 101 elderly patients with AS aged 74.6 ± 5.2 years who qualified for surgical treatment (aortic valve area [AVA] 0.73 ± 0.2 cm2) were enrolled in the study. A nutritional status assessment was performed before AVR surgery, and the frequency of postoperative complications occurring within 30 days of surgery was assessed. The one-year mortality rate was also captured. Results: Adverse events (both major and minor) up to 30 days occurred in 49.5% (n = 50) of the study population. Low Mini Nutritional Assessment (f-MNA) and Subjective Global Assessment (7-SGA) scores and low concentrations of total cholesterol, LDL-cholesterol, and prealbumin were associated with a higher risk of postoperative complications. The risk of complications increased 1.22 times (95% CI; 1.030–1.453; p = 0.019) with an impaired nutritional status. The annual mortality rate in the study group was 7.9%. Unintentional weight loss of >2.8% in the six months preceding surgery proved useful for predicting death within the first year after AVR surgery. Conclusions: The results indicate that poor nutritional status is an important factor affecting the adverse outcomes in elderly patients with severe aortic valve stenosis undergoing an AVR procedure.
Transaortic transcatheter aortic valve implantation (TAo-TAVI) is a recently developed approach that provides an alternative delivery route for valve replacement in patients with vascular abnormalities or existing comorbidities. While initial studies have shown the principal efficacy and safety, the real world effectiveness and safety of this approach remains to be fully assessed. In this regard, the Registry Of the Utilization of the TAo-TAVI approach using the Edwards SAPIEN Valve (ROUTE) represents the first multicenter, multinational prospective documentation of the course and outcome of patients with severe calcific aortic stenosis (AS) undergoing TAo-TAVI. ROUTE commenced in February 2013 with the goal of consecutively enrolling 300 patients at up to 22 sites across Europe. The primary objective of ROUTE is to determine the 30-day mortality associated with TAo-TAVI using the Edwards SAPIEN THV (Edwards Lifesciences, Irvine, CA). In addition, ROUTE aims to quantify complications, predictors of patient outcome and the value of CT guided valve sizing. Findings from this landmark registry will provide important information regarding procedural success rates and early mortality in patients undergoing TAo-TAVI. Identifier: NCT01991431 .