Darren Mylotte

Dr. Darren Mylotte


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
FMFederico Mercanti
Federico Mercanti
LRLiesbeth Rosseel
Liesbeth Rosseel
ANAntoinette Neylon
Antoinette Neylon
RBRodrigo Bagur
Rodrigo Bagur
JSJan-Malte Sinning
Jan-Malte Sinning
DMDarren Mylotte
Darren Mylotte

1 February 2013 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
DMDarren Mylotte
Darren Mylotte
MMMarie-Claude Morice
Marie-Claude Morice
HEHélène Eltchaninoff
Hélène Eltchaninoff
JGJérôme Garot
Jérôme Garot
YLYves Louvard
Yves Louvard
PGPhilippe Garot
Philippe Garot

20 June 2022 in Nature Reviews Cardiology
Verified
Journal Article
Closed access
PDF file
TXTian-Yuan Xiong
Tian-Yuan Xiong
WAWalid Ben Ali
Walid Ben Ali
YFYuan Feng
Yuan Feng
KHKentaro Hayashida
Kentaro Hayashida
HJHasan Jilaihawi
Hasan Jilaihawi
DMDarren Mylotte
Darren Mylotte

1 September 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
ODOspedale dell'Angelo
Ospedale dell'Angelo
GGGuglielmo Gallone
Guglielmo Gallone
WKWon-Keun Kim
Won-Keun Kim
JRJoerg Reifart
Joerg Reifart
VVVerena Veulemans
Verena Veulemans
FGFrancesco Giannini
Francesco Giannini
Background: An increased degree of aortic angulation (AA) represents a challenging feature for bioprosthesis positioning. Whether AA has an impact on procedural outcomes of contemporary self-expanding valves remains unsettled. The aim of this study was to evaluate the impact of AA on procedural outcomes of transcatheter aortic valve replacement with contemporary self-expanding valves. Methods: The HORSE (Horizontal Aorta in Transcatheter Self-Expanding Valves) is an international, retrospective registry including 3862 consecutive patients undergoing transcatheter aortic valve replacement with either Evolut R/PRO (n=1959) or ACURATE neo (n=1903) devices. Patients undergoing Evolut R 34 mm implantation were excluded as no comparable prosthesis size for ACURATE neo is available. AA was evaluated with preprocedural computed tomography, and its impact on device success was evaluated. Results: In the overall population, AA did not have any impact upon device success, also when adjusting for in-study outcome predictors (odds ratio for 1° increment, 0.99 [95% CI, 0.98–1.01], P =0.306). However, increased AA was associated with lower device success with use of the Evolut R/PRO valves (odds ratio, 0.97 [95% CI, 0.95–0.99]; P =0.004), but not the ACURATE neo valves (odds ratio, 1.00 [95% CI, 0.98–1.03], P =0.304). The best AA cutoff value predicting device success was 49° (47% of the study cohort). Among patients with AA≥49°, Evolut R/PRO valves were associated with lower device success as compared to the ACURATE neo valve (inverse probability weighting odds ratio, 0.62 [95% CI, 0.46–0.83]; P =0.002). Conclusions: Horizontal aorta, as defined by an AA ≥49°, is a common feature among transcatheter aortic valve replacement candidates and predicts device failure of the Evolut R/PRO valves, but not of the ACURATE neo valve. AA may be an effect modifier of the association between self-expanding valve type and device success.

15 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AEAhmed Elkoumy
Ahmed Elkoumy
JJJohn Jose
John Jose
CTchristian juhl terkelsen
christian juhl terkelsen
HNhenrik nissen
henrik nissen
SGSengottuvelu Gunasekaran
Sengottuvelu Gunasekaran
OSOsama Soliman
Osama Soliman
Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI’s procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.

19 March 2021 in Global Heart
Verified
Journal Article
Open access
PDF file
HKHideyuki Kawashima
Hideyuki Kawashima
KLKun Lian
Kun Lian
DMDarren Mylotte
Darren Mylotte
DJDariusz Jagielak
Dariusz Jagielak
Federico De MarcoFederico De Marco
Federico De Marco
OSOsama Soliman
Osama Soliman
The aim of the present analysis is to compare the quantitative angiographic aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) among three balloon-expandable valves. Quantitative videodensitometric aortography is an objective, accurate, and reproducible tool for adjudication of AR following TAVI. This is a retrospective corelab analysis, independent from industry, of aortograms from patients treated with TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., India), Sapien 3, and XT THVs (Edwards Lifesciences, Irvine, CA, USA). The study comprised of 108 analyzable aortograms from consecutive patients in a multicenter European registry who underwent Myval THV implantation. The results of quantitative assessment of AR in the Sapien 3 THV (n = 397) and Sapien XT THV (n = 239) were retrieved from a published pooled database. The Myval THV had the lowest proportion of patients with moderate or severe angiographic quantitative AR (2.8%) compared to the Sapien 3 THV (8.3%; p = 0.049) and Sapien XT THV (10.9%; p = 0.012). Furthermore, the Myval THV had the lowest mean angiographic quantitative AR (6.3 ± 6.3%), followed by Sapien 3 THV (7.6 ± 7.1%) and Sapien XT THV (8.8 ± 7.5%), and it was significantly lower than that of the Sapien XT THV (p = 0.006), but not significantly different from Sapien 3 THV (p = 0.246). The Myval THV, in comparison with other BEV’s analyzed in our database, showed a lower occurrence of moderate or severe AR after TAVI. These results should be confirmed in prospective cohorts of randomized patients with head-to-head THV comparisons.