This paper is focusing on Particulate Matter (PM10) as the one of the main pollutants in the urban environments, and the one of the main sources of PM emissions are small household furnaces. This paper shows a part of the results of the research related to measurements of the ambient concentrations of aerosols and definition of the sources of the pollution in one part of Banja Luka city area, with dominant private households. Spatial and seasonal variability of concentrations indicates a significant contribution of biomass and fossil fuel burning as well as specific meteorological conditions. By using positive matrix factorization, (PMF) technique chemical composition data for PM10 were analysed in order to identify the possible sources and estimate their contribution to particulate matter mass. A biomass combustion devices were identified as the one of dominant PM10 emission sources during the winter season, because highly determined correlation between PM10 and potassium content. From the other side, the results of the project “Typology of Residential Buildings in Bosnia and Herzegovina”, were used as a tool for prediction and quantification of influence of the household’s appliances on the pollution as well as for definition of the possible measures for reduction for this specific location. This approach took in consideration spatial distribution of buildings, but also their type, which can give the opportunity to estimate their present energy needs and predict improvements, which can lead to reduction of the PM10 pollution at the end. On that base, some recommendations for the improvements were analysed.
10 April 2023 in Environmental Progress & Sustainable Energy
Biomass as Potential Sustainable Development Driver – Case of Bosnia and Herzegovina | InTechOpen, Published on: 2013-04-30. Authors: Petar Gvero, Semin Petrovic, Sasa Papuga, et
Energy saving potentials related to steam generation and its usage in the medium size bakery are analyzed and presented. Input data needed for the investigation are gathered through detailed energy audit. Four energy savings measures are analysed in detail: 1) change of heat generator for space heating and domestic hot water preparation from steam boiler to condensing boiler, 2) reduction of heat losses from steam and condensate distribution lines, 3) heat utilization of return condensate and 4) replacement of the old, low efficiency steam boiler with high-efficient one. Implementation of these measures will result in substantial reduction of energy costs, ranging from 2.900 to 26.200 € annually. Interaction of all measures is analysed through energy efficiency improvement scenario, whose implementation will ensure significant energy cost savings, estimated at 40.793 € annually, with simple payback period shorter than 4 years. Implementation of presented measures will improve facility’s energy efficiency, represented through reduction of annual energy performance indicators by 6,14 %. Presented analysis revealed that steam generation and its usage in the industrial facilities offer a substantial potential for reduction of energy use and energy related cost.
In the subject area, the term nZEB standard appears in 2011 in the legislative framework, but it never came to life, nor in the construction of new buildings, and completely unknown in the renovation of buildings. The reasons for this are insufficiently researched possibilities, i.e., unanalysed energy savings and economic profitability during the building renovation according to the valid regulations and the nZEB standard. This research analysed a specific type of building, a kindergarten, which must also respect the rules and does not have its own classification related to energy classes. Analysis has shown that, depending on the type of building, all possibilities for improving construction should be explored, not only in energy but also in redesign shape, since in this way, it is possible to reduce energy consumption to a minimum.