Grid-forming (GFM) converters facilitate voltage and frequency stability in grids with high penetration of inverter-based renewable energy technologies. Under nominal conditions, the primary function of GFM converters is to control the output voltage by operating in voltage-source mode (VSM). During off-nominal conditions, especially in the presence of severe grid disturbances, the primary objective is to ensure accurate and fast-response current limiting to protect the GFM converter from overcurrents by operating in current-source mode (CSM). A wide stability margin of the inner loops must be guaranteed in nominal and contingency conditions due to the high variability of scenarios that a GFM converter may encounter. This article proposes a double-loop controller with current-limiting capability for GFM converters, ensuring good GFM performance in stand-alone and grid-connected scenarios, including those with very weak and stiff grids. Additionally, the proposed controller provides an enhanced current-limiting response with precise current control during faults. Finally, the proposed controller demonstrates a wide stability range in both VSM and CSM modes. This is experimentally validated through tests of GFM performance in very weak and stiff grids, with sudden changes in the short-circuit ratio, as well as through current-limiting tests under grid-voltage bolted faults conducted across different grid-impedance conditions.
30 April 2025 in IEEE Transactions on Power Electronics
This article introduces an impedance model for a grid-forming (GFM) converter with droop control (Droop-GFM converter) connected to a weak power grid. The proposed model offers a more accurate and simpler alternative to the conventional minor-loop criterion and the generalized Nyquist stability criterion for studying the stability of a Droop-GFM converter, as it accounts for loading effects and uses only two transfer functions. Formulated in the $\alpha \beta$ frame, the model consists of only two balanced impedances, offering a clearer physical interpretation of the impedance asymmetry introduced by droop control, in contrast to dq-frame impedance matrix models. The model describes frequency coupling effects (the mirror frequency problem) across the entire frequency range, providing both a geometric and physical understanding of this phenomenon. It allows determination of the bandwidth of the frequency coupling region, and how this region changes based on the droop coefficients and the loading condition of the Droop-GFM converter. The theoretical findings are validated experimentally using a Droop-GFM converter in three distinct scenarios, including: weak power grid operation, a change in the droop coefficients, and a change in the power grid impedance.
28 November 2024 in IEEE Transactions on Power Electronics
Voltage-controlled voltage-source inverters with an output LC-filter are used in a wide variety of power supply applications. LC-filters allow for the attenuation of switching harmonic content, but their resonance can compromise the stability of the system. One of the most common control techniques in these systems consists of a single-loop voltage control with proportional-resonant (PR) or resonant (R) controllers. Numerous previous publications have shown that these systems are only stable for certain ratios between the resonant frequency of the filter ($f_{n}$) and the sampling frequency ($f_{s}$), leading to the proposal of different methods to widen this stability region. However, existing methods are based on a continuous-time domain stability analysis, where some approximations are used. This article, after presenting a discrete-time domain stability analysis without approximations that results in a stability region different from that presented in previous publications, demonstrates that the single-loop voltage control with PR controller and capacitor voltage unitary decoupling allows working with positive proportional gains when $f_{n}$ is either above or below $f_{s}/3$, improving the performance of existing methods. The article also demonstrates that unitary decoupling of the capacitor voltage is not as effective with an R controller. Experimental tests confirm the theoretical analysis conducted.
10 September 2025 in IEEE Transactions on Power Electronics
Voltage-controlled voltage-source inverters with an output $LC$ filter are used in a wide variety of power supply applications. Common control structures include single-loop and double-loop voltage control, typically employing a proportional-resonant voltage controller. This article focuses on the double-loop voltage control, where a proportional controller is employed in the inner current control loop. The stability region is defined as the frequency ratios between the sampling frequency ($f_{s}$) and the natural frequency of the $LC$ filter ($f_{n}$) with which the system can be stable. In previous publications, it has been proposed to place the current controller in the feedback path of the inner control loop, rather than in the forward path, with the aim of increasing the stability region. This article demonstrates that both control structures are equivalent, with the same stability region, although they require different controller tuning. This article presents, for the first time, the complete stability region of the double-loop voltage control, and demonstrates that it can be stable for any frequency ratio $f_{n}/f_{s}$. The stability region presented in previous publications, where $f_{n}=f_{s}/6$ is a critical frequency, is the stability region that allows obtaining a minimum-phase system, which should not be confused with the complete stability region. Finally, it is demonstrated that the unitary decoupling of the capacitor voltage allows obtaining a minimum-phase system across the complete stability region. Experimental results confirm the theoretical analysis conducted.
The control of 400 Hz Ground Power Units (GPUs) in the range of several hundreds of kW poses distinct challenges, as the switching frequency () must be constrained to limit switching losses. This constraint typically results in low ratios of the switching and LC filter natural frequencies () relative to the fundamental frequency. Notably, without mitigation, such systems often face stability issues or non-minimum phase behavior when (where is the sampling frequency). To address these challenges, this paper introduces a single-loop voltage control strategy for a 400 Hz voltage-source inverter (VSI) featuring a robust voltage decoupling scheme. Crucially, this decoupling allows the system to maintain minimum phase characteristics and operate with positive gains even when , effectively solving the stability problems inherent to this operating region. The proposed architecture employs a proportional-resonant (PR) controller, with parameters systematically tuned to achieve maximum system damping based on stability regions dependent on the ratio between the sampling and natural frequencies. Validated through simulation and experimental procedures, the proposed method demonstrates precise voltage tracking and a robust dynamic response, proving its suitability for high-power, high-fundamental-frequency applications.