Tomasz Klimczak

Dr. Tomasz Klimczak

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2019 in Eksploatacja i Niezawodność – Maintenance and Reliability
Verified
Journal Article
Closed access
Jacek PaśJacek Paś
Jacek Paś
TKTomasz Klimczak
Tomasz Klimczak
The article discusses an analysis of the operational and reliability issues, which regards selected fire alarm systems (FAS) exhibiting different functional structures. These systems are operated in a vast transport area, within a specific environment. We can distinguish three basic structures of these systems – focused, dispersed and mixed. A given system functional structure, utilized within a facility (a given area) is a function depending on the configuration, internal connections of elements and devices, and a developed fire scenario. The application of a given system structure for fire protection also depends on the legislation determining the approval of a facility (area) for use. The process of executing a scenario in the event of a fire is ensured by an algorithm implemented in the alarm central unit and other elements of the system. The implementation of all the system requirements specified within a given procedure algorithm depends on, e.g., an appropriate reliability structure and environmental conditions. The article analyses the operational process of selected FAS, which are operated within a vast transport area. It discusses the actual results of the operational process tests, e.g., repair and damage durations. Next, operational relationship graph, taking into account the conducted operational test, was developed. This enabled the determination of relationships that allow to specify the operating and reliability parameters in terms of a FAS staying in the states distinguished for the research. The FAS test methodology presented in the article, owing to meeting specific performance requirements, can be used in the course of developing a fire scenario and designing systems, taking into account various available technical solutions.

18 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
MSMarek Stawowy
Marek Stawowy
Adam RosińskiAdam Rosiński
Adam Rosiński
Jacek PaśJacek Paś
Jacek Paś
TKTomasz Klimczak
Tomasz Klimczak
The article presents issues related to the determination of the continuity quality of power supply (CQoPS) for hospital electrical devices. The model describing CQoPS takes into account power redundancy. The uncertainty modeling method based on the certainty factor (CF) of the hypothesis was used to establish the single-valued CQoPS factor. CQoPS modeling takes into account multidimensional quality models and physical stages of power. The quality models take into account seven dimensions that make up CQoPS (availability, appropriate amount, power supply reliability, power quality, assurance, responsiveness, security). The model of power stages includes five of these stages (power generation, delivery to recipient, distribution by recipient, delivery to device, power-consuming device). To date, when designing hospital power systems, the applied reliability indicators revealed limitations because they do not consider all the possible factors influencing the power continuity. Estimating the supply continuity quality with the use of the uncertainty modeling proposed in this article allows for taking into account all possible factors (not just reliability factors) that may affect supply continuity. The presented modeling offers an additional advantage, namely, it allows an expanded evaluation of the hospital supply system and a description using only one indicator. This fact renders the evaluation of the supply system possible for unqualified staff. At the end of the article, some examples of calculations and simulations are presented, thus showing that the applied methods give the expected results.

15 August 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Jacek PaśJacek Paś
Jacek Paś
Adam RosińskiAdam Rosiński
Adam Rosiński
PWPatryk Wetoszka
Patryk Wetoszka
KBKamil Białek
Kamil Białek
TKTomasz Klimczak
Tomasz Klimczak
MSMirosław Siergiejczyk
Mirosław Siergiejczyk
The article presents a method for assessing the impact of radiated electromagnetic interference generated by a selected rail traction unit on the operational process of trackside video monitoring systems (VMS). VMSs operated throughout an extensive railway area are responsible for the safety of people and property transport processes. Emissions of radiated electromagnetic interference generated in an unintended manner by traction vehicles within a railway line lead to interference in the VMS operating process. Based on the knowledge of actual VMS operating process data, spectral characteristics and values of individual components of disturbing signals occurring in the emissions of radiated electromagnetic interference, it is possible to determine the parameters of damage intensities for the devices and elements of this system. Using that data enables determining the VMS reliability parameters within its operating system, for an extensive railway area. The article’s authors first discussed the basic issues associated with VMS, followed by analysing the topic’s current status. They also presented issues related to measuring interference radiated within a rail area, developed a selected operational process model, and determined selected operational indicators for the structures in question. The paper ends with conclusions.

10 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
TKTomasz Klimczak
Tomasz Klimczak
Jacek PaśJacek Paś
Jacek Paś
Stanisław DuerStanisław Duer
Stanisław Duer
Adam RosińskiAdam Rosiński
Adam Rosiński
PWPatryk Wetoszka
Patryk Wetoszka
MMMichał Mazur
Michał Mazur
The article reviews issues associated with the use of electronic fire alarm systems (FAS). They are operated in various environments and buildings with varying volumes. FAS have to function properly under different operating conditions associated with their operation, as well as power supply and information inflow. Due to their functions, i.e., ensuring the safety of people, vehicles, logistics bases, airports, etc., FAS have to exhibit an appropriately organized reliability structure associated with their implementation and power supply. Operational studies involving FAS operated in various facilities were conducted to this end. The authors determined damage and recovery time intensities. FAS reliability indicators were also determined. The article presents graphs associated with developing the energy balance for selected FAS. The graphs are consistent with the latest and applicable legal regulations. The next stage of the work related to this article was developing an FAS operation process model and conducting computer simulations in order to determine reliability indicators. Such an approach to the FAS operation process enables a rational selection of technical and organizational solutions aimed at guaranteeing reliability in the course of executing operational tasks associated with ensuring fire safety. FAS operational analysis, developing balance graphs and models, as well as the computer simulation, enabled inferring conclusions that might be useful to the process of engineering and operating such systems.

26 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Michał WiśniosMichał Wiśnios
Michał Wiśnios
STSebastian Tatko
Sebastian Tatko
MMMichał Mazur
Michał Mazur
Jacek PaśJacek Paś
Jacek Paś
Jarosław Mateusz ŁUKASIAKJarosław Mateusz ŁUKASIAK
Jarosław Mateusz ŁUKASIAK
TKTomasz Klimczak
Tomasz Klimczak
The article reviews issues associated with the operation of stationary and non-stationary electronic fire alarm systems (FASs). These systems are employed for the fire protection of selected buildings (stationary) or to monitor vast areas, e.g., forests, airports, logistics hubs, etc. (non-stationary). An FAS is operated under various environmental conditions, indoor and outdoor, favourable or unfavourable to the operation process. Therefore, an FAS has to exhibit a reliable structure in terms of power supply and operation. To this end, the paper discusses a representative FAS monitoring a facility and presents basic tactical and technical assumptions for a non-stationary system. The authors reviewed fire detection methods in terms of fire characteristic values (FCVs) impacting detector sensors. Another part of the article focuses on false alarm causes. Assumptions behind the use of unmanned aerial vehicles (UAVs) with visible-range cameras (e.g., Aviotec) and thermal imaging were presented for non-stationary FASs. The FAS operation process model was defined and a computer simulation related to its operation was conducted. Analysing the FAS operation process in the form of models and graphs, and the conducted computer simulation enabled conclusions to be drawn. They may be applied for the design, ongoing maintenance and operation of an FAS. As part of the paper, the authors conducted a reliability analysis of a selected FAS based on the original performance tests of an actual system in operation. They formulated basic technical and tactical requirements applicable to stationary and mobile FASs detecting the so-called vast fires.