Jarosław Mateusz ŁUKASIAK

Mr. Jarosław Mateusz ŁUKASIAK

Military University of Technology in Warsaw, Warsaw, Mazowieckie, Poland
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
Jarosław Mateusz ŁUKASIAKJarosław Mateusz ŁUKASIAK
Jarosław Mateusz ŁUKASIAK
Adam RosińskiAdam Rosiński
Adam Rosiński
Michał WiśniosMichał Wiśnios
Michał Wiśnios
This research paper discusses issues regarding the impact of temperature on the tripping thresholds of intrusion detection system detection circuits. The objective of conducted studies was the verification of a hypothesis assuming that the variability of an intrusion detection system’s (considered as a whole) operating environment temperature can impact the electrical parameters of its detection circuits significantly enough so that it enables a change in the interpretation of the state observed within a given circuit fragment from the state of “no circuit violation” to “circuit violation”. The research covered an intrusion detection system placed in a climatic chamber with adjusted temperature (−25.1 ÷ +60.0 [°C]). The analysis of the obtained results enabled determining the relationships that allow selecting detection circuit resistor values. It is important since it increases the safety level of protected facilities through proper resistor selection, thus, correct interpretation of a detection circuit state.

26 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Michał WiśniosMichał Wiśnios
Michał Wiśnios
STSebastian Tatko
Sebastian Tatko
MMMichał Mazur
Michał Mazur
Jacek PaśJacek Paś
Jacek Paś
Jarosław Mateusz ŁUKASIAKJarosław Mateusz ŁUKASIAK
Jarosław Mateusz ŁUKASIAK
TKTomasz Klimczak
Tomasz Klimczak
The article reviews issues associated with the operation of stationary and non-stationary electronic fire alarm systems (FASs). These systems are employed for the fire protection of selected buildings (stationary) or to monitor vast areas, e.g., forests, airports, logistics hubs, etc. (non-stationary). An FAS is operated under various environmental conditions, indoor and outdoor, favourable or unfavourable to the operation process. Therefore, an FAS has to exhibit a reliable structure in terms of power supply and operation. To this end, the paper discusses a representative FAS monitoring a facility and presents basic tactical and technical assumptions for a non-stationary system. The authors reviewed fire detection methods in terms of fire characteristic values (FCVs) impacting detector sensors. Another part of the article focuses on false alarm causes. Assumptions behind the use of unmanned aerial vehicles (UAVs) with visible-range cameras (e.g., Aviotec) and thermal imaging were presented for non-stationary FASs. The FAS operation process model was defined and a computer simulation related to its operation was conducted. Analysing the FAS operation process in the form of models and graphs, and the conducted computer simulation enabled conclusions to be drawn. They may be applied for the design, ongoing maintenance and operation of an FAS. As part of the paper, the authors conducted a reliability analysis of a selected FAS based on the original performance tests of an actual system in operation. They formulated basic technical and tactical requirements applicable to stationary and mobile FASs detecting the so-called vast fires.

14 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
Jarosław Mateusz ŁUKASIAKJarosław Mateusz ŁUKASIAK
Jarosław Mateusz ŁUKASIAK
Michał WiśniosMichał Wiśnios
Michał Wiśnios
Adam RosińskiAdam Rosiński
Adam Rosiński
Miniature fuses as an anti-damage subsystem perform the important function of protecting electronic devices and systems against permanent damage that may result in electric shocks, fire risks, etc. Their role becomes particularly important when they are installed in such special systems as electronic security systems (ESS). For this reason, there is a need for practical verification of their protective properties. The article presents the results of destructive tests of the circuit-breaking time of miniature fuse-links considered in terms of their usefulness in the ESS with the use of a passive experimental add-on, developed at the Military University of Technology in Warsaw. The characteristics of the measuring attachment circuit and the measurement methodology used were presented. Based on the obtained measurement points of the obtained time–current characteristics, an attempt was made to develop their mathematical model using numerical methods in the field of non-linear regression, using the least squares optimization method (Levenberg–Marquardt algorithm). An exemplary classification of miniature fuse-links has been proposed due to their protective properties of circuits in the context of their use in electronic security systems. The considerations were summarized with an economic analysis of the tested fuse links. The conclusions include proposals for changes to the provisions of the European standard PN-EN 50131-1:2009 “Alarm systems: Intrusion and hold-up systems Part 1: System requirements” and Polish Defence Standard NO-04-A004-8 2016 “Military facilities. Alarm systems. Part 8: Operation”.



30 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
Jarosław Mateusz ŁUKASIAKJarosław Mateusz ŁUKASIAK
Jarosław Mateusz ŁUKASIAK
Adam RosińskiAdam Rosiński
Adam Rosiński
Michał WiśniosMichał Wiśnios
Michał Wiśnios
The objective of this article was to determine, in practice, whether the break time tw of safety fuses can impact the security level provided by electronic security systems (ESSs) that utilize the aforementioned elements as their components. This was the purpose of the conducted destructive testing aimed at estimating the break times for a certain random number of glass tube, miniature 5 × 20 (mm) fuse links with rapid operating characteristics, without a quenching medium and with a rated overcurrent intensity of 0.5 (A) by the selected manufacturers. For this purpose, a dedicated measuring attachment that enables forcing the flow of overcurrents with selected intensities in the range of 1.5 ÷ 11.5 (A) through the studied fuse links has been developed. The obtained results showed that the ratio of the break times between the best and the worst products in the entire tested range of overcurrents ranges from 5.41 (for 3.5 (A)) to 7.80 (at an overcurrent of 9.5 (A)). Statistical analysis of the measurement uncertainties proved that the obtained results of the break time do not depend on the applied research methodology or measuring equipment but are almost exclusively the result of the manufacturing spread of the tested components. Interestingly, the economic analysis did not bring clear conclusions. In this case, the products with the worst break time tw turned out to be almost three times cheaper than the best fuse-links. What is more, the collective packaging of the product that turned out to be the best was cheaper than the next one in the list by almost USD 2.00.