Jonathan M. M. Rubin

Dr. Jonathan M. M. Rubin


Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
JRJonathan M. Rubin
Jonathan M. Rubin
HXHua Xie
Hua Xie
KKKang Kim
Kang Kim
WWWilliam F. Weitzel
William F. Weitzel
SEStanislav Emelianov
Stanislav Emelianov
MOMatthew O'DOnnell
Matthew O'DOnnell
Objective. The purpose of this study was to assess the ability of sonographic elasticity imaging to distinguish acute from chronic deep venous thrombosis (DVT). Methods. Fifty‐four patients, 26 with acute DVT and 28 with chronic DVT, were studied, and we analyzed the data in 46 patients, 23 with acute (mean age, 5.7 days) and 23 with chronic (>8 months) DVT. Scanning was performed with a 5‐MHz linear array transducer during continuous freehand external deformation of each thrombus using the ultrasound scan head. The strains in the thrombi were normalized to the average strain between the skin surface and the back wall of the vein. Relative thrombus echogenicity was measured by comparing the echogenicity of the thrombus with that of the adjacent arterial lumen. Statistical analyses were performed with the Mann‐Whitney U test and receiver operating characteristic analysis. Results. The median normalized strain magnitude for the acute cases was 2.75, with an interquartile range of 2.4 to 3.71, whereas the median normalized strain magnitude for the chronic cases was 0.94, with interquartile range of 0.48 to 1.36. The difference was highly significant (P < 10−7). The area under the receiver operating characteristic curve (Az) was 0.97 ± 0.02 (SE). The echogenicity difference between the populations was highly significant (P < 10−5), with Az of 0.92 ± 0.04. The difference between the Az values was not significant (P > .05). Conclusions. In this population, sonographic elasticity imaging performs at least as well as thrombus echogenicity. Thrombus aging using elasticity imaging would be particularly helpful in evaluating symptoms in patients with post‐thrombotic syndrome.

1 October 2005 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
HXHua Xie
Hua Xie
KKKang Kim
Kang Kim
Salavat AglyamovSalavat Aglyamov
Salavat Aglyamov
SEStanislav Emelianov
Stanislav Emelianov
MOMatthew O’donnell
Matthew O’donnell
JRJonathan M. Rubin
Jonathan M. Rubin

1 May 2003 in Journal of Ultrasound in Medicine
Verified
Journal Article
Closed access
PDF file
JRJonathan M. Rubin
Jonathan M. Rubin
SASalavat R. Aglyamov
Salavat R. Aglyamov
TWThomas W. Wakefield
Thomas W. Wakefield
MOMatthew O'Donnell
Matthew O'Donnell
SEStanislav Emelianov
Stanislav Emelianov

1 January 2008 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
RBRebecca C. Booi
Rebecca C. Booi
PCPaul L. Carson
Paul L. Carson
MOMatthew O’dOnnell
Matthew O’dOnnell
MRMarilyn A. Roubidoux
Marilyn A. Roubidoux
AHAnne L. Hall
Anne L. Hall
JRJonathan M. Rubin
Jonathan M. Rubin

1 November 2019 in Radiology
Verified
Journal Article
Closed access
AWAlec W. Welsh
Alec W. Welsh
JFJ. Brian Fowlkes
J. Brian Fowlkes
SPStephen Z. Pinter
Stephen Z. Pinter
KIKimberly A. Ives
Kimberly A. Ives
GOGabe E. Owens
Gabe E. Owens
GSGordon Stevenson
Gordon Stevenson
With use of three-dimensional power Doppler US, fractional moving blood volume was accurate and reproducible for determining renal perfusion in a porcine model. Background Three-dimensional (3D) fractional moving blood volume (FMBV) derived from 3D power Doppler US has been proposed for noninvasive approximation of perfusion. However, 3D FMBV has never bee...

1 November 1999 in Radiology
Verified
Journal Article
Closed access
JRJonathan M. Rubin
Jonathan M. Rubin
JFJ. Brian Fowlkes
J. Brian Fowlkes
TTTheresa A. Tuthill
Theresa A. Tuthill
AMAaron P. Moskalik
Aaron P. Moskalik
RRRichard T. Rhee
Richard T. Rhee
PCPaul L. Carson
Paul L. Carson
PURPOSE: To use speckle decorrelation in the presence of ultrasonographic (US) contrast agent as an alternative flow measurement technique to Doppler US. MATERIALS AND METHODS: In vivo and in vitro studies were performed. A tube with flowing saline solution containing contrast agent was positioned horizontally across a US image. The amount of decorrelation between a series of images was recorded. The flow profile across the tube was generated by averaging the decorrelation values and was compared with a Doppler frequency shift image. In addition, B-mode images of six rabbit kidneys were obtained during and after intravenous injection of contrast agent. Images were analyzed to compute the correlation between successive points in time. RESULTS: The velocity profiles across the tube were parabolic, with the fastest flow rates measured in the center of the tube. In the rabbit kidneys, measurements indicated the largest decorrelation rates occurred in the larger vessels. The cortical decorrelation rates were s...