Suspended two-dimensional (2D) materials in high-performance devices exhibit unique properties that are critically important for nanoscale mechanical and electromechanical applications, while their frictional laws remain poorly understood. Here, we investigate the nanoscale frictional behavior of suspended WS2 flakes under varying applied loads and scanning rates using atomic force microscopy (AFM), and successfully employ the Bowden–Tabor theory and the thermally activated Prandtl–Tomlinson (PTT) model to analyze the load- and scanning-rate-dependent friction characteristics of suspended 2D systems. The results show that suspended WS2 exhibits higher friction than supported WS2, whereas its friction increases more slowly with applied load, which can be well described by the Bowden–Tabor theory. Moreover, the friction exhibits a logarithmic dependence on scanning rate for both suspended and supported WS2. Quantitative analysis within the framework of the PTT model demonstrates that this model can be successfully extended to describe the rate-dependent friction of suspended WS2, providing a unified framework for both supported interfaces and suspended 2D systems. This work provides valuable guidance for understanding frictional dissipation mechanisms relevant to the design and optimization of WS2-based devices.
Addressing the challenges of electromagnetic compatibility testing and non-destructive inspection of internal structures in miniaturized electronic devices. This paper reports a non-destructive testing method based on wide-field imaging using diamond nitrogen-vacancy (NV) centers, and systematically demonstrates its application on a black-epoxy-encapsulated Universal Serial Bus (USB) flash drive. In the experiment, a swept microwave signal from 2.82 GHz to 2.97 GHz was sequentially injected into the four external interface pins of the USB drive. A bulk diamond served as the quantum sensing layer, and optically detected magnetic resonance (ODMR) was employed to perform wide-field imaging of the microwave field distribution on the surface of the signal lines within a 1 × 1 mm2 region of interest. The experimental results show that the microwave field distributions corresponding to different interface channels are significantly different. Based on these differences, the connection relationship between each signal line and its corresponding interface pin can be clearly identified, and the differences in field distribution as well as crosstalk characteristics among channels can be revealed. The method established in this work provides an effective technical pathway for non-destructive electromagnetic testing and functional verification of electronic products.
To address complex noise in nitrogen-vacancy center fluorescence signal acquisition, a hybrid denoising framework combining marine predators algorithm-optimized variational mode decomposition (VMD) and wavelet thresholding is proposed. MPA adaptively selects VMD parameters, enhancing decomposition reliability. Wavelet thresholding then suppresses noise-dominant intrinsic mode functions while preserving signal components. Results show significant SNR improvement to 57.12 dB (14.6% higher than standalone VMD), RMSE reduction by 56.7%, and 7.9% SNR enhancement over wavelet thresholding alone, with the correlation coefficient reaching 0.97. More importantly, the proposed method substantially improves the accuracy of ODMR resonance parameter estimation. Compared to wavelet denoising, RMSE of the center frequency is reduced by 29.8% and RMSE of the FWHM is reduced by 44.5%; compared to VMD denoising, the FWHM RMSE is reduced by 20.7% while maintaining comparable center frequency accuracy. This approach validates the synergistic effect of VMD’s global decomposition and wavelet’s local denoising, offering an effective method for high-precision ODMR inversion with substantial application potential in quantum sensing and precision measurement.
Weak magnetic video recording with warm atomic ensembles constitutes a non-cryogenic and non-contact methodology for the magnetic source identification and failure reproduction. However, the spatial resolution, imaging speed, and shooting mode from traditional optical-pumping systems have constrained the real recording for ever-changing magnetic phenomena. This work reports a 684-pixel Bell-Bloom atomic magnetic-videorecorder with the global shutter and two-dimensional differential readout, for the real recording of changing gradient fields, which implements the free Larmor precession of Cs atoms to infer local magnetic information, employs a high-speed dual-quadrant Complementary Metal Oxide Semiconductor (CMOS) sensor with the global shutter and the extra microlens focusing to simultaneously detect differential optical rotations on all pixels. Also, a digital micro-mirror device (DMD) is employed to weigh the pixel crosstalk and the spatial resolution, and to facilitate the one-to-one pairing of the profiles for each differential probe beam pair projected onto the two CMOS quadrants. Furthermore, the average sensitivity is demonstrated to be 194 pT/Hz^0.5@0.5-178 Hz, with a high spatial resolution of 137 μm × 137 μm and a frame rate of 205 fps in a field of view up to 5 mm × 2.6 mm. Finally, the magnetic distributions from a moving source have been experimentally measured and found to be in good agreement with the simulation results.
Diamond nitrogen-vacancy (NV) centers are regarded as promising microwave sensors owing to their excellent magnetic sensitivity, stability, and environmental compatibility. However, traditional confocal test platforms based on diamond NV centers are bulky, which limits their practical applications. In this paper, a fiber-coupled compact NV microwave magnetometer is designed that employs the continuous heterodyne measurement method and a fast Fourier transform to measure multiple microwave fields. We integrated the laser excitation module, microwave antenna module, and fluorescence collection module into a single unit, reducing the volume of the magnetometer to 13 cubic centimeters. By adjusting the frequency and power of the measured microwave signals, the applicability of the device under different frequency and power conditions was verified. Experimental tests show that the microwave magnetometer can simultaneously detect multiple microwave fields with different frequencies and power levels, achieving a frequency resolution on the order of millihertz (mHz) and a microwave detection sensitivity of 0.385 nT/Hz1/2. These results demonstrate the magnetometer’s multi-microwave-field measurement capability, making it highly promising for applications such as microwave anomaly localization and medical diagnosis.
2 July 2026 in Japanese Journal of Applied Physics
Near-field scanning microwave microscopy (NSMM) has a significant application in the field of semiconductor electronics and two-dimensional materials characterization. Here, this study proposes a two-port vector network measurement method based on the tip-sample model, which is based on the tip-coupling effect, and acquires the microwave S12 parameters by point-by-point scanning to realize the characterization of the spatial microwave field. Under the input power of 10 dBm and sub-micron tip-sample spacing, the method significantly improves the field contrast between the defect region and the surrounding region. In this study, high-resolution detection of the surface defect field distributions with dimensions of 4.7 μm × 2.7 μm and 4.9 μm × 3.7 μm was successfully achieved. The results indicate that the attenuation of the microwave signal caused by the defect regions was 0.49 nW and 0.54 nW, respectively. This method provides a reference nondestructive testing solution for device structures in microelectromechanical systems.