Alexander Buzin

Dr. Alexander Buzin

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2002 in Polymer
Verified
Journal Article
Closed access
ABAlexander Buzin
Alexander Buzin
MPM. Pyda
M. Pyda
PCP. Costanzo
P. Costanzo
KMK. Matyjaszewski
K. Matyjaszewski
BWB. Wunderlich
B. Wunderlich

1 August 2002 in Thermochimica Acta
Verified
Journal Article
Closed access
EKE.V Konyukhova
E.V Konyukhova
ABAlexander Buzin
Alexander Buzin
YGYu.K Godovsky
Yu.K Godovsky

1 December 1998 in Langmuir
Verified
Journal Article
Closed access
SSSergei S. Sheiko
Sergei S. Sheiko
ABAlexander Buzin
Alexander Buzin
Aziz MuzafarovAziz Muzafarov
Aziz Muzafarov
EREvgenij A. Rebrov
Evgenij A. Rebrov
EGElena V. Getmanova
Elena V. Getmanova

1 December 2021 in European Polymer Journal
Verified
Journal Article
Closed access
TKTimofey I. Kolesnikov
Timofey I. Kolesnikov
AOAlexandra M. Orlova
Alexandra M. Orlova
ATAnna Y. Tsegelskaya
Anna Y. Tsegelskaya
GCGeorgij V. Cherkaev
Georgij V. Cherkaev
AKAlexander S. Kechekyan
Alexander S. Kechekyan
AKAlexander A. Kuznetsov
Alexander A. Kuznetsov

1 March 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
Ilya D. KlabukovIlya D. Klabukov
Ilya D. Klabukov
TTTimur Tenchurin
Timur Tenchurin
ASAlexey Shepelev
Alexey Shepelev
DBDenis Baranovskii
Denis Baranovskii
VMVissarion Mamagulashvili
Vissarion Mamagulashvili
SCSergei N. Chvalun
Sergei N. Chvalun
This article reports the electrospinning technique for the manufacturing of multilayered scaffolds for bile duct tissue engineering based on an inner layer of polycaprolactone (PCL) and an outer layer either of a copolymer of D,L-lactide and glycolide (PLGA) or a copolymer of L-lactide and ε-caprolactone (PLCL). A study of the degradation properties of separate polymers showed that flat PCL samples exhibited the highest resistance to hydrolysis in comparison with PLGA and PLCL. Irrespective of the liquid-phase nature, no significant mass loss of PCL samples was found in 140 days of incubation. The PLCL- and PLGA-based flat samples were more prone to hydrolysis within the same period of time, which was confirmed by the increased loss of mass and a significant reduction of weight-average molecular mass. The study of the mechanical properties of developed multi-layered tubular scaffolds revealed that their strength in the longitudinal and transverse directions was comparable with the values measured for a decellularized bile duct. The strength of three-layered scaffolds declined significantly because of the active degradation of the outer layer made of PLGA. The strength of scaffolds with the PLCL outer layer deteriorated much less with time, both in the axial (p-value = 0.0016) and radial (p-value = 0.0022) directions. A novel method for assessment of the physiological relevance of synthetic scaffolds was developed and named the phase space approach for assessment of physiological relevance. Two-dimensional phase space (elongation modulus and tensile strength) was used for the assessment and visualization of the physiological relevance of scaffolds for bile duct bioengineering. In conclusion, the design of scaffolds for the creation of physiologically relevant tissue-engineered bile ducts should be based not only on biodegradation properties but also on the biomechanical time-related behavior of various compositions of polymers and copolymers.

1 July 2020 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
VDVarvara A. Demina
Varvara A. Demina
SKSergei V. Krasheninnikov
Sergei V. Krasheninnikov
ABAlexander Buzin
Alexander Buzin
RKRoman A. Kamyshinsky
Roman A. Kamyshinsky
NSNatalya V. Sadovskaya
Natalya V. Sadovskaya
SCSergei N. Chvalun
Sergei N. Chvalun