Yuxin Xie

Mr. Yuxin Xie


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2025 in Processes
Verified
Journal Article
Open access
PDF file
QHQian Huang
Qian Huang
JXJiangtao Xiao
Jiangtao Xiao
RLRui Liao
Rui Liao
YXYuxin Xie
Yuxin Xie
XLXueyuan Long
Xueyuan Long
CZCheng Zeng
Cheng Zeng
In gas transmission stations, flame arrestors are typically installed in pipelines and venting systems to prevent the flames resulting from accidental ignition or deflagration of combustible gases during transmission from propagating through the pipelines. During actual operation, the presence of solid particulates in the gas compromises the flame-arresting efficacy and increases the failure rate of current pipeline flame arrestors. This study employs an integrated approach combining theoretical analysis and numerical simulation to establish a numerical model for flame arrestors that accounts for solid particle deposition effects. The model reveals the distribution characteristics of velocity fields, pressure fields, gas phase volumetric concentration fields, and solid deposition rate fields within pipeline flame arrestors. It systematically investigates the influence mechanisms of porosity, flame arrestor core thickness, inlet flame velocity, arrestor length, particle size, particle concentration on pressure drop, flame arrestment velocity, and deposition rate. These findings provide theoretical support for optimizing flame arrestor structural design and reducing operational failure rates.

8 October 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
诚曾诚 曾
诚 曾
XLXueyuan Long
Xueyuan Long
QHQian Huang
Qian Huang
HHHuirong Huang
Huirong Huang
YTYuan Tian
Yuan Tian
CTChengcai Tang
Chengcai Tang
Mechanically lined pipes (MLP) combine a carbon-steel base pipe with a thin corrosion-resistant liner that transfers load through frictional contact. This numerical study compares the stress responses of matched monometallic and mechanically lined pipes under prescribed internal pressure, temperature, and bending. Three-dimensional finite element models are used to represent the material layers, contact, friction, and thermal loading. Circumferential mesh refinement and comparison with field inspection data provide checks on the reported stress response. In the non-bending one-factor cases, pressure and diameter primarily affect equivalent stress, whereas increasing temperature increases liner compression and base-pipe equivalent stress. At constant total wall thickness, increasing liner thickness reduces liner compression but increases stress in the thinner base pipe. Bending increases both response measures. Local sensitivity and two-factor analyses characterize stress variations within the sampled conditions. Exploratory regression equations show high internal cross-validation accuracy, and on 22 finite-element cases, the unchanged regression equations achieved R2 values of 0.965 for liner stress and 0.986 for base-pipe stress. These results support stress-trend estimation within the tested conditions but do not establish accuracy for arbitrary five-factor combinations or a universal failure threshold.

17 March 2026 in Materials
Verified
Journal Article
Open access
PDF file
QHQian Huang
Qian Huang
ZSZhe Shen
Zhe Shen
YXYuxin Xie
Yuxin Xie
LMLingyan Mu
Lingyan Mu
XLXueyuan Long
Xueyuan Long
RWRuiLin Wang
RuiLin Wang
In this study, a combined approach of molecular dynamics (MD) simulations and experimental bottle tests was employed to systematically investigate the demulsification performance and underlying mechanisms of two distinct demulsifiers—Demulsifier X (SP/BP series and alcohol-initiated polyethers) and Demulsifier Y (AP/AE series and amine-initiated polyethers)—targeting polymer-containing oil-in-water (O/W) emulsions derived from heavy oil polymer flooding. Molecular models for heavy oil, saline water, partially hydrolyzed polyacrylamide (HPAM), and demulsifiers were constructed using BIOVIA Materials Studio software. Their dynamic behaviors at the oil–water interface were simulated within three distinct saline systems containing NaCl, CaCl2, and MgCl2, respectively. Simulation results indicated that the demulsifiers effectively displaced interfacial HPAM molecules, increased interfacial tension, and reduced interfacial interaction energy. Experimental bottle tests, evaluating the effects of settling time, temperature, and concentration on dehydration rates and oil content, confirmed that Demulsifier Y outperformed Demulsifier X. Specifically, Demulsifier Y achieved superior dehydration rates with lower dosages, shorter settling times, and reduced temperature requirements under optimal conditions. This work provides both microscopic mechanistic insights and macroscopic experimental validation for the screening and application of high-efficiency demulsifiers.