30 September 2022 in IEEE Transactions on Instrumentation and Measurement
This study presents a novel capacitive sensor and a new technique for splicing multiple sensor segments to extend measurement ranges. Single segments adopting a Vernier structure were used for absolute measurements with a range of 600 mm. Two independent groups of induction electrodes, with fixed distances between two groups, were included to smooth the transition of signals near the joint and eliminate splicing errors introduced by installation and manufacturing flaws. The passive design of the mover simultaneously reduced limitations caused by increased cable length, achieved using several groups of emission electrodes (EEs) and reception electrodes (REs). The corresponding induction signal provided both displacement measurements and position determinations. A single-segment prototype of the proposed sensor was manufactured using a PCB process, in which each segment achieved an absolute-type measurement accuracy of ± $3 ~\mu \text{m}$ . A series of experiments were used to validate the proposed technique, applied to two-segment rulers. Results revealed that the measurement precision, peak value of repeatability, and 3-sigma value were ± $3 ~\mu \text{m}$ , less than $0.6 ~\mu \text{m}$ , and approximately $1.62 ~\mu \text{m}$ , respectively, over a measurement range expanded to 1140 mm after splicing. Thus, absolute-type displacement measurements are viable over the entire range.
18 March 2025 in IEEE Sensors Journal
This study presents a high-precision, long-range absolute time-grating linear displacement sensor based on a multilayer cascade structure. In the layer I structure, electric field coupling between the fixed and moving rulers generates an induction signal on the moving ruler. In the layer II structure, the transmitting stage receives this signal via internal wiring, and signal cascading is achieved through secondary coupling between the transmitting and receiving stages. The cascade structure makes full use of the available space above the fixed ruler, eliminating the need to expand the sensing areas of the fixed and moving rulers. This structure enhances signal strength through multilayer coupling and avoids the need for moving part leads. The sensor’s electrode array enables long-range measurements, with absolute positioning determined by a simple subtraction between two single-row incremental time-grating sensor signals phases, bypassing complex coding and decoding. Experimental analysis reveals traveling wave crosstalk, causing nonlinear measurement errors. Time-division multiplexing completely suppresses crosstalk and enhances measurement accuracy. After optimization, the sensor’s peak-to-peak measurement error is reduced by approximately three times, achieving an accuracy of ±0.2 μm over a 400 mm range after compensation.
20 March 2026 in Sensors and Actuators A: Physical
9 September 2025 in IEEE Sensors Journal
Multidimensional angular displacement detection technology is essential for enabling the high-precision control of advanced spherical motors and ball hinges. However, existing conventional methods based on optical or electromagnetic principles are limited in their capacity for obtaining measurements in real time or in the ability to combine high accuracy with a large measurement range. This paper addresses these issues by proposing a novel spherical two-degree-of-freedom (2-DOF) angular displacement sensor that employs two distinct spherical electrode array configurations as the stator and rotor, respectively. The electrodes on the stator and rotor are separated by a short radial distance and represent capacitors with a capacitance that varies according to the area of overlap between the electrodes. Four two-phase orthogonal sinusoidal excitation signals of identical frequency and amplitude are applied along the two spatially orthogonal rotational angles (α and β) of the stator electrode array, respectively. As a result, each electrode in the rotor electrode array captures induced sinusoidal signals of identical frequency, whose phase characteristics are directly correlated with the rotational angles of the rotor in both the α and β directions. The induced signals from each rotor electrode are processed using a spatial phase combination method, which yields separate measurement signals Uoα, containing only angular displacement information for the α direction, and Uoβ, containing only angular displacement information for the angle β direction. Finally, the angular displacements of the rotor along the α and β directions are determined independently by extracting the phases from Uoα and Uoβ, respectively. Accuracy measurements on an experimental platform demonstrate that the calibrated sensor obtains a peak-to-peak error of 0.012° in the α and β directions over an entire ±20° measurement range in each direction.
28 January 2026 in IEEE Transactions on Instrumentation and Measurement
The combined measurement of linear and angular displacements using a single two-dimensional (2D) sensor is of considerable interest in robotics, precision machining, and related fields. However, existing 2D sensors are subject to numerous sources of error and limited measurement ranges that greatly restrict their use in these fields. Moreover, relatively few studies have analyzed these error sources and established posture error models for optimizing sensor designs. The present work addresses these issues by proposing a novel cylindrical capacitive 2D sensor composed of a stator subject to linear displacements in the x direction and a rotor subject to rotational displacements about the x axis. First, a mathematical model of sensor measurements is derived, and a corresponding mathematical model of posture error is constructed to analyze the influence of deviations between the stator and rotor on the measurement accuracy. Second, the posture error model is applied to optimize the sensor design by arranging four sets of induction electrodes in offset configurations along the linear and rotational directions, and thereby suppressing both periodic and long-range measurement errors. Furthermore, the validity of the proposed modifications is demonstrated based on the results of numerical electric field calculations. Finally, the obtained results are verified experimentally based on systematic analyses of the measurement performances observed for a prototype sensor. The prototype sensor achieves a linear displacement measurement accuracy of 17.3 μm within a 0–100 mm range and an angular displacement accuracy of 58.3″ over a 0–360° range. Accordingly, the posture error model reported herein provides critical guidance for the design, structural optimization, and error compensation of cylindrical capacitive 2D sensors.