Daniel Dolan

Daniel Dolan

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in Journal of Structural Engineering
Verified
Journal Article
Closed access
TATugce Akbas
Tugce Akbas
RSRichard Sause
Richard Sause
JRJames M. Ricles
James M. Ricles
RGRyan Ganey
Ryan Ganey
JBJeffrey Berman
Jeffrey Berman
HBHans-Erik Blomgren
Hans-Erik Blomgren
A cross-laminated timber (CLT) panel is a heavy timber structural component fabricated by laminating layers of timber boards in an orthogonal pattern. This paper presents a study of the lateral-load response of self-centering (SC) posttensioned CLT structural walls (i.e., SC-CLT walls), which are constructed by posttensioning CLT wall panels to the foundation with vertical posttensioning steel bars. The bars pass through the CLT panels and are anchored to the CLT panels at the top of the wall and to the foundation at the bottom of the wall. Cyclic loading tests were conducted on a series of SC-CLT wall specimens with different configurations. Structural limit states of SC-CLT walls under lateral load are identified. Two types of analytical models are proposed to predict SC-CLT wall response, namely, a design-oriented analytical model based on simple mathematical expressions, and a fiber-element-based numerical model. Comparisons between the analytical and experimental results are made, which indicate that the simple mathematical expressions and the fiber-element-based numerical model provide accurate estimates of the lateral-load response of SC-CLT walls under cyclic loading.

1 August 2009 in Journal of Structural Engineering
Verified
Journal Article
Closed access
JXJian Xu
Jian Xu
DDDaniel Dolan
Daniel Dolan
Testing showed that the hysteretic behavior of nailed wood joints governs the response of many wood systems when subjected to lateral loadings. Unfortunately, commercially available software does not have the appropriate hysteretic element for a nailed wood joint, and the accuracy and versatility of the previously developed nail joint elements are not satisfactory. A general hysteretic model, Bouc-Wen-Barer-Wen, was modified to represent the hysteretic behavior of a nailed joint, in which the hysteretic constitutive law is characterized by a series of ordinary differential equations. It can produce versatile and smoothly varying hysteresis curves, is nonlinear, history dependent, and includes stiffness and strength degradation, and pinching. Based on the test data, the suitable parameters for different joint configurations can be estimated through genetic algorithms. This model was embedded in commercially available software, ABAQUS/Standard (Version 6.5), as a user-defined element which accounted for the...

1 December 2024 in Journal of Structural Engineering
Verified
Journal Article
Closed access
SPShiling Pei
Shiling Pei
KRKeri L. Ryan
Keri L. Ryan
JBJeffrey W. Berman
Jeffrey W. Berman
JLJohn W. van de Lindt
John W. van de Lindt
SPSteve Pryor
Steve Pryor
DDDaniel Dolan
Daniel Dolan

1 August 2009 in Journal of Structural Engineering
Verified
Journal Article
Closed access
JXJian Xu
Jian Xu
DDDaniel Dolan
Daniel Dolan
After modifications, the Bouc-Wen-Barber-Wen (BWBN) model was used in simulating the hysteretic behavior of wood light-frame shear walls. A complete shear wall model is composed of boundary framing members and two-diagonal modified BWBN hysteretic springs. The parameters of the springs can be estimated based on the shear wall test data or detailed shear wall simulation results. To verify the accuracy and efficiency of this shear wall model, a two-story residential building was simulated and a three-dimensional dynamic analysis was conducted on it. The resultant structural responses agreed with the test results well.

20 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
MMMostafa Mohammadabadi
Mostafa Mohammadabadi
Vikram YadamaVikram Yadama
Vikram Yadama
DDDaniel Dolan
Daniel Dolan
During this study, full-size wood composite sandwich panels, 1.2 m by 2.4 m (4 ft by 8 ft), with a biaxial corrugated core were evaluated as a building construction material. Considering the applications of this new building material, including roof, floor, and wall paneling, sandwich panels with one and two corrugated core(s) were fabricated and experimentally evaluated. Since primary loads applied on these sandwich panels during their service life are live load, snow load, wind, and gravity loads, their bending and compression behavior were investigated. To improve the thermal characteristics, the cavities within the sandwich panels created by the corrugated geometry of the core were filled with a closed-cell foam. The R-values of the sandwich panels were measured to evaluate their energy performance. Comparison of the weight indicated that fabrication of a corrugated panel needs 74% less strands and, as a result, less resin compared to a strand-based composite panel, such as oriented strand board (OSB), of the same size and same density. Bending results revealed that one-layer core sandwich panels with floor applications under a 4.79 kPa (100 psf) bending load are able to meet the smallest deflection limit of L/360 when the span length (L) is 137.16 cm (54 in) or less. The ultimate capacity of two-layered core sandwich panels as a wall member was 94% and 158% higher than the traditional walls with studs under bending and axial compressive loads, respectively. Two-layered core sandwich panels also showed a higher ultimate capacity compared to structural insulated panels (SIP), at 470% and 235% more in bending and axial compression, respectively. Furthermore, normalized R-values, the thermal resistance, of these sandwich panels, even with the presence of thermal bridging due to the core geometry, was about 114% and 109% higher than plywood and oriented strand board, respectively.

1 December 2021 in Journal of Structural Engineering
Verified
Journal Article
Open access
PDF file
JFJace Furley
Jace Furley
JLJohn W. van de Lindt
John W. van de Lindt
SPShiling Pei
Shiling Pei
SWSarah Wichman
Sarah Wichman
HHHamed Hasani
Hamed Hasani
EMEric McDonnell
Eric McDonnell
This paper presents a new stochastic methodology for evaluating and quantifying the downtime of a structure in terms of a family of fragilities that represent the probability of exceeding prescribed times to return to functionality. This methodology integrates several existing concepts, namely, Federal Emergency Management Agency P-58 and Resilience-based Earthquake Design Initiative (REDi), to build a family of system (building) level fragility curves corresponding to the time needed to achieve different recovery levels (reoccupancy, functional recovery, and full recovery). This approach enables one to propagate uncertainty throughout the procedure so that variations in the delay time and repair schedules are accounted for in the resulting fragilities. As an illustrative example of this approach, the methodology is applied to assess the downtime of a two-story mass timber building that was originally tested at the [email protected] outdoor shake table in 2017. One unique aspect of this analysis is that it incorporates a relatively new material, cross-laminated timber (CLT), in a resilient posttension rocking wall design application. Nonstructural components representing a typical office building were selected and incorporated into the procedure for the two-story CLT rocking wall building. Time-to-functionality fragility curves are then developed for the two-story building, and potential design and resilience-focused applications are discussed.