Mona Ahmed Abdelrahman

Dr. Mona Ahmed Abdelrahman


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2024 in Sustainable Chemistry and Pharmacy
Verified
Journal Article
Closed access
SSShymaa S Soliman
Shymaa S Soliman
MAMona Ahmed Abdelrahman
Mona Ahmed Abdelrahman

30 October 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
SAShimaa A. Atty
Shimaa A. Atty
SAShereen M. Azab
Shereen M. Azab
AIAsmaa H. Ibrahim
Asmaa H. Ibrahim
FFFatma A. Fouad
Fatma A. Fouad
MTMahmoud A. Tantawy
Mahmoud A. Tantawy
MAMona Ahmed Abdelrahman
Mona Ahmed Abdelrahman
This work reports a novel, ultra-sensitive electroanalytical sensor based on a carbon paste electrode modified with multi-walled carbon nanotubes, cesium chloride, and sodium dodecyl sulfate (CPE/MWCNT-CsCl/SDS) for the determination of the antihistamine levocabastine (LC). The structural, morphological, and surface properties of the nanocomposite and modified electrode were thoroughly characterized. Cyclic voltammetry (CV) and square wave voltammetry (SWV) showed that combining MWCNTs and CsCl markedly enhanced the peak current by providing a porous, high-surface-area network, while the addition of SDS enabled remarkable preconcentration via electrostatic interactions and conferred antifouling properties. The oxidation of LC was an irreversible, predominantly diffusion-controlled process with a one-electron, one-proton rate-determining step. Under optimized conditions, the sensor exhibited a wide linear dynamic range (4.0 nM–22 µM in buffer) with a limit of detection of 0.9 nM in artificial tear fluid, and was successfully applied to a commercial nasal spray, with recoveries of 99.15–100.80% (RSD ≤ 1.12%). As a result, we were able to detect LC either alone or in the presence of azelastine HCl (AZE) or emedastine difumarate (EMD) using square wave voltammetry. The AGREE metric gave a score of 0.79, indicating the greenness of the overall analytical procedure. The sensor is suitable for routine quality control and ocular pharmacokinetic studies.

24 December 2025 in BMC Chemistry
Verified
Journal Article
Open access
PDF file
SSShymaa S Soliman
Shymaa S Soliman
MAMona Ahmed Abdelrahman
Mona Ahmed Abdelrahman
Background: Reliable chemometric models require representative and well-distributed calibration and validation datasets. Objective: The current study introduces a novel framework integrating diverse sampling strategies with multivariate modeling for the simultaneous UV–Vis quantification of aztreonam (AZM) and meropenem (MPM). Methods: Three sampling techniques, including Monte Carlo (MC), Latin Hypercube Sampling (LHS), and Sobol Sequences (SS), were systematically evaluated in combination with Partial Least Squares (PLS), Genetic Algorithm–Assisted PLS (GA-PLS), and Artificial Neural Networks (ANN). Response surface strategy was followed for each sampling technique to assess their space coverage and points’ distribution across the experimental domain. Moreover, a hybrid variable-selection approach, namely, Genetic Algorithm Information Complexity–Partial Least Squares (GA-ICOMP-PLS), was also introduced to optimize PLS model variables. Different validation techniques, including nested cross-validation, Y-randomization tests, and noise-profiling, have been followed to ensure the models’ reliability. Results: The ANN model trained with the SS technique achieved the highest predictive accuracy, reducing RMSE by 2.6% for AZM and 39.9% for MPM compared to standard PLS. However, LHS-GA-PLS delivered low prediction errors (22.8% AZM and 5.7% MPM), while MC-PLS showed lower consistency due to non-uniform sampling. GA-ICOMP-PLS further improved prediction performance for both analytes, with error reduction ranging from 35.1% to 63.6% compared to conventional PLS. Rigorous validation testing confirmed unbiased predictions and model resilience under realistic analytical conditions. Significance: This is the first study to integrate structured sampling with chemometric modeling for β-lactam analysis. The approach improved model robustness, generalization, and sustainability, achieving high green metrics of SDS (Safety Data Sheets), AGREE (Analytical Greenness metric), and BAGI (Balanced Analytical Greenness Index) values of 0.84 and 85.0, respectively. The developed method represents a reliable, efficient, and eco-friendly strategy for pharmaceutical quality control and environmental monitoring. Graphical

20 October 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
MAMona Ahmed Abdelrahman
Mona Ahmed Abdelrahman
AMAya A. Mouhamed
Aya A. Mouhamed
OHOla Gamal Hussein
Ola Gamal Hussein
MTMahmoud A. Tantawy
Mahmoud A. Tantawy
SASuliman A. Almahmoud
Suliman A. Almahmoud
EMEman M. Moaaz
Eman M. Moaaz
Accurate monitoring of antidepressant drugs is essential for ensuring therapeutic efficacy and minimizing adverse effects, creating a demand for sensitive and reliable analytical methodologies. In the present study, a novel electrochemical sensor was developed for the determination of dothiepin hydrochloride (DOTH) using an iron-based metal–organic framework supported on nitrogen-doped graphite (Fe-MOF@N-dG). The composite material was synthesized through a rapid sonication-assisted approach at ambient temperature, avoiding hydrothermal/solvothermal heating and reducing the consumption of hazardous organic solvents. The physicochemical and electrochemical characteristics of the prepared Fe-MOF@N-dG were investigated using scanning electron microscopy, energy-dispersive X-ray spectroscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, and electrochemical impedance spectroscopy. Characterization results confirmed the successful formation of the composite and demonstrated a synergistic interaction between the Fe-MOF and nitrogen-doped graphite. The conductive N-dG network facilitated electron transfer, while the Fe-MOF provided abundant electrocatalytic active sites, which enhanced sensing performance. Electrochemical measurements were performed in Britton–Robinson buffer solution at pH 3.0 under optimized conditions. The fabricated sensor exhibited a linear response over the concentration range of 0.6–100 μM, with a detection limit of 0.073 μM, indicating good sensitivity toward DOTH determination. The proposed method was validated with respect to accuracy and precision and successfully applied to the analysis of spiked human plasma samples. The environmental sustainability of the developed methodology was also assessed using the recently introduced Environmental, Performance, and Practicality Index (EPPI), together with other established green analytical evaluation tools. The findings demonstrate that the Fe-MOF@N-dG platform offers a potentially sensitive, reliable, and environmentally sustainable strategy for electrochemical determination of DOTH in human plasma.

30 April 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
MAMona Ahmed Abdelrahman
Mona Ahmed Abdelrahman
HAHazim M Ali
Hazim M Ali
Mohammed GamalMohammed Gamal
Mohammed Gamal
LELobna Mohammed Abd Elhalim
Lobna Mohammed Abd Elhalim
MEMai Mohamed Abd El-Aziz
Mai Mohamed Abd El-Aziz
RTRehab Moussa Tony
Rehab Moussa Tony
Multivariate calibration methods have proven to be helpful in interpreting complex spectral data, particularly in the simultaneous analysis of pharmaceutical mixtures. In this study, three chemometric-assisted spectrophotometric methods were developed and validated for the simultaneous assessment of flunixin meglumine (FM) and florfenicol (FF), namely, multivariate curve resolution–alternating least squares (MCR-ALS), artificial neural networks (ANNs), and partial least squares (PLS). These methods were successfully utilized to address the significant spectral overlap between FM and FF in their combined dose form, enabling simultaneous quantification without prior chromatographic separation. Statistical analysis was conducted to compare the performance of the proposed methods to that of a published HPLC method, and the results showed no significant variation in trueness or precision. The proposed methods were validated according to ICH guidelines, showing high sensitivity, low LOD and LOQ, and excellent precision (%RSD < 2.0%). Furthermore, they were evaluated for environmental sustainability using the analytical greenness (AGREE) metric and the complex modified green analytical procedure index (Complex MoGAPI), which provided a greenness score of 0.7 and a total sustainability score of 80. These results demonstrate the applicability of the proposed chemometric methods as straightforward, effective, and ecologically beneficial substitutes for regular quality control analysis.