The ITER Thermal Shields (TS) consist of actively cooled stainless steel panels. Their role is to minimise the radiation heat load from warm components, such as the Vacuum Vessel (VV) and the cryostat, hence contributing to insulating the magnet system operating at 4.5 K. The panels, cooled by 304L stainless steel pipes stitch welded to 10 mm to 20 mm thick 304LN plates, were coated by a low emissivity silver layer following welding of the pipes and bending operations. Pressurised He gas flows in the pipes at a temperature of 80 K and a pressure of 1.8 MPa at the inlet. These components have been manufactured and delivered to IO and their assembly had been started. Three leaks were detected in Helium leak tests during site acceptance test of the TS. A failure analysis was carried out based on advanced non-destructive and destructive examination techniques, including X-ray microtomography and Focused Ion Beam - Scanning Electron Microscopy (FIB-SEM), confirming crack initiations of different severities, in particular presence of multi-branched “lightning bolt” transgranular cracks through the thickness of the pipes and of corrosion residues featuring high chlorine content. The root cause of the leakages has been univocally associated to Stress Corrosion Cracking (SCC), initiated by halide residues from the silver coating process in combination with the stress induced by the attachment, by welding, of the pipes to the plates. The paper summarises the results of these investigations and the lessons learned, the remedial actions implemented and the planned repair/replacement solutions.
12 January 2024 in IEEE Transactions on Applied Superconductivity
The High Luminosity Large Hadron Collider (HL-LHC) is a major upgrade to the existing Large Hadron Collider (LHC) at CERN, aimed at increasing the integrated luminosity of the collider by a factor of ten [1]. A key component of the HL-LHC are the superconducting Nb3Sn quadrupole magnets, known as MQXF, whose purpose is to focus the particle beam [3]. In order to ensure the proper operation and structural reliability of the MQXF quadrupoles, it is essential to qualify the welds of their cold mass, used as a He container of the magnets. This paper describes the process of qualification of the welds involved in the closure of the cold mass, including the testing and inspection methods used to evaluate their strength and soundness. The results of the qualification process are used to ensure that the MQXF quadrupoles cold masses can withstand the high-stress operating conditions of the HL-LHC and operate as expected at cryogenic temperature. The qualification process has been used to implement a novel approach for quality control of the production parts using Phased Array Ultrasonic Testing (PAUT). This advanced testing method uses phased array ultrasonic probes to scan the welds and generate a detail 3D image of their internal structure. This allows for a more accurate and efficient inspection of the welds, compared to traditional ultrasonic testing methods. Overall, the welding qualification process for the cold mass of the MQXF quadrupoles is a crucial step in ensuring the safe and reliable operation of the HL-LHC.
This manuscript reports on the application of copper thermal spraying in the manufacturing process of an electrical connection between Nb3Sn cables for superconducting magnets of fusion reactors. The joint is realized through diffusion bonding of the sprayed coating of the two cables. The main requirement for such a connection is its electrical resistance, which must be below 1 nΩ at B = 8 T, I = 63.3 kA and T = 4.5 K. Micrographs of the joint prototype were taken to relate the joint resistance with its microstructure and to provide feedback on the manufacturing process. Optical microscopy (OM) was used to evaluate the grain size of the coating, presence of oxide phases and to analyze the jointed surfaces. Scanning electron microscopy (SEM) and, in particular, energy-dispersive X-ray spectroscopy (EDX) were used to confirm the elemental composition of specimens extracted from the prototype. It is shown that the copper coating has an oxide concentration of 40%. Despite this, the resistance of the prototype is 0.48 nΩ in operating conditions, as the oxides are in globular form. The contact ratio between the jointed surfaces is about 95%. In addition, residual resistivity ratio (RRR) measurements were carried out to quantify the electrical quality of the Cu coating.
The mechanical characterization of austenitic stainless steels at cryogenic temperatures is crucial for the structural components of superconducting magnets in fusion devices and particle accelerators. This study presents and compares mechanical testing results for FXM-19 (Nitronic 50) and 316LNH (316LN with nitrogen in the upper limit) while comparing their behaviour against crack propagation, with emphasis placed on a novel analytical procedure for characterizing unstable crack propagation (UCP) during fracture toughness (FT) testing at 4 K. FXM-19 demonstrated excellent yield strength, making it one of the most desirable alloys for use as structural materials in high magnetic fields at cryogenic temperatures (superconductor base projects). It also exhibited UCP behaviour, which is very complex to characterize at very low temperatures due to the existence of discontinuous plastic flow or serrated yielding in this kind of materials. A new methodology was developed to distinguish between unstable crack tearing and serrations at 4 K. The study reveals that FXM-19 consistently exhibits unstable crack propagation after stable tearing, whereas 316LNH maintains stable crack propagation with exceptional toughness. These findings have critical implications for material selection in safety-critical cryogenic applications, where stable and predictable fracture behaviour is often preferred.