Porous asphalt has excellent permeability and larger air voids. Due to the low stability strength of asphalt binder with aggregates, Malaysia uses porous asphalt roads for lightweight vehicle road transportation. Numerous studies indicate utilizing Recycled High-Density Polyethylene in porous asphalt road surface. As a result, it was utilised as an additional binder material to enhance the asphalt binder. The main purpose of this study is to investigate the stability of modified porous asphalt samples and evaluate the optimum percentage of HDPE plastic waste from 3%, 6% and 9%. The aggregates, asphalt properties, Marshall Parameters and waster absorption test are in comply with JKR Standard and PWD 2008. At 3% of plastic addition has improved the stability of porous asphalt specimens. Adding plastic waste as a binder helps strengthen asphalt binding.
Bamboo Ash is a safer and more sustainable building material. It is possible to use bamboo ash as a partial cement replacement as an alternative to cement application and also to reduce pollution. For this study, the main purpose is to determine the compressive strength and water absorption of cement sand brick containing bamboo ash. Laboratory tests such as compression tests and water absorption tests on cement sand brick with bamboo ash as a partial replacement for cement have been conducted. The mixes with various ratios using bamboo ash are 5%, 7%, and 10%. The specimen size for cement sand brick is 215 mm long, 102.5 mm wide, and 65 mm deep according to BS3921:1985. The results from the specimens containing Bamboo Ash have been compared to the control specimens. The water absorption test results increase as the percentage of Bamboo Ash increases due to particle size and air void, but the compressive strength decreases at 28 days.
10 March 2025 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
The rising threat of heat-related and fire incidents underscores the urgent need for advanced thermal and fire detection systems to ensure timely and accurate responses. This report presents a smart fire detection project utilizing the YOLOv5 deep learning model. The project aims to design an early fire detection system with real-time capabilities. The proposed system implements a convolutional neural network (CNN) and the YOLOv5 real-time object identification system, enhancing fire detection through anchor box optimization. In the incident of a fire, the system sends an alert to the user’s Telegram app bot via the Internet of Things (IoT), assisting in taking necessary precautions. The project demonstrates notable efficiency in fire detection and alerting capabilities, with system evaluation metrics showing an F1 score of 95%, mAP@50 of 97%, accuracy 96.3%, and a recall rate of 89%. These results underscore the system's reliability and precision. The project contributes significantly to Sustainable Development Goals (SDG), goal 9 for industry, innovation, and infrastructure, and 11 for sustainable cities and communities highlighting its potential to enhance fire safety measures in various settings.
Anchor bolts have been used to attach the steel structure of concrete and transfer load into the concrete. Anchor bolts in concrete are to withstand the shear force as they connect steel beams to the reinforced concrete foundations. The research was carried out to increase the understanding and investigating the performance of anchor bolts Pigtail since there is a lack of research on the bolt and to compare it with anchor bolts J which have been widely used by the industry. According to the methodology, testing the tensile load was used in this research to get a maximum load capacity of the anchor bolt in concrete. The sample was embedded in concrete cylinders of 75mm radius and 300mm height. Depths of embedment were 200mm, 230mm, and 260mm. The Universal Testing Machine, UTM was used to test the strength of tensile. 12 samples were used, each type and depth used two samples to get the average value using concrete grade 30. The samples underwent the process of curing for 28 days. The anchor bolts J used a 40mm bending radius and the length of hook was 100mm. Anchor bolts pigtail also used the 10 bending radius with depth of 8mm that have been compressed using 16mm radius rigs with a load of 500kN. Results of the research showed the depth of 260mm for Pigtail almost the same with J 60.529kN and 53.628kN and anchor bolts J were 75.557kN and 76.332kN. Difference of the values was not too far vary when compared with the 200mm and 230mm depths. Each comparison showed the ability of each bolt and anchor bolt failure occurred. Performance of the anchor bolts pigtail can be used on a structure or a higher load at an embedment of 260mm. Embedment of 200mm and 230mm can be used on a lighter load if steel material saving is a priority in every usage.
31 March 2024 in Journal of Advanced Research in Applied Mechanics
Due to the country's expanding population and the resulting growth of the building industry, brick is one of the most crucial materials used in construction projects in Malaysia. Producing large amounts of bricks requires a lot of cement yet this method has environmental consequences due to increasing carbon emissions into the atmosphere. Therefore, this study aims to use partial Sago Fine Waste (SFW) to replace the cement. About 60 tonnes of sago trash are dumped into the closest river every day during the production of sago starch. To protect the environment and contributing to sustainable development, this study has been conducted on the production of bricks from waste materials. For this study, the brick specimens were prepared using 0%, 1%, 3%, 5%, 7% and 9% of SFW with a water-cement ratio of 0.6 fixed at 1:3 sand cement ratio. The total specimens that were produced for testing are 72 bricks. The water curing for concrete has been conducted at 7 and 28 days. The overall results revealed that both density and compressive strength are decreases as the percentages of SFW increases. The initial rate of absorption increases due to the increasing percentage of SFW. However, all the results obtained are still met the requirements. Based on the findings, the optimum percentage SFW are SFW1W0.6 with strength 5.18 MPa. The optimum brick properties of SFW1W0.6 is normal weight with density 2092.86 kg/m3 and lowest initial rate absorption with 0.91 kg/m3.min.