Graham Hugh Isaac

Prof. Graham Hugh Isaac

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2022 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
GPGregory M Pryce
Gregory M Pryce
BSBismaya Sabu
Bismaya Sabu
MAMazen Al-Hajjar
Mazen Al-Hajjar
RWRuth K Wilcox
Ruth K Wilcox
JTJonathan Thompson
Jonathan Thompson
SWSophie Williams
Sophie Williams
Total Hip Arthroplasty (THA) is one of the most common and successful surgical interventions. The survivorship at 10 years for the most commonly used systems is over 95%. However, the incidence of revision is usually much higher in the 0–1 year time period following the intervention. The most common reason for revision in this early time period is dislocation and subluxation, which may be defined as complete or permanent, and partial or temporary loss of contact between the bearing surfaces respectively. This study comprises the development of a geometric model of bone and an in situ total hip replacement, to predict the occurrence and location of bone and component impingement for a wide range of acetabular cup positions and for a series of frequently practiced activities of daily living. The model developed predicts that anterior-superior component impingement is associated with activities that result in posterior dislocation. The incidence may be reduced by increased cup anteversion and inclination. Posterior-inferior component impingement is associated with anterior dislocation activities. Its incidence may be reduced by decreased cup anteversion and inclination. A component impingement-free range was identified, running from when the cup was positioned with 45° inclination and 25° anteversion to 70° inclination and 15°–20° anteversion.

16 September 2021 in Progress in Biomedical Engineering
Verified
Journal Article
Open access
OVOliver Vickers Vickers
Oliver Vickers Vickers
PCPete Culmer
Pete Culmer
GIGraham Hugh Isaac
Graham Hugh Isaac
RKRobert William Kay
Robert William Kay
MSMatthew Peter Shuttleworth
Matthew Peter Shuttleworth
SWSophie Williams
Sophie Williams
Surgery to implant a total hip replacement (THR) is very successful in reducing pain and restoring function. This procedure has become more prevalent, and projections estimate further increases in demand. However, complications can arise, and current diagnostic techniques often fail to expose underlying issues before they result in a catastrophic failure that requires revision surgery. An instrumented implant, with embedded sensors capable of real time condition monitoring, would be an attractive proposition to incorporate within a THR. Continued advances in the performance and miniaturisation of electronic components, embedded systems, sensing and wireless communications have given the tools and resources medical device manufacturers need to innovate in the field of implantable medical devices. Smart implants are already being widely used in healthcare including pacemakers, cochlear implants, glucose monitors and insulin pumps however, a widely used smart THR has not yet been realised. Since the implantation of the first instrumented hip implant in the 1960s there have been several in vitro studies monitoring levels of implant loosening. Additionally, significant research has been conducted using instrumented THRs to perform in vivo measurement of biomechanical metrics, including force and moments. To date less than 100 patients have successfully received an instrumented implant. The results of these studies have aided researchers, designers and surgeons in wider research projects, however, the motivation behind the work was to provide discrete biomechanical data sets and not provide real-time condition monitoring of an implants performance or highlight early indications for revision surgery. If in vivo sensing within a THR is to be achieved and adopted in regular clinical practice then the following challenges need to be addressed: choice of the sensing method, biocompatibility and integration within the implant, power supply, communication, and regulatory considerations.

27 May 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
MSMackenzie Smeeton
Mackenzie Smeeton
SWSimon P. Williams
Simon P. Williams
JAJames Anderson
James Anderson
RWRuth K Wilcox
Ruth K Wilcox
TBTim N Board
Tim N Board
GIGraham Hugh Isaac
Graham Hugh Isaac
Background/Objectives: The stability of dual mobility (DM) total hip arthroplasty (THA) is often attributed to reduced impingement incidence and a superior range of motion (ROM) compared to the corresponding values when standard implants are used. However, few studies have directly explored this. Thus, the purpose of the present study was to compare the incidence of impingement and the range of motion between standard and DM acetabular cups, whose diameters are suited to the same patient anatomy. Methods: One standard and two DM implants were virtually implanted into a pelvis using a previously developed geometric model. Joint motions, which were representative of seven dislocation-prone activities of daily living (ADLs), as well as walking, were applied to each device type at a range of cup orientations (inclination/anteversion). Conclusions: There were no placement positions that avoided impingement across all seven ADLs, regardless of cup construct type. A similar impingement incidence and ROM were observed for standard and DM constructs, although the consequences of impingement are potentially more serious for DM devices (metal–metal contact) than for standard constructs (metal–polyethylene contact). This finding contradicts the common notion that DM-THAs have a reduced impingement incidence and superior ROM, instead suggesting that their stability may be attributed to alternative mechanisms, such as increased jump distance.

12 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MSMatthew Peter Shuttleworth
Matthew Peter Shuttleworth
OVOliver Vickers Vickers
Oliver Vickers Vickers
MSMackenzie Smeeton
Mackenzie Smeeton
TBTim N Board
Tim N Board
GIGraham Hugh Isaac
Graham Hugh Isaac
RKRobert William Kay
Robert William Kay
Dual mobility (DM) implants are being increasingly used for total hip arthroplasties due to the additional range of motion and joint stability they afford over more traditional implant types. Currently, there are no reported methods for monitoring their motions under realistic operating conditions while in vitro and, therefore, it is challenging to predict how they will function under clinically relevant conditions and what failure modes may exist. This study reports the development, calibration, and validation of a novel inertial tracking system that directly mounts to the mobile liner of DM implants. The tracker was custom built and based on a miniaturized, off-the-shelf inertial measurement unit (IMU) and employed a gradient-decent sensor fusion algorithm for amalgamating nine degree-of-freedom IMU readings into three-axis orientation estimates. Additionally, a novel approach to magnetic interference mitigation using a fixed solenoid and magnetic field simulation was evaluated. The system produced orientation measurements to within 1.0° of the true value under ideal conditions and 3.9° with a negligible drift while in vitro, submerged in lubricant, and without a line of sight.

29 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
OVOliver Vickers Vickers
Oliver Vickers Vickers
PCPete Culmer
Pete Culmer
GIGraham Hugh Isaac
Graham Hugh Isaac
RKRobert William Kay
Robert William Kay
MSMatthew Peter Shuttleworth
Matthew Peter Shuttleworth
SWSophie Williams
Sophie Williams
An instrumented total hip replacement (THR) implant capable of remote and continuous monitoring would be an attractive prospect for a surgeon to conveniently track the recovery of their patients. Measuring the relative motion of the prosthesis components would provide insight into joint kinematics and contribute to the detection of adverse events including impingement and subluxation. The aim of this study was to develop a sensing system to measure the relative orientation and translation of the prosthesis components. A tri-axis magnetometer and a permanent magnet were integrated into clinically available THR components, forming a magnetic position and orientation sensing system. A robotic arm was used to articulate the components through controlled motion routines and record the orientation of the components. The output of the robot arm and a camera tracking system were used to validate the performance of the sensing system. The sensing system measured the relative orientation of the components to two degrees of freedom with an RMSE of <4.0° and measured the displacement of the femoral head during an impingement-driven subluxation motion with an RMSE of 0.2 mm. This proof-of-concept work has shown that magnetic sensing technology can track the position and orientation of THR components. With further development, this sensing method could feature within an instrumented THR implant.

25 July 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
MSMackenzie Smeeton
Mackenzie Smeeton
GIGraham Hugh Isaac
Graham Hugh Isaac
RWRuth K Wilcox
Ruth K Wilcox
JAJames Anderson
James Anderson
TBTim N Board
Tim N Board
SWSophie Williams
Sophie Williams
Despite their emerging use, the in vivo behaviour of dual-mobility (DM) total hip replacements (THRs) is not well understood. Therefore, the purpose of this study was to assess the articulating surfaces of 20 early-retrieved DM polyethylene liners (mean length of implantation 20.0 ± 18.8 months) for damage to improve the current understanding of their in vivo functional mechanisms. The internal and external surfaces of each liner were visually and geometrically assessed, and the material composition of embedded debris particles were further characterized. Scratching and pitting were the most common modes of damage identified on either surface, and a high incidence of burnishing (50%) and embedded debris (65%) were observed on the internal and external surfaces, respectively. Embedded debris particles were commonly titanium- or iron-based, although other materials such as cobalt-chrome and tantalum were also identified. The geometric assessment demonstrated highly variable damage patterns across the liners, with the internal surfaces commonly presenting with crescent-shaped, circumferential, or circular regions of penetration whilst the external surfaces commonly presented with regions of deep pitting or gouging. This study demonstrates that DM-THRs primarily articulate at the head/liner junction, and that polyethylene liners are capable of rotating about the femoral neck axis, although the extent of this may be limited in some cases. Additionally, this study suggests that intra-prosthetic dislocation and edge loading may remain pertinent failure mechanisms of DM implants despite the advent of highly crosslinked polyethylene and design features, thus highlighting the need for enhanced monitoring of these devices.