In this work, a method for the rapid synthesis of metallic microtracks on polyetherimide is presented. The method relies on the photosynthesis of silver nanoparticles on the surface of the polymer substrates from photosensitive silver chloride (AgCl), which is synthesized directly on the polyetherimide surface. The study reveals that the use of AgCl as a photosensitive intermediate accelerates the reactions leading to the formation of silver nanoparticles by up to two orders of magnitude faster than other photodecomposition schemes. The patterning can be conducted under blue light, with notable advantages over UV exposure. Polymers of significant interest to the microelectronics and 3D printing industries can be directly patterned by light using this photography‐inspired technique at throughputs high enough to be commercially advantageous. Light exposures as short as a few seconds are sufficient to allow the direct metallization of the illuminated polyetherimide surface. The results show that the silver required for the seed layer is minimal, and the later copper electroless plating results in the selective growth of conductive tracks for circuitry on the light‐patterned areas, both on flexible films and 3D printed surfaces.
In this research, it is aimed to present a comparative analysis of soft–rigid industrial parallel rigid grippers to compare their technical capabilities and assess the potential for soft–rigid grippers to address the challenge of grasping fragile objects with various shapes and sizes. In this research, 24 soft–rigid grippers are first identified through a scoping review using the Web of Science database, capturing their technical features and performance. Providing a variable stiffness grasp (n = 9, 37.5%) and a limited grasp capability (n = 8, 33.3%) is the most common advantage and challenge, respectively, of soft–rigid grippers. Pneumatic actuators (n = 12, 50.0%), followed by tendon‐driven electric rotary actuators (n = 9, 37.5%), are the predominant actuators used for soft–rigid grippers. Soft–rigid grippers are found to have a lower output force‐to‐weight ratio (n = 9, median , standard deviation (σ) = 15.17) in comparison to industrial parallel rigid grippers (n = 63, , ), but can provide a larger range of motion (n = 20, , ). This is the first quantitative comparative analysis between industrial parallel rigid and soft–rigid grippers, enhancing the understanding of their status and prospects in industrial applications. Herein, a common approach is proposed to standardize reporting to facilitate benchmarking between research‐based and industrial grippers and highlight controlling soft–rigid grippers is an underexplored area that can enhance the technology's performance.
15 February 2019 in IEEE Transactions on Electron Devices
Surgery to implant a total hip replacement (THR) is very successful in reducing pain and restoring function. This procedure has become more prevalent, and projections estimate further increases in demand. However, complications can arise, and current diagnostic techniques often fail to expose underlying issues before they result in a catastrophic failure that requires revision surgery. An instrumented implant, with embedded sensors capable of real time condition monitoring, would be an attractive proposition to incorporate within a THR. Continued advances in the performance and miniaturisation of electronic components, embedded systems, sensing and wireless communications have given the tools and resources medical device manufacturers need to innovate in the field of implantable medical devices. Smart implants are already being widely used in healthcare including pacemakers, cochlear implants, glucose monitors and insulin pumps however, a widely used smart THR has not yet been realised. Since the implantation of the first instrumented hip implant in the 1960s there have been several in vitro studies monitoring levels of implant loosening. Additionally, significant research has been conducted using instrumented THRs to perform in vivo measurement of biomechanical metrics, including force and moments. To date less than 100 patients have successfully received an instrumented implant. The results of these studies have aided researchers, designers and surgeons in wider research projects, however, the motivation behind the work was to provide discrete biomechanical data sets and not provide real-time condition monitoring of an implants performance or highlight early indications for revision surgery. If in vivo sensing within a THR is to be achieved and adopted in regular clinical practice then the following challenges need to be addressed: choice of the sensing method, biocompatibility and integration within the implant, power supply, communication, and regulatory considerations.