Matteo Di Giacomo

Mr. Matteo Di Giacomo

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2026 in IEEE Transactions on Plasma Science
Verified
Journal Article
Open access
MGMatteo Di Giacomo
Matteo Di Giacomo
ACA. Cubi
A. Cubi
NHN. Hajnal
N. Hajnal
BBB. Bienkowska
B. Bienkowska
SAS. Akbas
S. Akbas
MFMarco Fabbri
Marco Fabbri
Accurate Monte Carlo (MC) simulations are essential for predicting system performance, optimizing design, and ensuring reliable operation. One of the aspects of achieving high-fidelity simulations is the level of detail present in the CAD geometry, especially for diagnostics. This study investigates how varying levels of geometric details, ranging from simplified to more detailed models, affect the neutron and photon flux distributions on the JT-60SA tokamak model. In particular, it focuses on the effect of backscattering from surrounding components on diagnostic and actuator systems such as the Thomson scattering system (TSS) and pellet launching system (PLS). After a brief explanation of the simplification procedure, this work highlights an increase of up to 20% in terms of neutron flux in some diagnostic locations due to the implementation of the ex-cryostat components (e.g., common stage) while decreasing at larger distances from the tokamak.

29 September 2026 in Nuclear Fusion
Verified
Journal Article
Open access
AVA. Valentine
A. Valentine
SBS. Bradnam
S. Bradnam
JMJ. Moorehead
J. Moorehead
DLD. Laghi
D. Laghi
ABA. Bittesnich
A. Bittesnich
AHA. Harte
A. Harte
Several international leading efforts are focused on the improvement of evaluations for nuclear data. This data captures all of the physics of nuclear interactions for which the applications are far ranging from medical fields to criticality simulations. Nuclear analysis in the field of fusion, commonly referred to as neutronics, is one such application, typically employing Monte Carlo methods that rely on continuous-energy, pointwise cross-section data. Historically, the most widely adopted and complete radiation transport code in this field is MCNP, however in recent years there has been an evident trend in exploration of alternatives, most notably OpenMC. Nuclear analysis is a critical driver of the design, operation, safety and decommissioning of future fusion power plants stressing the importance of confidence in the transport codes and underlying nuclear data used in prediction of the radiation environment. Here we present recent developments to the JADE tool—a framework originally conceived for verification and validation of nuclear data within MCNP, now extended to performing cross-code comparisons. In particular, the developments required for the complete integration of OpenMC are detailed. A demonstration of this capability is presented for several of the currently implemented computational and experimental OpenMC benchmarks, with results compared against MCNP with the Fusion ENDF-3.2c and Evaluated Nuclear Data Library/B-VIII.0 nuclear data libraries.

1 October 2026 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
PDF file
KMKatarzyna Mikszuta-Michalik
Katarzyna Mikszuta-Michalik
ACAlvaro Cubi
Alvaro Cubi
MFMarco Fabbri
Marco Fabbri
MGMatteo Di Giacomo
Matteo Di Giacomo
This study presents a methodology for assessing neutronics models of JT-60SA by comparing simulated neutron spectra with spectra reconstructed from neutron activation measurements. The analysis was performed using synthetic data generated with the Monte Carlo N-Particle (MCNP) radiation transport code for an existing model, as the final detailed tokamak model remains under development. Rather than limiting the assessment to a direct comparison with activation measurement, the proposed approach incorporate neutron spectrum reconstruction as a complementary method to evaluate agreement between simulated and actual spectra. The analysis demonstrates the feasibility and potential of the methodology rather than reproducing experimental conditions. Several spectrum unfolding techniques were applied: Tikhonov Regularisation, Minimum Fisher Information, Maximum Entropy, and Maximum Likelihood. Results were additionally combined into an average reconstructed spectrum to reduce method-dependent differences. The MCNP-calculated spectrum for the P10 port was used in FISPACT-II, advanced nuclear simulation software, to simulate foil activation. The reconstructed spectra and FISPACT-II activities were compared against reference MCNP data. Irradiation was assumed to last the entire experimental campaign. Longer irradiation time limits the activation foil set and increases reconstruction uncertainty. Results demonstrate that the high-intensity region of the neutron spectrum can be reconstructed with an uncertainty below 25%. Performing reconstructions separately across distinct energy ranges enables accurate determination of dominant high-intensity peaks despite numerical challenges from large intensity gradients. Shorter irradiation time allows the use of additional dosimetry foils, reducing the overall reconstruction uncertainty to approximately 23% for the full spectrum. Individual unfolding methods reproduce different spectral regions with varying accuracy, whereas averaging results reduces the discrepancy between the reconstructed and reference spectra. The study demonstrates the potential of combining established reconstruction methods for complementary assessment of neutronics simulations and identifies the treatment of large spectral intensity gradients as an important area for further methodological development.

11 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
MGMatteo Di Giacomo
Matteo Di Giacomo
MCMarta Campos
Marta Campos
ACAlvaro Cubi
Alvaro Cubi
AKAljaž Kolšek
Aljaž Kolšek
RJRafael Juarez
Rafael Juarez
MFMarco Fabbri
Marco Fabbri
Nuclear energy production requires robust shielding solutions to ensure the safety of personnel and equipment across a wide range of reactor technologies. Shield for Fusion (S4F) is a new development in nuclear analysis models, and codes a computational framework for optimizing radiation shielding design in fusion reactor applications using OpenMC neutronics simulations and genetic algorithms (GAs). The framework addresses four-layer shielding cabinets with six commercially viable materials, exploring 10,000 possible configurations through a template-based approach with density correction factors. The genetic algorithm efficiently converges to optimal solutions in approximately 100 simulations by balancing competing objectives: neutron flux attenuation, dose minimization, material cost, and weight. Compared to uniform sampling, the GA demonstrates superior performance by identifying high-performing parameter regions with improved attenuation and reduced cost. The framework includes an inverse design tool for rapid retrieval of configurations matching target performance criteria requested by external users, currently available for selected neutron source spectra. Results demonstrate effective multi-objective optimization for fusion shielding applications, with the open-source code available for adaptation to different simulation setups.