This study analyses daylight availability in a faculty lecture classroom using illuminance measurements and a survey of students. The results of the measurements conducted in mid-February showed that the recommended horizontal illuminance level (300 lx) was achieved at 50% of the measurement points around midday (12:00 h and 14:00 h), while only 0–15% of the area met this requirement at 8:00 h and 16:00 h. The minimum illuminance level (100 lx) was satisfied at all measurement points around midday but decreased to 25–45% in the early morning and late afternoon. Survey results indicated that 76.7% of students reported the need for artificial lighting during the winter period. Since natural daylight is sufficient during certain periods of the day, optimisation of the lighting system and the integration of controlled sensors for supplementary lighting are recommended.

1 January 2025
Verified
Book Chapter
Open access
Darija GajićDarija Gajić
Darija Gajić
LPLjubiša Preradović
Ljubiša Preradović
SPSlobodan Peulić
Slobodan Peulić
BABiljana Antunović
Biljana Antunović
MPMilan Pupčević
Milan Pupčević
SCSasa Cvoro
Sasa Cvoro

24 August 2026 in Buildings
Verified
Journal Article
Open access
PDF file
MKMilovan Kotur
Milovan Kotur
MPMilan Pupčević
Milan Pupčević
PGPetar Gvero
Petar Gvero
Darija GajićDarija Gajić
Darija Gajić
LPLjubiša Preradović
Ljubiša Preradović
SCSasa Cvoro
Sasa Cvoro
This paper presents an analysis of indoor air quality (IAQ) and occupant perception under different mechanical ventilation operational modes in a university amphitheater. Indoor environmental parameters, including air temperature, relative humidity, indoor air velocity, and CO2 concentration, were measured in accordance with ISO 7726. Ventilation performance and outdoor air supply requirements were evaluated according to BAS EN 16798-1 and ASHRAE 62.1, while thermal comfort interpretation followed ISO 7730. In parallel, a questionnaire survey was conducted to assess occupants’ perceptions of indoor air quality and its influence on concentration under different ventilation operating conditions. The results showed that CO2 concentrations occasionally exceeded 1000 ppm during extended occupancy periods but remained below 800 ppm for more than 60% of the measurement time. According to BAS EN 16798-1, the indoor environment was predominantly classified as Category I based on the indoor–outdoor CO2 concentration difference. Survey responses indicated that most students perceived the indoor air as clean, while 67% reported that IAQ influenced their ability to concentrate. The findings highlight the importance of occupancy-related ventilation control strategies in large educational spaces and demonstrate the potential for balancing indoor air quality and energy efficiency through appropriate ventilation system operation. The presented methodology may support future development of data-driven approaches for optimizing mechanical ventilation performance in university buildings.