Solution‐processed low‐bandgap semiconductors are crucial to next‐generation infrared (IR) detection for various applications, such as autonomous driving, virtual reality, recognitions, and quantum communications. In particular, III–V group colloidal quantum dots (CQDs) are interesting as nontoxic bandgap‐tunable materials and suitable for IR absorbers; however, the device performance is still lower than that of Pb‐based devices. Herein, a universal surface‐passivation method of InAs CQDs enabled by intermediate phase transfer (IPT), a preliminary process that exchanges native ligands with aromatic ligands on the CQD surface is presented. IPT yields highly stable CQD ink. In particular, desirable surface ligands with various reactivities can be obtained by dispersing them in green solvents. Furthermore, CQD near‐infrared (NIR) photodetectors are demonstrated using solution processes. Careful surface ligand control via IPT is revealed that enables the modulation of surface‐mediated photomultiplication, resulting in a notable gain control up to ≈10 with a fast rise/fall response time (≈12/36 ns). Considering the figure of merit (FOM), EQE versus response time (or −3 dB bandwidth), the optimal CQD photodiode yields one of the highest FOMs among all previously reported solution‐processed nontoxic semiconductors comprising organics, perovskites, and CQDs in the NIR wavelength range.
We report on the characteristics of a lab-assembled UV single photon detector based on a thermoelectrically cooled silicon carbide (4H-SiC) avalanche photodiode (APD). The SiC- APD in this experiment was fabricated with a beveled mesa structure, with electronics designed to achieve passive Geiger-mode operation and to convert the avalanche signal to a transistor–transistor logic signal by readout backend. We attached the SiC-APD to a 4-stage thermoelectric cooler to vary APD temperature from 25 °C to −30 °C, and investigated dark count rates according to applied bias voltage at different temperatures. Breakdown voltages applied to the SiC-APD were also measured while adjusting APD temperature. Finally, we evaluated afterpulse characteristics through the time-correlated single-photon counting method, and observed that afterpulsing probability increases with decreasing APD temperature.
26 June 2023 in IEEE Transactions on Instrumentation and Measurement
Single photon sources based on single emitters such as 2D materials and impurities in diamond are of great interest for many application fields including quantum communication, quantum metrology and quantum sensing. In photometry and radiometry, a single photon source, having the ability to emit only one photon in a well-defined time and frequency domain, represents a promising candidate to realize a photon number-based primary standard for quantum radiometry. At the Korea Research Institute of Standards and Science (KRISS), we have realized three kinds of single photon sources based on various single emitters at room temperature: silicon vacancy in diamond, defects in gallium nitride (GaN), and vacancy in hexagonal boron nitride (hBN). We found common factors related with the relaxation times of the internal states that indirectly affect the photon number stability. We observed a high photon number stability in the GaN emitter due to faster relaxation times compared with the hBN emitter, which on the other hand produced high rates of photons per second (> 10 6 ). Moreover, we demonstrate repeatable radiant flux measurements of a bright hBN single photon emitter for a wide radiant flux range from a few tens of femtowatts to one picowatt.
Near‐infrared (NIR) wavelengths offer a powerful approach for non‐invasive physiological monitoring due to the deep tissue penetration and ability to detect various endogenous molecules such as hemoglobin species, water, and lipids. Herein, we demonstrate a high‐speed, non‐contact photoplethysmography (PPG) system based on indium arsenide (InAs) colloidal quantum dots (CQDs). To this end, a seedless injection‐based one‐pot method was devised to synthesize monodisperse NIR InAs CQDs. This scalable approach enables precise bandgap tuning from 1.53 to 1.09 eV, aligning with the absorption spectra of hemoglobin and oxyhemoglobin. Furthermore, the proposed CQD‐based PPG system is integrated into a real‐time acquisition platform. Exercise‐induced desaturation tests show that the CQD‐based PPG system exhibits consistent oxygen saturation rate (SpO 2 ) trends compared to commercial oximeters, exhibiting a considerable agreement of 99.76% (SpO 2 range: 90%–92%). The system also shows reliable operation with a bandwidth up to 2.5 kHz under multi‐lock‐in detection.
We present an automated, software-driven instrument for rapid and precise characterization of after-pulsing probability (PAP) in single-photon avalanche diodes (SPADs). The system replaces subjective manual analysis with a robust algorithm that separates correlated after-pulses from uncorrelated noise in inter-arrival time histograms. Using this instrument, we systematically map PAP as a function of dead time (1–80 μs) and detection efficiency (2.5%–25%) for commercial InGaAs/InP SPADs in free-running and gated modes. For the ID210 detector at 10% efficiency, PAP decreases from 12.8% to 3.2% as dead time increases from 1 to 20 μs. Gated operation further reduces PAP to 0.8%, a fourfold improvement. The instrument achieves measurement repeatability better than 1% and reduces analysis time from hours to minutes. This tool enables data-driven optimization of SPADs for quantum communications, LiDAR, and time-resolved spectroscopy.