Introduction. To attain high efficiency and reliability in the field of clean energy conversion, power electronics play a significant role in a wide range of applications. More effort is being made to increase the dependability of power electronics systems. Purpose. In order to avoid any undesirable effects or disturbances that negatively affect the continuity of service in the field of energy production, this research provides a fault detection technique for insulated-gate bipolar transistor open-circuit faults in a three-level diode-clamped inverter of a wind energy conversion system predicated on a doubly-fed induction generator. The novelty of the suggested work ensures the regulation of power exchanged between the system and the grid without faults, advanced intelligence approaches based on a multilayer artificial neural network are used to discover and locate this type of defect; the database is based on the module and phase angle of three-phase stator currents of induction generators. The proposed methods are designed for the detection of one or two open-circuit faults in the power switches of the side converter of a doubly-fed induction generator in a wind energy conversion system. Methods. In the proposed detection method, only the three-phase stator current module and phase angle are used to identify the faulty switch. The primary goal of this fault diagnosis system is to effectively detect and locate failures in one or even more neutral point clamped inverter switches. Practical value. The performance of the controllers is evaluated under different operating conditions of the power system, and the reliability, feasibility, and effectiveness of the proposed fault detection have been verified under various open-switch fault conditions. The diagnostic approach is also robust to transient conditions posed by changes in load and speed. The proposed diagnostic technique's performance and effectiveness are both proven by simulation in the SimPower /Simulink® MATLAB environment.
Introduction. Microgrids (MGs) have garnered significant attention for their numerous advantages, providing a solution for powering remote and distant locations while enhancing system reliability. In MGs, distributed generation inverters generally operate in parallel with the droop control strategies. This study focuses on the approach based on the P-f/Q-V droop control technique with virtual impedance for AC MG management. Essentially, the virtual impedance loop aims to decouple reactive and active power control without the need for additional physical components. Novelty. This research proposes enhancing voltage control in AC MG systems by introducing new methods of various control strategies, including PI and Fuzzy Logic Controller (FLC), and evaluating the effectiveness of each approach. The mathematical model of a system is always an approximation of real systems, variations or errors between mathematical models and real systems are referred to as uncertainty. This concept of uncertainty is present in both signals and models. In our study, uncertainties may involve factors related to the filter LC components. By employing advanced control strategies like FLC, the purpose of this research aims to contribute to the optimization and reliability of AC MG systems through the improvement of voltage control, which leads to guaranteed equitable power-sharing. Results. The major advantages of the FLC are robustness for any variation on the system and fast response. MATLAB software is used to simulate and validate the suggested control. Practical value. The simulation results show that the suggested control performs better in precise tracking optimization and robustness for all disturbances on the system compared to a PI controller. References 24, table 5, figures 11.
21 October 2023 in Electrical Engineering & Electromechanics
Introduction. Recently, the number of high and medium voltage applications has increased dramatically. The connection between these different applications requires series-parallel combinations of power semiconductors. Multilevel converter topologies provide major advantages to these applications. In this paper, a grid-connected photovoltaic system with a hybrid energy storage system using a five-level neutral point clamped inverter is studied. Although the multilevel inverter has many advantages over the two-level inverter, it has a high probability of experiencing an open circuit fault. In this context, the five-level inverter has 24 controllable switches, one of which may experience an open circuit fault at any time. Therefore, it plays an important part in the reliability and robustness of the whole system. The novelty of this paper presents an approach to accurately detect the open circuit fault in all insulated gate bipolar transistors of a five-level neutral point clamped inverter in a photovoltaic power generation application with a hybrid energy storage system. Purpose. Before using fault-tolerant control to ensure service continuity, fault diagnosis techniques must first be used, which are the crucial phase of reliability. Methods. A detection method based on the maximum and minimum error values is proposed. These errors are calculated using the expected and measured line-to-line pole voltages. Results. The open circuit fault detection method is implemented using MATLAB/Simulink. Simulation results showed the accuracy of detecting the open circuit fault in all insulated gate bipolar transistors in a short time. Moreover, this method is adaptable to several applications and is also robust to transient regimes imposed by solar irradiation and load variations.
Early and reliable diagnosis of inter-turn short-circuit (ITSC) faults is critical to maintaining the reliability, availability, and safe operation of doubly fed induction generators (DFIGs) used in wind energy conversion systems (WECSs). Incipient winding faults are particularly challenging to identify because their electrical signatures can be masked by the inherent spectral complexity of DFIG operation and variations in wind and operating conditions. This study proposes a hybrid Fast Fourier Transform-Adaptive Neuro-Fuzzy Inference System (FFT–ANFIS) diagnostic framework for the detection, localization, and severity assessment of ITSC faults in both stator and rotor windings. The proposed approach employs the FFT method to extract fault-sensitive harmonic components from stator-current signals, which are subsequently used as diagnostic features by an Adaptive Neuro-Fuzzy Inference System (ANFIS). By integrating spectral feature extraction with nonlinear neuro-fuzzy classification, the proposed framework provides an efficient and interpretable mechanism for distinguishing healthy and faulty operating conditions and assessing fault severity. The methodology is evaluated using MATLAB/Simulink simulations under healthy and multiple ITSC fault conditions with different fault locations and severity levels. The results demonstrate 100% classification accuracy for stator faults, rotor faults, and multiple short-circuit (MSC) fault conditions, together with near-zero prediction error in fault-severity estimation. These results confirm the high discriminative capability of the selected FFT-based spectral features and the effectiveness of ANFIS in establishing the nonlinear relationship between fault signatures and fault conditions. In addition, the proposed framework maintains low computational complexity and is therefore suitable for real-time condition-monitoring applications. Compared with existing diagnostic approaches, the proposed method provides a unified framework for multi-fault diagnosis while combining high diagnostic accuracy, computational efficiency, and interpretable decision-making. The proposed FFT–ANFIS framework consequently offers a practical approach for early fault detection and condition-based maintenance of DFIG-based wind turbines, with the potential to reduce unplanned downtime, maintenance requirements, and energy-production losses.