Mushk Bughio

Dr. Mushk Bughio

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Muhammad Shoaib KhanMuhammad Shoaib Khan
Muhammad Shoaib Khan
MKMuhammad Khan
Muhammad Khan
MBMushk Bughio
Mushk Bughio
Bushra Danish TalpurBushra Danish Talpur
Bushra Danish Talpur
IKIn Sup Kim
In Sup Kim
Jongwon SeoJongwon Seo
Jongwon Seo
Heritage buildings are subject to severe damage due to their exposure to dynamics such as environmental changes, earthquakes, structural loads, etc., thus needing a proper maintenance and management system. However, during the restoration, maintenance, and management process, heritage building practitioners face numerous challenges, such as inefficient project management, financial loss, and project delay. These problems arise due to a lack of digital documentation and updated information management systems. Heritage building management still uses traditional management techniques where heritage information is managed using multiple format systems by different professionals, thus missing collaboration, information integration, and interoperability. Building information modeling (BIM) is presented here as a supporting tool to address these issues. The aim of this study is to develop a novel HBIM framework to manage heritage buildings in an integrated and interoperable environment that supports 3D digital documentation to conserve a heritage building and facilitate restoration planning and facility management (FM) activities. Moreover, we demonstrate FM integration with BIM to promote this digital technique. The results indicate that the proposed framework is feasible and effective in providing information integration and communication between stakeholders in managing heritage buildings.

29 June 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
MBMushk Bughio
Mushk Bughio
Muhammad Shoaib KhanMuhammad Shoaib Khan
Muhammad Shoaib Khan
Waqas Ahmed MaharWaqas Ahmed Mahar
Waqas Ahmed Mahar
TSThorsten Schuetze
Thorsten Schuetze
Electric appliances for cooling and lighting are responsible for most of the increase in electricity consumption in Karachi, Pakistan. This study aims to investigate the impact of passive energy efficiency measures (PEEMs) on the potential reduction of indoor temperature and cooling energy demand of an architectural campus building (ACB) in Karachi, Pakistan. PEEMs focus on the building envelope’s design and construction, which is a key factor of influence on a building’s cooling energy demand. The existing architectural campus building was modeled using the building information modeling (BIM) software Autodesk Revit. Data related to the electricity consumption for cooling, building masses, occupancy conditions, utility bills, energy use intensity, as well as space types, were collected and analyzed to develop a virtual ACB model. The utility bill data were used to calibrate the DesignBuilder and EnergyPlus base case models of the existing ACB. The cooling energy demand was compared with different alternative building envelope compositions applied as PEEMs in the renovation of the existing exemplary ACB. Finally, cooling energy demand reduction potentials and the related potential electricity demand savings were determined. The quantification of the cooling energy demand facilitates the definition of the building’s electricity consumption benchmarks for cooling with specific technologies.

8 April 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
MBMushk Bughio
Mushk Bughio
TSThorsten Schuetze
Thorsten Schuetze
Waqas Ahmed MaharWaqas Ahmed Mahar
Waqas Ahmed Mahar
Poor Indoor Environmental Quality (IEQ) adversely affects the performance and health of building users. Building users are an important source of information regarding IEQ and its influence on users’ wellbeing and productivity. This paper discusses the analysis and evaluation of IEQ in lecture halls of two public Architectural Campus Buildings (ACB) in Karachi, Pakistan. The method of this research is divided into three parts: (i) An analysis of local climate conditions, (ii) An on-site survey of two existing ACBs to analyze indoor environmental conditions. and (iii) The analysis of users’ satisfaction using a questionnaire survey. The research results showed that users are dissatisfied with existing hot and humid indoor environment conditions caused by interactions of local outdoor climate conditions, the building’s architecture, and inadequate ventilation within the building. The findings revealed that Karachi has 41.3% comfort hours with the warm sub-humid season to be the most comfortable season having 80.56% comfort hours. IEQ analysis unveiled that airflow in ACB1 is low, whereas, high airflow is observed in ACB2. The findings of this research unveiled that cross-ventilation by the adapted placement of openings, improved external shading devices, and provision of increased vegetation are required in both ACBs to achieve a more comfortable IEQ.

4 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
MMMohamed Elhadi Matallah
Mohamed Elhadi Matallah
Waqas Ahmed MaharWaqas Ahmed Mahar
Waqas Ahmed Mahar
MBMushk Bughio
Mushk Bughio
DADjamel Alkama
Djamel Alkama
ATEF AHRIZATEF AHRIZ
ATEF AHRIZ
SBSoumia Bouzaher
Soumia Bouzaher
Climate change and expected weather patterns in the long-term threaten the livelihood inside oases settlements in arid lands, particularly under the recurring heat waves during the harsh months. This paper investigates the impact of climate change on the outdoor thermal comfort within a multifamily housing neighborhood that is considered the most common residential archetype in Algerian Sahara, under extreme weather conditions in the summer season, in the long-term. It focuses on assessing the outdoor thermal comfort in the long-term, based on the Perceived Temperature index (PT), using simulation software ENVI-met and calculation model RayMan. Three different stations in situ were conducted and combined with TMY weather datasets for 2020 and the IPCC future projections: A1B, A2, B1 for 2050, and 2080. The results are performed from two different perspectives: to investigate how heat stress evolution undergoes climate change from 2020 till 2080; and for the development of a mathematical algorithm to predict the outdoor thermal comfort values in short-term, medium-term and long-term durations. The results indicate a gradual increase in PT index values, starting from 2020 and progressively elevated to 2080 during the summer season, which refers to an extreme thermal heat-stress level with differences in PT index averages between 2020 and 2050 (+5.9 °C), and 2080 (+7.7 °C), meaning no comfortable thermal stress zone expected during 2080. This study gives urban climate researchers, architects, designers and urban planners several insights into predicted climate circumstances and their impacts on outdoor thermal comfort for the long-term under extreme weather conditions, in order to take preventive measures for the cities’ planning in the arid regions.

26 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
MBMushk Bughio
Mushk Bughio
SBSwati Bahale
Swati Bahale
Waqas Ahmed MaharWaqas Ahmed Mahar
Waqas Ahmed Mahar
TSThorsten Schuetze
Thorsten Schuetze
Earth-to-air heat exchangers (EAHEs) are widely used to reduce the indoor temperature and associated cooling energy demand of buildings. This study investigated the potential reduction in indoor temperatures via energy-efficient ventilation through EAHEs in an existing architectural campus building (ACB) with an energy-efficient renovated building envelope in the hot and humid climate of Karachi, Pakistan. The building information modeling (BIM) program Autodesk Revit was used to develop a virtual ACB BIM model. An EnergyPlus parametric analysis of the ACB BIM model in DesignBuilder facilitated quantification of the influences of operating parameters such as pipe installation depth and pipe diameter for EAHEs with similar total pipe lengths and air-exchange rates on the performance of the EAHEs during the cooling season. A 3 m deep and 0.1 m diameter pipe layout in open space significantly reduces indoor temperature via a specific duct layout in an exemplary ACB. The results show that a pipe diameter above 0.1 m is unsuitable because of the reduction in convective heat transfer due to the increase in the pipe’s surface area and the decrease in pressure in the pipe. The findings of this study can be used to improve the indoor thermal comfort of buildings in climates with comparable properties.