Alex Virgilio¹

Dr. Alex Virgilio¹


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2020 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
AVAlex Virgilio¹
Alex Virgilio¹
ASAna Beatriz S. Silva
Ana Beatriz S. Silva
ANAna Rita Nogueira
Ana Rita Nogueira
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
GDGeorge L. Donati
George L. Donati
Multi-signal calibration methods, such as multi-energy calibration (MEC) and multi-isotope calibration (MICal), have increasingly been used to improve the efficiency of spectrochemical instrumental analyses. As MEC and MICal are adopted by an increasing number of laboratories, questions on their working ranges, the most appropriate calibration standard concentration (Cstd) to be used, and the best approach to calculate limits of detection (LOD) and quantification (LOQ) have been raised. In this study, we evaluate the effects of working with different combinations of Cstd and analyte concentration in the sample (Csam) on the accuracy of MEC and MICal. Chromium, Cu and Mo are used as models for MEC determinations by microwave-induced plasma optical emission spectrometry (MIP OES) and inductively coupled plasma OES (ICP OES), and MICal determinations by ICP mass spectrometry (ICP-MS), respectively. We use the error propagation approach to determine LODs and LOQs, evaluate the effect of employing different values of Cstd in these calculations, and compare the results with those from external standard calibration (EC) using the IUPAC approach. Finally, we apply MEC and MICal to analyze certified reference materials and compare the results with those from the traditional standard additions (SA) method. Although presenting usually higher LODs and LOQs compared to EC, MEC and MICal generally provide trueness similar to, and sometimes better than, SA. LOD and LOQ calculations based on the error propagation approach provide robust results, and trueness and precision depend on the calibration slope and the analyte level in the sample. The best results for MEC and MICal are found when working within the 0.1 < calibration slope < 0.9 range. A simple pre-analysis test comparing the analytical signal recorded for the sample (Isam) and a calibration standard (Istd) may ensure such conditions if 0.11 < Isam/Istd < 9.00. MEC and MICal are simple and efficient alternatives to EC and SA. They are particularly effective for minimizing matrix effects and analyzing complex-matrix samples.

1 December 2016 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
AVAlex Virgilio¹
Alex Virgilio¹
RARenata S. Amais
Renata S. Amais
CAClarice D.B. Amaral
Clarice D.B. Amaral
LFLucimar L. Fialho
Lucimar L. Fialho
DSDaniela Schiavo
Daniela Schiavo
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega

12 March 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
AVAlan L. Vieira
Alan L. Vieira
DGDaniel A. Gonçalves
Daniel A. Gonçalves
AVAlex Virgilio¹
Alex Virgilio¹
EFEdilene Cristina Ferreira
Edilene Cristina Ferreira
BJBradley T. Jones
Bradley T. Jones
JNJosé A. Gomes Neto
José A. Gomes Neto
Spectra of diatomic molecules are rich in fine structures which may be used for different analytical applications in high-resolution continuum source molecular absorption spectrometry (HR-CS MAS). If several bands of a given diatomic molecule are simultaneously measured, they may be used in multi-energy calibration (MEC), a method based on the use of several wavelengths of the same absorbing/emitting entity to improve the accuracy in analytical atomic spectrometry. In this work, MEC is used for the first time as a calibration method for HR-CS MAS using flame (F) and graphite furnace (GF) atomizers. Methods were developed and applied for the determination of N, P and S in fertilizers by HR-CS F MAS and Cl in milk by HR-CS GF MAS. Chlorine, N, P and S were measured via CaCl (10 band heads), NO (13 band heads), PO (13 band heads) and CS (14 band heads), respectively. No statistically significant differences were observed between Cl, N, P and S concentrations determined by MEC and by the conventional external standard calibration (paired t-test at a 95% confidence level, n = 3). Recoveries were in the 97–109% (Cl), 97–103% (P), 99–109% (S) and 98–99% (N) intervals, and the relative standard deviations (n = 12) for Cl, N, P, and S were typically 6%, 3%, 2% and 2%, respectively.

20 December 2023 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
AVAlan Lima Vieira
Alan Lima Vieira
GCGabriel Gustinelli Arantes de Carvalho
Gabriel Gustinelli Arantes de Carvalho
JNJosé Anchieta Gomes Neto
José Anchieta Gomes Neto
POPedro Vitoriano Oliveira
Pedro Vitoriano Oliveira
MKMarcos Yassuo Kamogawa
Marcos Yassuo Kamogawa
AVAlex Virgilio¹
Alex Virgilio¹
This work presents a new, robust, and reliable conductively heated digestion system with closed vessels (CHDS) for the preparation of plant materials for elemental determination by inductively coupled plasma optical emission spectrometry (ICP OES). The proposed system combines the simplicity of a 24-slot resistively heated aluminum block with the key advantages inherent to closed vessels. Fundamental studies on temperature and pressure were also performed and the difference between the liquid phase temperature (190 °C) and the aluminum block temperature (240 °C) was assigned to the dynamic condensation of the gaseous phase during digestion. The optimized digestion procedure was achieved for 250 mg test portions, 2.0 mL of HNO3 (65% v v−1), 1.5 mL of H2O2 (30% v v−1), and a temperature of 240 °C, with a heating rate of 10 °C min−1 and dwell time of 20 min. Under these conditions, the residual carbon contents in digests were generally below 700 mg L−1. The performance of the CHDS was checked by analyzing plant certified reference materials and the determined concentrations of B, Ca, Cu, Fe, K, Mg, Mn, P, S, and Zn presented no significant differences when compared to the certified values at the 95% confidence level. Recoveries in the 75–108% range and relative standard deviations ≤3% (n = 3) were typically obtained. Also, the system was applied to the analysis of sixteen samples from an interlaboratory trial, and a comparison with alternative single reaction chamber microwave-assisted digestion (SRC MWAD) and open vessel nitro-perchloric decomposition (NP) digestion methods also showed equivalence at a 95% confidence level in most cases. The CHDS system based on thermally convective heating allowed digestion of up to 24 different plant materials in ca. 50 min, but it is not limited to samples and analytes chosen in this work: the CHDS is designed for typical use in elemental inorganic analysis techniques that require liquid-based sample introduction.

6 February 2023 in Analytical Letters
Verified
Journal Article
Closed access
LTLeonardo Clemente Traversa
Leonardo Clemente Traversa
JSJoão Victor Biagi Santiago
João Victor Biagi Santiago
EOEvilim Martinez de Oliveira
Evilim Martinez de Oliveira
EFEdilene Cristina Ferreira
Edilene Cristina Ferreira
AVAlex Virgilio¹
Alex Virgilio¹
JNJosé Anchieta Gomes Neto
José Anchieta Gomes Neto
Novel applications of the closed-vessel conductively heated digestion system (CHDS) are proposed to digest biomass, biochar, oyster shell flour, bone meal and swine manure for the determination of Ca, K, Mg, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The performance of the digestion method using 14 and 7 mol L−1 HNO3 was checked by analyzing soil, rock, and plant certified reference materials (CRMs). For comparative purposes, all samples were analyzed after microwave-assisted digestion (MW-AD). Results obtained for most analytes by the closed-vessel conductively heated digestion system (CHDS) were in agreement with certified values and those attained by the comparative digestion method. The use of 7 mol L−1 HNO3 furnished lower blanks for most analytes and was effective to prepare challenging samples as biomass, biochar, shell and bone meal, swine manure, plants, soil, phosphate rock, and may be a good alternative for elemental determinations using most analytical techniques that rely on solution-based sample introduction systems. The detection limits (dry basis, mg kg−1) for Ca, Cu, Fe, K, Mg, Mn, Na, and Zn were 3, 0.4, 4, 4, 0.7, 0.4, 3, and 2, respectively. The mean relative standard deviations were close to 4.9% for closed-vessel conductively heated digestion (CHDS) and 5.9% for microwave-assisted digestion (MW-AD). Graphical Abstract

2 June 2023 in Brazilian Journal of Analytical Chemistry
Verified
Journal Article
Closed access
RCRayane Costa
Rayane Costa
JSJoão Victor Santiago
João Victor Santiago
EFEdilene Cristina Ferreira
Edilene Cristina Ferreira
AVAlex Virgilio¹
Alex Virgilio¹
JNJosé Anchieta Gomes Neto
José Anchieta Gomes Neto
The closed-vessel conductively heated digestion system (CHDS) was evaluated to digest dry dog foods for further determination of K, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The CHDS method was optimized using a fractional factorial design with five variables (HNO3 concentration, H2O2 volume, temperature, holding time, and pre-digestion time) at two levels. The accuracy of the CHDS procedure was checked by the analysis of reference materials from the National Institute of Standards and Technology (NIST SRM 1577b Bovine Liver and 2976 Mussel Tissue) and Brazilian Agricultural Research Corporation (Embrapa MR-E1002A Fish Food). Also, the digestion efficiencies were calculated from residual carbon contents (RCCs). The RCC and blank values in the CHDS digested samples were consistently low, which is suitable for determinations using ICP OES and ICP-MS techniques. For comparison, all samples were also digested by microwave-assisted digestion in closed vessels (MW-AD). Results for Na, K, Cu, Fe, Mn, and Zn determined in sample digests obtained by CHDS were not statistically different at a 95% confidence level from those observed for MW-AD. Limits of quantification (LOQ) calculated from digests in CHDS and MW-AD were comparable, and the values provided adequate limits for elemental determinations in dog foods. Data from mineral composition and moisture were employed in a clustering analysis (HCA) and the discrimination of the samples among different manufacturers and food for dogs at different life stages was possible.