Hongpeng Wu

Prof. Hongpeng Wu

Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2024 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
Kumar KinjalkKumar Kinjalk
Kumar Kinjalk
FPFrancesco Paciolla
Francesco Paciolla
BSBo Sun
Bo Sun
Andrea ZifarelliAndrea Zifarelli
Andrea Zifarelli
GMGiansergio Menduni
Giansergio Menduni
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
The precise detection of volatile organic compounds plays a pivotal role in addressing environmental concerns, industrial safety, and medical diagnostics. The accurate identification and quantification of these compounds because of their ubiquity and potential health hazards has fueled the development of advanced sensing technologies. This work presents a sensing system in the realm of long-wavelength infrared spectroscopy for achieving enhanced selectivity and sensitivity of benzene, toluene, and propane detection through quartz-enhanced photoacoustic spectroscopy. High-resolution gas spectroscopy is made possible by the use of specially designed InAs/AlSb-based quantum cascade lasers, emitting in the wavelength range 13–15 μm, and quartz tuning forks. The sensor system, characterized by its robustness and precision, demonstrates exceptional capabilities in benzene, toluene, and propane detection. The system's capacity for practical applications in environmental monitoring and medical diagnostics is demonstrated by its ability to distinguish these volatile organic compounds with a minimum detection limit of 113 ppb, 3 ppb, and 3 ppm for toluene, benzene, and propane at an integration time of 10 s, even in complex gas matrices. This work advances gas sensing technology while also offering insightful information on spectral interferences, a persistent problem in the field. The results usher in a new era of sophisticated and reliable gas sensing techniques meeting the growing demand for precise volatile organic compounds detectors for environmental monitoring purposes.

17 July 2020 in Analytical Chemistry
Verified
Journal Article
Open access
AZAndrea Zifarelli
Andrea Zifarelli
Marilena GiglioMarilena Giglio
Marilena Giglio
GMGiansergio Menduni
Giansergio Menduni
ASAngelo Sampaolo
Angelo Sampaolo
PPPietro Patimisco
Pietro Patimisco
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
We report on a statistical tool based on partial least squares regression (PLSR) able to retrieve single-component concentrations in a multiple-gas mixture characterized by absorption features spectrally overlapping. Absorption spectra of mixtures of CO-N2O and mixtures of C2H2-CH4-N2O, both diluted in N2, were detected in the mid-IR range by exploiting quartz-enhanced photoacoustic spectroscopy (QEPAS) and using two quantum cascade lasers as light sources. Single-gas reference spectra of each target mole-cule were acquired and used as PLSR-based algorithm training dataset. The concentrations range explored in the analysis varies from few of part-per-million (ppm) to thousands of ppm. Within this concentration range the influence of the gas matrix on non-radiative relaxation processes can be neglected. Exploiting the ability of PLSR to deal with correlated data, these spectra were used to generate new simulated spectra, i.e. linear combinations of the reference ones. A Gaussian noise distribution was added to the created dataset, simulating the real QEPAS signal fluctuations around the peak value. Compared with standard multilinear re-gression, PLSR predicted gas concentrations with a precision up to 5 times better, even with absorption features with spectral overlap greater than 97%.

30 August 2023 in Photoacoustics
Verified
Journal Article
Open access
BSBo Sun
Bo Sun
PPPietro Patimisco
Pietro Patimisco
ASAngelo Sampaolo
Angelo Sampaolo
AZAndrea Zifarelli
Andrea Zifarelli
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
Lei DongLei Dong
Lei Dong
We present an optical sensor based on light-induced thermoelastic spectroscopy for the detection of hydrogen sulfide (H2S) in sulfur hexafluoride (SF6). The sensor incorporates a compact multi-pass cell measuring 6 cm × 4 cm × 4 cm and utilizes a quartz tuning fork (QTF) photodetector. A 1.58 µm near-infrared distributed feedback (DFB) laser with an optical power of 30 mW serves as the excitation source. The sensor achieved a minimum detection limit (MDL) of ∼300 ppb at an integration time of 300 ms, corresponding to a normalized noise equivalent absorption coefficient (NNEA) of 3.96 × 10−9 W·cm−1·Hz−1/2. By extending the integration time to 100 s, the MDL can be reduced to ∼25 ppb. The sensor exhibits a response time of ∼1 min for a gas flow rate of 70 sccm.

7 March 2020 in Molecules
Verified
Journal Article
Open access
PDF file
YPYufeng Pan
Yufeng Pan
Lei DongLei Dong
Lei Dong
Xukun YinXukun Yin
Xukun Yin
Hongpeng WuHongpeng Wu
Hongpeng Wu
A nitrogen dioxide (NO2) photoacoustic sensor for environmental monitoring was developed using a low-cost high-power laser diode emitting at 450 nm. A compact low-noise photoacoustic detection module was designed to reduce the sensor size and to suppress noise. A LabVIEW-based control system was employed for the sensor. The parameters of the sensor were studied in detail in terms of laser power and operating pressure. The linearity of the sensor response with laser power and NO2 concentration confirms that saturation does not occur. At atmospheric pressure, a 3σ detection limit of 250 ppt (part per trillion by volume) was achieved with a 1-s averaging time, which corresponds to the specific detectivity of 3.173 × 10−9 W cm−1 Hz−1/2. A 72 h outdoor continuous on-line monitoring of environmental NO2 was implemented to demonstrate the reliability and validity of the developed NO2 sensor.

23 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SRStefano Dello Russo
Stefano Dello Russo
Marilena GiglioMarilena Giglio
Marilena Giglio
Angelo SampaoloAngelo Sampaolo
Angelo Sampaolo
Pietro PatimiscoPietro Patimisco
Pietro Patimisco
GMGiansergio Menduni
Giansergio Menduni
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
A theoretical model describing the acoustic coupling between two resonator tubes in spectrophones exploiting custom-made quartz tuning forks (QTFs) is proposed. The model is based on an open-end correction to predict the optimal tube length. A calculation of the sound field distribution from one tube exit allowed for the estimation of the optimal radius as a function of the QTF prong spacing and the sound wavelength. The theoretical predictions have been confirmed using experimental studies employing a custom QTF with a fundamental flexural mode resonance frequency of 15.8 kHz and a quality factor of 15,000 at atmospheric pressure. The spacing between the two prongs was 1.5 mm. Spectrophones mounting this QTF were implemented for the quartz-enhanced photoacoustic detection of water vapor in air in the mid-infrared spectral range.

10 June 2024 in Photoacoustics
Verified
Journal Article
Open access
AZAndrea Zifarelli
Andrea Zifarelli
GNGiuseppe Negro
Giuseppe Negro
LMLavinia A. Mongelli
Lavinia A. Mongelli
ASAngelo Sampaolo
Angelo Sampaolo
EREzio Ranieri
Ezio Ranieri
Vincenzo SpagnoloVincenzo Spagnolo
Vincenzo Spagnolo
Here we present a computational and experimental fluid dynamics study for the characterization of the flow field within the gas chamber of a Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) sensor, at different flow rates at the inlet of the chamber. The transition from laminar to turbulent regime is ruled both by the inlet flow conditions and dimension of the gas chamber. The study shows how the distribution of the flow field in the chamber can influence the QEPAS sensor sensitivity, at different operating pressures. When turbulences and eddies are generated within the gas chamber, the efficiency of photoacoustic generation is significantly altered.