Pascal Borzée

Pascal Borzée


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2018 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MDMargot Deviaene
Margot Deviaene
DTDries Testelmans
Dries Testelmans
BBBertien Buyse
Bertien Buyse
PBPascal Borzée
Pascal Borzée
SHSabine Van Huffel
Sabine Van Huffel
CVCarolina Varon
Carolina Varon
$Objective:$ This paper presents a methodology to automatically screen for sleep apnea based on the detection of apnea and hypopnea events in the blood oxygen saturation (SpO $_{2}$ ) signal. $Methods:$ It starts by detecting all desaturations in the SpO $_{2}$ signal. From these desaturations, a total of 143 time-domain features are extracted. After feature selection, the six most discriminative features are used to construct classifiers to predict if desaturations are caused by respiratory events. From these, a random forest classifier yielded the best classification performance. The number of desaturations, classified as caused by respiratory events per hour of recording can then be used as an estimate of the apnea-hypopnea index (AHI), and to predict if a patient suffers from sleep apnea-hypopnea syndrome (SAHS) or not. All classifiers were developed based on a subset of 500 subjects of the Sleep Heart Health Study (SHHS) and tested on three different datasets, containing 8052 subjects in total. $Results:$ An averaged desaturation classification accuracy of 82.8 % was achieved over the different test sets. Subjects having SAHS with an AHI larger than 15 can be detected with an average accuracy of 87.6 %. $Conclusion:$ The achieved SAHS screening outperforms SpO $_{2}$ methods from the literature on the SHHS test dataset. Moreover, the robustness of the method was shown when tested on different independent test sets. $Significance:$ These results show that an algorithm based on simple features of SpO $_{2}$ desaturations can outperform more elaborate methods in the detection of apneic events and the screening of SAHS patients.

8 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
DHDorien Huysmans
Dorien Huysmans
PBPascal Borzée
Pascal Borzée
DTDries Testelmans
Dries Testelmans
BBBertien Buyse
Bertien Buyse
TWTim Willemen
Tim Willemen
CVCarolina Varon
Carolina Varon
There exists a technological momentum towards the development of unobtrusive, simple, and reliable systems for long-term sleep monitoring. An off-the-shelf commercial pressure sensor meeting these requirements is the Emfit QS. First, the potential for sleep apnea screening was investigated by revealing clusters of contaminated and clean segments. A relationship between the irregularity of the data and the sleep apnea severity class was observed, which was valuable for screening (sensitivity 0.72, specificity 0.70), although the linear relation was limited ( R 2 of 0.16). Secondly, the study explored the suitability of this commercial sensor to be merged with gold standard polysomnography data for future sleep monitoring. As polysomnography (PSG) and Emfit signals originate from different types of sensor modalities, they cannot be regarded as strictly coupled. Therefore, an automated synchronization procedure based on artefact patterns was developed. Additionally, the optimal position of the Emfit for capturing respiratory and cardiac information similar to the PSG was identified, resulting in a position as close as possible to the thorax. The proposed approach demonstrated the potential for unobtrusive screening of sleep apnea patients at home. Furthermore, the synchronization framework enabled supervised analysis of the commercial Emfit sensor for future sleep monitoring, which can be extended to other multi-modal systems that record movements during sleep.

23 July 2021 in Entropy
Verified
Journal Article
Open access
PDF file
ARAndrea Rozo
Andrea Rozo
JTJohn Fredy Morales Tellez
John Fredy Morales Tellez
JMJonathan Moeyersons
Jonathan Moeyersons
RJRohan Joshi
Rohan Joshi
Enrico Gianluca CaianiEnrico Gianluca Caiani
Enrico Gianluca Caiani
CVCarolina Varon
Carolina Varon
Transfer entropy (TE) has been used to identify and quantify interactions between physiological systems. Different methods exist to estimate TE, but there is no consensus about which one performs best in specific applications. In this study, five methods (linear, k-nearest neighbors, fixed-binning with ranking, kernel density estimation and adaptive partitioning) were compared. The comparison was made on three simulation models (linear, nonlinear and linear + nonlinear dynamics). From the simulations, it was found that the best method to quantify the different interactions was adaptive partitioning. This method was then applied on data from a polysomnography study, specifically on the ECG and the respiratory signals (nasal airflow and respiratory effort around the thorax). The hypothesis that the linear and nonlinear components of cardio-respiratory interactions during light and deep sleep change with the sleep stage, was tested. Significant differences, after performing surrogate analysis, indicate an increased TE during deep sleep. However, these differences were found to be dependent on the type of respiratory signal and sampling frequency. These results highlight the importance of selecting the appropriate signals, estimation method and surrogate analysis for the study of linear and nonlinear cardio-respiratory interactions.

25 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DHDorien Huysmans
Dorien Huysmans
ICIvan Castro
Ivan Castro
PBPascal Borzée
Pascal Borzée
APAakash Patel
Aakash Patel
TTTom Torfs
Tom Torfs
CVCarolina Varon
Carolina Varon
Obstructive sleep apnea (OSA) patients would strongly benefit from comfortable home diagnosis, during which detection of wakefulness is essential. Therefore, capacitively-coupled electrocardiogram (ccECG) and bioimpedance (ccBioZ) sensors were used to record the sleep of suspected OSA patients, in parallel with polysomnography (PSG). The three objectives were quality assessment of the unobtrusive signals during sleep, prediction of sleep–wake using ccECG and ccBioZ, and detection of high-risk OSA patients. First, signal quality indicators (SQIs) determined the data coverage of ccECG and ccBioZ. Then, a multimodal convolutional neural network (CNN) for sleep–wake prediction was tested on these preprocessed ccECG and ccBioZ data. Finally, two indices derived from this prediction detected patients at risk. The data included 187 PSG recordings of suspected OSA patients, 36 (dataset “Test”) of which were recorded simultaneously with PSG, ccECG, and ccBioZ. As a result, two improvements were made compared to prior studies. First, the ccBioZ signal coverage increased significantly due to adaptation of the acquisition system. Secondly, the utility of the sleep–wake classifier increased as it became a unimodal network only requiring respiratory input. This was achieved by using data augmentation during training. Sleep–wake prediction on “Test” using PSG respiration resulted in a Cohen’s kappa (κ) of 0.39 and using ccBioZ in κ = 0.23. The OSA risk model identified severe OSA patients with a κ of 0.61 for PSG respiration and κ of 0.39 using ccBioZ (accuracy of 80.6% and 69.4%, respectively). This study is one of the first to perform sleep–wake staging on capacitively-coupled respiratory signals in suspected OSA patients and to detect high risk OSA patients based on ccBioZ. The technology and the proposed framework could be applied in multi-night follow-up of OSA patients.

1 November 2021 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
JTJohn Fredy Morales Tellez
John Fredy Morales Tellez
JMJonathan Moeyersons
Jonathan Moeyersons
DTDries Testelmans
Dries Testelmans
BBBertien Buyse
Bertien Buyse
PBPascal Borzée
Pascal Borzée
CVCarolina Varon
Carolina Varon
Background. Respiratory sinus arrhythmia (RSA) is a form of cardiorespiratory coupling. Its quantification has been suggested as a biomarker to diagnose different diseases. Two state-of-the-art methods, based on subspace projections and entropy, are used to estimate the RSA strength and are evaluated in this paper. Their computation requires the selection of a model order, and their performance is strongly related to the temporal and spectral characteristics of the cardiorespiratory signals. Objective. To evaluate the robustness of the RSA estimates to the selection of model order, delays, changes of phase and irregular heartbeats as well as to give recommendations for their interpretation on each case. Approach. Simulations were used to evaluate the model order selection when calculating the RSA estimates introduced before, as well as three different scenarios that can occur in signals acquired in non-controlled environments and/or from patient populations: the presence of irregular heartbeats; the occurrence of delays between heart rate variability (HRV) and respiratory signals; and the changes over time of the phase between HRV and respiratory signals. Main results. It was found that using a single model order for all the calculations suffices to characterize RSA correctly. In addition, the RSA estimation in signals containing more than 5 irregular heartbeats in a period of 5 min might be misleading. Regarding the delays between HRV and respiratory signals, both estimates are robust. For the last scenario, the two approaches tolerate phase changes up to 54°, as long as this lasts less than one fifth of the recording duration. Significance. Guidelines are given to compute the RSA estimates in non-controlled environments and patient populations.

27 October 2021
Verified
Book Chapter
Closed access
PDF file
MDMargot Deviaene
Margot Deviaene
DHDorien Huysmans
Dorien Huysmans
ICIvan Castro
Ivan Castro
PBPascal Borzée
Pascal Borzée
DTDries Testelmans
Dries Testelmans
CVCarolina Varon
Carolina Varon