The ORION chipset, a full-custom multichip readout and processing electronics for the X- $\gamma $ -ray imaging spectrometer (XGIS) on-board the transient high-energy sky and early universe surveyor (THESEUS) space mission, is presented. The XGIS detection plane is arranged in a matrix of 10 $\times $ 10 detection modules, each one composed of 64 CsI(Tl) scintillation bars (4.5 mm $\times $ 4.5 mm $\times $ 30 mm) optically coupled at the top and bottom ends to two 8 $\times $ 8 monolithic silicon drift detector (SDD) matrices. The top SDD, exposed to the X-ray entrance window, performs the double function of low-energy X-ray detection as well as scintillator’s readout, together with the bottom SDD, providing detection and spectroscopic energy range from 2 keV up to 20 MeV. The need to achieve a high-energy resolution, as well as a high sensitive area on the detection plane, led to the development of a chipset organized to have a minimum-area analog readout chip placed in close proximity of the SDD (ORION-FE) and a mixed-signal back-end (ORION-BE) placed a few centimeters further on the back-end board for the additional signal processing and digitization. The multichip readout electronics integrates two dedicated analog processors for low-energy photons up to 30 keV (X-processor) and high-energy photons up to 5 MeV ( $\gamma $ -processor), allowing a spectroscopy-grade resolution in the 4 decades energy band (2 keV–20 MeV) of the XGIS, with a simulated power consumption of 1.55 mW/pixel. The ORION prototype was bonded to two ~25 mm 2 SDDs, and extensively characterized in terms of pulse shaping, pulse discrimination, and stretching functionality, as well as linearity, dynamic range, and spectroscopic resolution. An optimum equivalent noise charge (ENC) at −20 °C of 24.3 el. r.m.s. on the X-channel [212 eV full-width at half-maximum (FWHM) on Si], and 39.6 el. r.m.s. on the $\gamma $ -channel [3.7 keV FWHM on CsI(Tl)] has been recorded.
18 October 2021 in Journal of Synchrotron Radiation
X-ray absorption fine-structure (XAFS) spectroscopy can assess the chemical speciation of the elements providing their coordination and oxidation state, information generally hidden to other techniques. In the case of trace elements, achieving a good quality XAFS signal poses several challenges, as it requires high photon flux, counting statistics and detector linearity. Here, a new multi-element X-ray fluorescence detector is presented, specifically designed to probe the chemical speciation of trace 3d elements down to the p.p.m. range. The potentialities of the detector are presented through a case study: the speciation of ultra-diluted elements (Fe, Mn and Cr) in geological rocks from a calcareous formation related to the dispersal processes from Ontong (Java) volcanism (mid-Cretaceous). Trace-elements speciation is crucial in evaluating the impact of geogenic and anthropogenic harmful metals on the environment, and to evaluate the risks to human health and ecosystems. These results show that the new detector is suitable for collecting spectra of 3d elements in trace amounts in a calcareous matrix. The data quality is high enough that quantitative data analysis could be performed to determine their chemical speciation.
The search for low-energy antideuterons in cosmic rays allows the addressing of fundamental physics problems testing for the presence of primordial antimatter and the nature of Dark Matter. The PHeSCAMI (Pressurized Helium Scintillating Calorimeter for AntiMatter Identification) project aims to exploit the long-living metastable states of the helium target for the identification of low-energy antideuterons in cosmic rays. A space-based pressurized helium calorimeter would provide a characteristic identification signature based on the coincident detection of a prompt scintillation signal emitted by the antideuteron energy loss during the slowing-down phase in the gas, and the (≈µs) delayed scintillation signal provided by the charged pions produced in the subsequent annihilation. The performance of a high-pressure (200-bar) helium scintillator prototype, tested in the INFN-TIFPA laboratory, will be summarized.
3 June 2013 in IEEE Transactions on Nuclear Science
Apsel4well is a monolithic active pixel sensor (MAPS) chip intended for application to fast and low material silicon vertex trackers for future experiments at high intensity machines. The design is based on a 180 nm CMOS process with quadruple well option called INMAPS. This technology makes it possible to increase the in-pixel intelligence as compared to standard three transistor MAPS and their variants. Moreover, the availability of a high resistivity epitaxial layer is confirmed to lead to further improvements in terms of charge collection performance and radiation resistance. This paper, after providing some details on the INMAPS process, focuses on the analog front-end section of the pixel readout chain. Measurement results on the main analog channel parameters, like charge sensitivity and equivalent noise charge, are given along with charge collection properties evaluation through 90 Sr/ 90 Y spectrum measurements and laser stimulation. Characterization data were also used for validating a TCAD model of the device. Finally, selected results from a neutron irradiation campaign with fluences up to 2.7 × 10 13 1 MeV neutron equivalent/cm 2 will be shown.
3 June 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment