Maarten Cauwe

Dr. Maarten Cauwe

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2019 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
TDThomas Deckmyn
Thomas Deckmyn
MCMaarten Cauwe
Maarten Cauwe
DGDries Vande Ginste
Dries Vande Ginste
Hendrik RogierHendrik Rogier
Hendrik Rogier
SASam Agneessens
Sam Agneessens
A novel dual-band substrate-integrated waveguide (SIW) antenna array topology is proposed for operation in the 28 and 38 GHz frequency bands. Four miniaturized quarter-mode SIW cavities are tightly coupled, causing mode bifurcation, and yielding an antenna topology with four distinct resonance frequencies. A pair of resonances is assigned to both the 28 and 38 GHz band, achieving wideband operation in both frequency ranges. Moreover, owing to the exploited miniaturization technique, an extremely compact array topology is obtained, facilitating easy and straightforward integration. The computer-aided design process yields a four-element antenna array that entirely covers the 28 GHz band (27.5–29.5 GHz) and 38 GHz band (37.0–38.6 GHz) with a measured impedance bandwidth of 3.65 and 2.19 GHz, respectively. A measured broadside gain of 10.1 dBi, a radiation efficiency of 75.75% and a 3 dB beamwidth of 25° are achieved in the 28 GHz band. Moreover, in the 38 GHz band, the measured broadside gain amounts to 10.2 dBi, a radiation efficiency of 70.65% is achieved, and the 3 dB beamwidth is 20°.

6 October 2017 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
TDThomas Deckmyn
Thomas Deckmyn
SASam Agneessens
Sam Agneessens
ARAd C. F. Reniers
Ad C. F. Reniers
BSBart Smolders
Bart Smolders
MCMaarten Cauwe
Maarten Cauwe
Hendrik RogierHendrik Rogier
Hendrik Rogier
A novel wideband substrate integrated waveguide (SIW) antenna topology, consisting of coupled half-mode and quarter-mode SIW resonant cavities, is proposed for operation in the 60 GHz band. This innovative topology combines a considerable bandwidth enhancement and a low form factor with compatibility with low-cost printed circuit board manufacturing processes, making it excellently suited for the next generation, high data rate wireless applications. Moreover, exploiting SIW technology, a high antenna-platform isolation is obtained, enabling dense integration with active electronics without harmful coupling. The computer-aided design process yields an antenna that covers the entire 57–64 GHz IEEE 802.11ad band with a measured fractional impedance bandwidth of 11.7% (7 GHz). The measured maximum gain and radiation efficiency of the prototype are larger than 5.1 dBi and 65%, respectively, within the entire impedance bandwidth.

11 December 2020 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
IPIgor Lima de Paula
Igor Lima de Paula
SLSam Lemey
Sam Lemey
DBDries Bosman
Dries Bosman
QBQuinten Van Den Brande
Quinten Van Den Brande
OCOlivier Caytan
Olivier Caytan
ILIgor Limadepaula
Igor Limadepaula
A cost-effective, compact and high-performance antenna element for beamforming applications in all 5G New Radio bands in the [24.25-29.5] GHz spectrum is proposed. The novel antenna topology adopts a square patch, an edge-plated air-filled cavity, and an hourglass-shaped aperture-coupled feed to achieve a very high efficiency over a wide frequency band in a compact footprint ${(0.48\lambda_{0}\times0.48\lambda_{0})}$ . Its compliance with standard PCB fabrication technology, without complex multi-layer PCB stack, ensures low-cost fabrication. The antenna feedplane offers a platform for compact integration of active electronic circuitry. Two different modular 1×4 antenna arrays were realized to demonstrate its suitability for broadband multi-antenna systems. Measurements of the fabricated antenna element and the antenna array prototypes revealed a -10-dB impedance bandwidth of 7.15 GHz (26.8%) and 8.2 GHz (30.83%), resp. The stand-alone antenna features a stable peak gain of 7.4±0.6 dBi in the [24.25- 29.5] GHz band and a measured total efficiency of at least 86%. The 1±4 array features a peak gain of 10.1±0.7 dBi and enables grating-lobe-free beamsteering from -50° to 50°.

12 September 2019 in Coatings
Verified
Journal Article
Open access
PDF file
CLChangzheng Li
Changzheng Li
MCMaarten Cauwe
Maarten Cauwe
YYYang Yang
Yang Yang
David SchaubroeckDavid Schaubroeck
David Schaubroeck
LMLothar Mader
Lothar Mader
MBMaaike Op de Beeck
Maaike Op de Beeck
Long-term packaging of miniaturized, flexible implantable medical devices is essential for the next generation of medical devices. Polymer materials that are biocompatible and flexible have attracted extensive interest for the packaging of implantable medical devices, however realizing these devices with long-term hermeticity up to several years remains a great challenge. Here, polyimide (PI) based hermetic encapsulation was greatly improved by atomic layer deposition (ALD) of a nanoscale-thin, biocompatible sandwich stack of HfO2/Al2O3/HfO2 (ALD-3) between two polyimide layers. A thin copper film covered with a PI/ALD-3/PI barrier maintained excellent electrochemical performance over 1028 days (2.8 years) during acceleration tests at 60 °C in phosphate buffered saline solution (PBS). This stability is equivalent to approximately 14 years at 37 °C. The coatings were monitored in situ through electrochemical impedance spectroscopy (EIS), were inspected by microscope, and were further analyzed using equivalent circuit modeling. The failure mode of ALD Al2O3, ALD-3, and PI soaking in PBS is discussed. Encapsulation using ultrathin ALD-3 combined with PI for the packaging of implantable medical devices is robust at the acceleration temperature condition for more than 2.8 years, showing that it has great potential as reliable packaging for long-term implantable devices.

26 December 2019 in Coatings
Verified
Journal Article
Open access
PDF file
CLChangzheng Li
Changzheng Li
MCMaarten Cauwe
Maarten Cauwe
LMLothar Mader
Lothar Mader
David SchaubroeckDavid Schaubroeck
David Schaubroeck
MBMaaike Op de Beeck
Maaike Op de Beeck
Barrier layers for the long-term encapsulation of implantable medical devices play a crucial role in the devices’ performance and reliability. Typically, to understand the stability and predict the lifetime of barriers (therefore, the implantable devices), the device is subjected to accelerated testing at higher temperatures compared to its service parameters. Nevertheless, at high temperatures, reaction and degradation mechanisms might be different, resulting in false accelerated test results. In this study, the maximum valid temperatures for the accelerated testing of two barrier layers were investigated: atomic layer deposited (ALD) Al2O3 and stacked ALD HfO2/Al2O3/HfO2, hereinafter referred to as ALD-3. The in-house developed standard barrier performance test is based on continuous electrical resistance monitoring and microscopic inspection of Cu patterns covered with the barrier and immersed in phosphate buffered saline (PBS) at temperatures up to 95 °C. The results demonstrate the valid temperature window to perform temperature acceleration tests. In addition, the optimized ALD layer in combination with polyimide (polyimide/ALD-3/polyimide) works as effective barrier at 60 °C for 1215 days, suggesting the potential applicability to the encapsulation of long-term implants.

24 November 2021 in CEAS Space Journal
Verified
Journal Article
Closed access
PDF file
MCMaarten Cauwe
Maarten Cauwe
BVBart Vandevelde
Bart Vandevelde
CNChinmay Nawghane
Chinmay Nawghane
MSMarnix Van De Slyeke
Marnix Van De Slyeke
ACAlexia Coulon
Alexia Coulon
SHStan Heltzel
Stan Heltzel