Maaike Op de Beeck

Prof. Dr. Maaike Op de Beeck

1. Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, 9000 Gent, Belgium
+1

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
YCYun-Hsuan Chen
Yun-Hsuan Chen
MBMaaike Op de Beeck
Maaike Op de Beeck
LVLuc Vanderheyden
Luc Vanderheyden
ECEvelien Carrette
Evelien Carrette
Vojkan MihajlovićVojkan Mihajlović
Vojkan Mihajlović
CHChris Van Hoof
Chris Van Hoof
Conventional gel electrodes are widely used for biopotential measurements, despite important drawbacks such as skin irritation, long set-up time and uncomfortable removal. Recently introduced dry electrodes with rigid metal pins overcome most of these problems; however, their rigidity causes discomfort and pain. This paper presents dry electrodes offering high user comfort, since they are fabricated from EPDM rubber containing various additives for optimum conductivity, flexibility and ease of fabrication. The electrode impedance is measured on phantoms and human skin. After optimization of the polymer composition, the skin-electrode impedance is only ~10 times larger than that of gel electrodes. Therefore, these electrodes are directly capable of recording strong biopotential signals such as ECG while for low-amplitude signals such as EEG, the electrodes need to be coupled with an active circuit. EEG recordings using active polymer electrodes connected to a clinical EEG system show very promising results: alpha waves can be clearly observed when subjects close their eyes, and correlation and coherence analyses reveal high similarity between dry and gel electrode signals. Moreover, all subjects reported that our polymer electrodes did not cause discomfort. Hence, the polymer-based dry electrodes are promising alternatives to either rigid dry electrodes or conventional gel electrodes.

12 September 2019 in Coatings
Verified
Journal Article
Open access
PDF file
CLChangzheng Li
Changzheng Li
MCMaarten Cauwe
Maarten Cauwe
YYYang Yang
Yang Yang
David SchaubroeckDavid Schaubroeck
David Schaubroeck
LMLothar Mader
Lothar Mader
MBMaaike Op de Beeck
Maaike Op de Beeck
Long-term packaging of miniaturized, flexible implantable medical devices is essential for the next generation of medical devices. Polymer materials that are biocompatible and flexible have attracted extensive interest for the packaging of implantable medical devices, however realizing these devices with long-term hermeticity up to several years remains a great challenge. Here, polyimide (PI) based hermetic encapsulation was greatly improved by atomic layer deposition (ALD) of a nanoscale-thin, biocompatible sandwich stack of HfO2/Al2O3/HfO2 (ALD-3) between two polyimide layers. A thin copper film covered with a PI/ALD-3/PI barrier maintained excellent electrochemical performance over 1028 days (2.8 years) during acceleration tests at 60 °C in phosphate buffered saline solution (PBS). This stability is equivalent to approximately 14 years at 37 °C. The coatings were monitored in situ through electrochemical impedance spectroscopy (EIS), were inspected by microscope, and were further analyzed using equivalent circuit modeling. The failure mode of ALD Al2O3, ALD-3, and PI soaking in PBS is discussed. Encapsulation using ultrathin ALD-3 combined with PI for the packaging of implantable medical devices is robust at the acceleration temperature condition for more than 2.8 years, showing that it has great potential as reliable packaging for long-term implantable devices.

26 December 2019 in Coatings
Verified
Journal Article
Open access
PDF file
CLChangzheng Li
Changzheng Li
MCMaarten Cauwe
Maarten Cauwe
LMLothar Mader
Lothar Mader
David SchaubroeckDavid Schaubroeck
David Schaubroeck
MBMaaike Op de Beeck
Maaike Op de Beeck
Barrier layers for the long-term encapsulation of implantable medical devices play a crucial role in the devices’ performance and reliability. Typically, to understand the stability and predict the lifetime of barriers (therefore, the implantable devices), the device is subjected to accelerated testing at higher temperatures compared to its service parameters. Nevertheless, at high temperatures, reaction and degradation mechanisms might be different, resulting in false accelerated test results. In this study, the maximum valid temperatures for the accelerated testing of two barrier layers were investigated: atomic layer deposited (ALD) Al2O3 and stacked ALD HfO2/Al2O3/HfO2, hereinafter referred to as ALD-3. The in-house developed standard barrier performance test is based on continuous electrical resistance monitoring and microscopic inspection of Cu patterns covered with the barrier and immersed in phosphate buffered saline (PBS) at temperatures up to 95 °C. The results demonstrate the valid temperature window to perform temperature acceleration tests. In addition, the optimized ALD layer in combination with polyimide (polyimide/ALD-3/polyimide) works as effective barrier at 60 °C for 1215 days, suggesting the potential applicability to the encapsulation of long-term implants.

30 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
EAEsmaeil Afshari
Esmaeil Afshari
SHSamer Houri
Samer Houri
RVRik Verplancke
Rik Verplancke
VRVeronique Rochus
Veronique Rochus
MCMaarten Cauwe
Maarten Cauwe
MBMaaike Op de Beeck
Maaike Op de Beeck
The motivation of this work is to enable the use of piezoelectric micromachined ultrasonic transducer (PMUT)-based implants within the human body for biomedical applications, particularly for power and data transfer for implanted medical devices. To protect surrounding tissue and ensure PMUT functionality over time, biocompatible and hermetic encapsulation is essential. This study investigates the impact of Parylene F-VT4 layers of various thicknesses as well as the effect of multilayer stacks of Parylene F-VT4 combined with atomic layer-deposited nanolayers of Al2O3 and HfO2 on the mechanical and acoustic properties of PMUTs. PMUTs with various diameters (40 µm, 60 µm, and 80 µm) are fabricated and tested both as stand-alone devices and as arrays. The mechanical behavior of single stand-alone PMUT devices is characterized in air and in water using laser Doppler vibrometry (LDV), while the acoustic output of arrays is evaluated by pressure measurements in water. Experimental results reveal a non-monotonic change in resonance frequency as a function of increasing encapsulation thickness due to the competing effects of added mass and increased stiffness. The performance of PMUT arrays is clearly influenced by the encapsulation. For certain array designs, the encapsulation significantly improved the arrays’ pressure output, a change that is attributed to the change in the acoustic wavelength and inter-element coupling. These findings highlight the impact of encapsulation in modifying and potentially enhancing PMUT performance.

28 May 2025 in Coatings
Verified
Journal Article
Open access
PDF file
EAEsmaeil Afshari
Esmaeil Afshari
RVRik Verplancke
Rik Verplancke
MCMaarten Cauwe
Maarten Cauwe
MBMaaike Op de Beeck
Maaike Op de Beeck
This study comprehensively examines the barrier properties, aging behavior, and failure mechanisms of Parylene F-VT4 films, applied at four distinct thicknesses (0.3 µm, 0.6 µm, 0.9 µm, and 1.2 µm), as encapsulation layers for implantable medical devices. Parylene F-VT4, a fluorinated polymer known for its mechanical flexibility, thermal stability, and chemical inertness, is a promising candidate for long-term hermetic encapsulation. Parylene F-VT4 was uniformly deposited via a dedicated chemical vapor deposition (CVD) process typically used for Parylene depositions. The investigation of the Parylene F-VT4 films included pinhole density characterization, electrochemical impedance spectroscopy (EIS), and testing of coating lifetime based on the resistance of Cu meanders protected by Parylene F-VT4 when immersed in phosphate-buffered saline (PBS) under accelerated aging conditions (PBS at 60 °C) over 550 days. The EIS results demonstrated that thicker coatings (1.2 µm) exhibited excellent barrier properties and resistance to electrolyte penetration, whereas thinner coatings (0.3 µm and 0.6 µm) showed more rapid degradation due to microvoids and pinholes. The temporal evaluation of EIS spectra highlighted the gradual decrease in impedance magnitude, indicating the ingress of ions and water into the coating. The lifetime in PBS at 60 °C was determined by resistance-based lifetime measurements on Cu meander structures coated with Parylene F-VT4 coatings. The lifetime at 37 °C was calculated, assuming an acceleration factor of 2 per 10 °C increase in temperature, yielding lifetimes of approximately 25 days, 6.4 months, 2.3 years, and 4.5 years for 0.3 µm, 0.6 µm, 0.9 µm, and 1.2 µm coatings, respectively. These findings highlight the critical relationship between thickness and durability, providing valuable insights into the long-term performance of thin Parylene F-VT4 films for implantable devices.

1 March 2025 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
FGFrancesco Grassi
Francesco Grassi
CCCharlotte Cums
Charlotte Cums
DCDieter Cuypers
Dieter Cuypers
RVRik Verplancke
Rik Verplancke
TVThijs Vackier
Thijs Vackier
MBMaaike Op de Beeck
Maaike Op de Beeck
Electrochemical impedance spectroscopy (EIS) has been established as an effective technique for bacterial biofilm detection. Through the need for miniaturization, the application of novel electrode materials gains interest. In this study, we introduce Sputtered IRidium Oxide Film (SIROF) electrodes of varying sizes and geometries as sensors for biofilm detection. Pre-emptive cyclic voltammetry (pre-cycling) was used to transform as-sputtered anhydrous iridium oxide films into hydroxides, reducing the impedance and allowing the material to be adopted for miniaturized biofilm sensors. Our investigation showed that especially lower scan rates during this pre-cycling process reduced the interfacial impedance, hence optimizing electrode performance for this application. Using EIS in combination with pre-cycled SIROF electrodes, we detected biofilm growth within 24 hours and successfully distinguished between biofilms of S. aureus and P. aeruginosa. Additionally, we analyzed the influence of electrode size on biofilm detection and characterization. This study highlights SIROF electrodes as a promising platform for sensitive and scalable biofilm monitoring.