This work presents the development of a MEMS nanoindenter that uses exchangeable AFM probes for quasi-static nanomechanical characterization of compliant and ultra-compliant materials. While the electrostatic micro-force transducer of the MEMS nanoindenter provides a maximum indentation depth up to 9.5 µm with a maximum output force of 600 µN, experimental investigations reveal that it can achieve a depth and force resolution better than 4 pm/sqrt(Hz) and 0.3 nN/sqrt(Hz), in air for f ≥ 1 Hz. A passive AFM probe gripper is integrated into the MEMS nanoindenter, allowing the nanoindenter to utilize various AFM probes as an indenter for material testing. A proof-of-principle experimental setup has been built to investigate the performance of the MEMS nanoindenter prototype. In proof-of-principle experiments, the prototype with a clamped diamond AFM probe successfully identified an atomic step (~0.31 nm) within a Si ultraflat sample using the scanning probe microscopy mode. The nanomechanical measurement capability of the MEMS nanoindenter prototype has been verified by means of measurements of reference polymer samples using a silicon AFM probe and by means of measurements of the elastic properties of a PDMS sample using a spherical diamond-coated AFM probe. Owing to its compact and low-cost but high-resolution capacitive readout system, this MEMS nanoindenter head can be further applied for in-situ quantitative nanomechanical measurements in AFMs and SEMs.
A method named lateral scanning confocal microscopy (LtSCM) is proposed with the aim of determining the in-plane displacement of microstructures, especially of those moving components within microelectromechanical systems (MEMS) actuators and sensors, which feature high aspect ratio and limited geometrical size in one or two dimensions within the surface plane. The principle of the LtSCM is presented and theoretically analyzed, which indicates that the LtSCM has the potential to determine with high resolution the in-plane displacement, position, and even the geometrical size of the object. Furthermore, in the case of in-plane displacement measurement, the measurement resolution of the LtSCM should be insensitive to the dynamic performance of the movable microstructures, i.e., from quasi-static to ultrahigh speed. In a proof-of-principle experiment, the voltage-displacement response of an electrostatic comb-drive actuator has been obtained with nanometric resolution.
27 April 2020 in Measurement Science and Technology
We designed and developed a new instrument for calibrating micro-force sensors. The calibration is traceable to the SI unit of mass and is realized from 1 µN–60 mN by means of electromagnetic force compensation of a balance. The expanded measurement uncertainty of our instrument comprises two contributions, an absolute contribution of 0.13 µN and a relative contribution of 2700 ppm. We verified our instrument in a bilateral comparison between METAS and PTB's instruments for forces from 40 µN up to 20 mN. The degrees of equivalence found by the two institutes are in excellent agreement.
In this work, we present the area-selective growth of zinc oxide nanowire (NW) arrays on patterned surfaces of a silicon (Si) substrate for a piezoelectric nanogenerator (PENG). ZnO NW arrays were selectively grown on patterned surfaces of a Si substrate using a devised microelectromechanical system (MEMS)-compatible chemical bath deposition (CBD) method. The fabricated devices measured a maximum peak output voltage of ~7.9 mV when a mass of 91.5 g was repeatedly manually placed on them. Finite element modeling (FEM) of a single NW using COMSOL Multiphysics at an applied axial force of 0.9 nN, which corresponded to the experimental condition, resulted in a voltage potential of −6.5 mV. The process repeated with the same pattern design using a layer of SU-8 polymer on the NWs yielded a much higher maximum peak output voltage of ~21.6 mV and a corresponding peak power density of 0.22 µW/cm3, independent of the size of the NW array. The mean values of the measured output voltage and FEM showed good agreement and a nearly linear dependence on the applied force on a 3 × 3 µm2 NW array area in the range of 20 to 90 nN.
High-speed tactile roughness measurements set high demand on the trackability of the stylus probe. Because of the features of low mass, low probing force, and high signal linearity, the piezoresistive silicon microprobe is a hopeful candidate for high-speed roughness measurements. This paper investigates the trackability of these microprobes through building a theoretical dynamic model, measuring their resonant response, and performing tip-flight experiments on surfaces with sharp variations. Two microprobes are investigated and compared: one with an integrated silicon tip and one with a diamond tip glued to the end of the cantilever. The result indicates that the microprobe with the silicon tip has high trackability for measurements up to traverse speeds of 10 mm/s, while the resonant response of the microprobe with diamond tip needs to be improved for the application in high-speed topography measurements.
The search for a synthesis method to create longer ZnO NWAs with high-quality vertical alignment, and the investigation of their electrical properties, have become increasingly important. In this study, a hydrothermal method for growing vertically aligned arrays of ZnO nanowires (NWs) using localized heating was utilized. To produce longer NWs, the temperature environment of the growth system was optimized with a novel reaction container that provided improved thermal insulation. At a process temperature above ~90 °C, ZnO NWs reached a length of ~26.8 µm within 24 h, corresponding to a growth rate of 1.1 µm/h, nearly double the rate of 0.6 µm/h observed in traditional chemical bath growth using a glass reactor. The densely grown NWs (~1.9/µm2), with a diameter of ~0.65 µm, exhibited a preferred hexagonal c-axis orientation and were vertically aligned to the (100) silicon (Si) substrate. These NW structures have multiple applications, e.g., in piezotronic strain sensors, gas sensing, and piezoelectric energy harvesting. As proof of concept, a piezoelectric nanogenerator (PENG) was fabricated by embedding the NWs in an S1818 polymer matrix over a 15 mm × 15 mm area. Under repeated impulse-type compressive forces of 0.9 N, a maximum peak output voltage of ~95.9 mV was recorded, which is higher by a factor of four to five than the peak output voltage of 21.6 mV previously obtained with NWs measuring ~1.8 µm in length.