Szymon Barczentewicz

Dr. Szymon Barczentewicz

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KDKrzysztof Duda
Krzysztof Duda
TZTomasz P. Zielinski
Tomasz P. Zielinski
Andrzej BienAndrzej Bien
Andrzej Bien
SBSzymon Barczentewicz
Szymon Barczentewicz
The IEEE Std C37.118.1(a) describes synchrophasor measurement by Phasor Measurement Unit (PMU) for the system fundamental frequency. Harmonic synchrophasor, i.e. synchrophasor measured for harmonic frequencies, is not considered in the Standard. Harmonic synchrophasor is useful for harmonic state estimation, Power Quality (PQ) monitoring, and harmonic power flow analysis. In this paper we investigate usability of the Standard basic synchrophasor estimation model for estimation of harmonic phasor up to the 50th harmonic as advised by the IEC Std 61000-4-7. For estimation of harmonic phasors an application of the flat-top FIR filter is proposed. Results for the maximally flat differentiator and the interpolated DFT are also presented, confirming the superior performance of the proposed flat-top filter approach. Harmonic phasor estimation is verified with extended tests of the IEEE Std C37.118.1(a) including steady-state and dynamic conditions with additive 60 dB noise.

20 February 2014 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KDKrzysztof Duda
Krzysztof Duda
SBSzymon Barczentewicz
Szymon Barczentewicz
This paper describes interpolated discrete Fourier transform (IpDFT) for parameter estimation of sinusoidal and damped sinusoidal signals analyzed with a sinα(x) window. For α = 0,2,4,...sinα(x) windows are Rife-Vincent class I (RVI) windows, for which IpDFT algorithms are known. We present a new IpDFTs for α = 1,3,5,.... The bias-variance trade-off of the proposed IpDFT fits between results offered by RVI windows, e.g., for α = 1, we get higher noise immunity than Hann (RVI order 1, α = 2) window and lower bias than rectangular (RVI order 0, α = 0) window.

11 March 2016 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KDKrzysztof Duda
Krzysztof Duda
TZTomasz P. Zielinski
Tomasz P. Zielinski
SBSzymon Barczentewicz
Szymon Barczentewicz
This paper describes a new method for designing flat-top cosine time windows. New perfectly flat-top windows, i.e., having monotonically decaying main lobe, and new equiripple flat-top windows, i.e., with some minor ripples of equal amplitude in the main lobe, are proposed. Perfect flatness (monotonic main lobe) is obtained by zeroing frequency derivatives of the window's spectrum at the origin. Perfect flatness is a new quality in flat-top windows, as all known flat-top windows have some ripples in the main lobe. New equiripple flat-top windows are designed based on the conditions imposed on the window's frequency response. The new flat-top windows are compared with the existing ones through the figures of merit, amplitude estimation example, and noise propagation analysis, showing superior performance of the former. The new windows are an excellent choice for popular digital waveform (spectrum) analyzers, as sine-waves amplitudes can be accurately estimated directly from the discrete Fourier transform spectrum without any further postprocessing.

23 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
Krzysztof PiatekKrzysztof Piatek
Krzysztof Piatek
AFAndrzej Firlit
Andrzej Firlit
KCKrzysztof Chmielowiec
Krzysztof Chmielowiec
MDMateusz Dutka
Mateusz Dutka
SBSzymon Barczentewicz
Szymon Barczentewicz
Zbigniew HanzelkaZbigniew Hanzelka
Zbigniew Hanzelka
Quality of power supply in power distribution systems requires continuous measurement using power quality analyzers installed in the grid. The paper reviews the published methods for optimal location of metering points in distribution systems in the context of power quality metering and assessment. Three methods have been selected for detailed analysis and comparative tests. It has been found that utilization of the methods is possible, but their performance varies highly depending on the test grid’s topology. Since the methods rely on the state estimation approach, their performance is strictly related to observability analysis. It has been found that standard observability analysis used for typical state estimation problem yields ambiguous results when applied to power quality assessment. Inherited properties of the selected methods are also analyzed, which allows for the formulation of general recommendations about optimal selection of metering points in a distribution system.

1 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
SBSzymon Barczentewicz
Szymon Barczentewicz
Tomasz LerchTomasz Lerch
Tomasz Lerch
Andrzej BienAndrzej Bien
Andrzej Bien
KDKrzysztof Duda
Krzysztof Duda
Constantly growing distributed energy generation based on renewable sources creates a number of new challenges for electrical power system operation. One of the challenges is islanding detection. Unintentional islanding, which can cause health and safety hazards for the personnel, is currently being experienced by a growing number of consumers/prosumers especially in the case of photovoltaic inverters. This work presents a new islanding detection method based on synchrophasor measurements. The proposed method works in either a passive or hybrid mode. In a passive mode, a single phasor measurement unit (PMU) in the island region is used. In a hybrid mode, one PMU in the island and another one outside the island are exploited. The proposed method was verified in conducted laboratory tests that confirmed the applicability of PMUs data for effective detection and monitoring of unintentional islanding.

15 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
KPKamil Prokop
Kamil Prokop
Andrzej BienAndrzej Bien
Andrzej Bien
SBSzymon Barczentewicz
Szymon Barczentewicz
Significant amounts of data need to be transferred in order to optimize the operation of power grids. The development of advanced metering and control infrastructure ensures a growth in the amount of data transferred within smart grids. Data compression is a strategy to reduce the burden. This paper presents current challenges in the field of time-series data compression. This paper’s novel contribution is the division of data in smart grids to real-time data used for control purposes and big data sets used for non-time-critical analysis of the system. Both of these two applications have different requirements for effective compression. Currently used algorithms are listed and described with their advantages and drawbacks for both of these applications. Details needed for the implementation of an algorithm were also provided. Comprehensive analysis and comparison are intended to facilitate the design of a data compression method tailored for a particular application. An important contribution is the description of the influence of data compression methods on cybersecurity, which is one of the major concerns in modern power grids. Future work includes the development of adaptive compression methods based on artificial intelligence, especially machine learning and quantum computing. This review will offer a solid foundation for the research and design of data compression methods.