Overcoming terrain obstacles presents a major problem for people with disabilities or with limited mobility who are dependent on wheelchairs. An engineering solution designed to facilitate the use of wheelchairs are assisted-propulsion systems. The objective of the research described in this article is to analyze the impact of the hybrid manual–electric wheelchair propulsion system on the kinematics of the anthropotechnical system when climbing hills. The tests were carried out on a wheelchair ramp with an incline of 4°, using a prototype wheelchair with a hybrid manual–electric propulsion system in accordance with the patent application P.427855. The test subjects were three people whose task was to propel the wheelchair in two assistance modes supporting manual propulsion. The first mode is hill-climbing assistance, while the second one is assistance with propulsion torque in the propulsive phase. During the tests, several kinematic parameters of the wheelchair were monitored. An in-depth analysis was performed for the amplitude of speed during a hill climb and the number of propulsive cycles performed on a hill. The tests performed showed that when propelling the wheelchair only using the hand rims, the subject needed an average of 13 ± 1 pushes on the uphill slope, and their speed amplitude was 1.8 km/h with an average speed of 1.73 km/h. The climbing assistance mode reduced the speed amplitude to 0.76 km/h. The torque-assisted mode in the propulsive phase reduced the number of cycles required to climb the hill from 13 to 6, while in the climbing assistance mode the number of cycles required to climb the hill was reduced from 12 to 10 cycles. The tests were carried out at various values of assistance and assistance amplification coefficient, and the most optimally selected parameters of this coefficient are presented in the results. The tests proved that electric propulsion assistance has a beneficial and significant impact on the kinematics of manual wheelchair propulsion when compared to a classic manual propulsion system when overcoming hills. In addition, assistance and assistance amplification coefficient were proved to be correlated with operating conditions and the user’s individual characteristics.
The work presented here describes the first results of an effective method of assessing the quality of electrostatic separation of mixtures of polymer materials. The motivation for the research was to find an effective method of mechanical separation of plastic materials and a quick assessment of the effectiveness of the method itself. The proposed method is based on the application of a dedicated vision system developed for needs of research on electrostatic separation. The effectiveness of the elaborated system has been demonstrated by evaluating the quality of the separation of mixtures of poly (methyl methacrylate) (PMMA) and polystyrene (PS). The obtained results show that the developed vision system can be successfully employed in the research on plastic separation, providing a fast and accurate method of assessing the purity and effectiveness of the separation process.
Purpose: The main purpose of the research conducted was the analysis of kinematic and biomechanical parameters measured during manual wheelchair ramp-climbing with the use of the anti-rollback system and the comparison of the values tested with the manual wheelchair climbing the same ramp but without any modifications. The paper presents a quantitative assessment relating to the qualitative research of the anti-rollback system performed by another research team. Method and materials: The article presents the measurement results of the wheelchair motion kinematics and the activity of four upper limb muscles for eight subjects climbing a 4.58° ramp. Each subject propelled the wheelchair both with and without the anti-rollback system. The kinematic parameters were measured by means of two incremental encoders with the resolution of 500 impulses per single revolution of the measurement wheel. Whereas, the muscle activity was measured by means of surface electromyography with the use of Noraxon Mini DTS apparatus equipped with four measurement channels. Results: The surface electromyography measurement indicated an increase in the muscle activity for all four muscles, during the use of the anti-rollback system. The increase was: 18.56% for deltoid muscle anterior, 12.37% for deltoid muscle posteriori, 13.0% for triceps brachii, and 15.44% for extensor carpi radialis longus. As far as the kinematics analysis is concerned, a decrease in the measured kinematic parameters was observed in most participants. The medium velocity of the propelling cycle decreased by 26%. The ratio of the generated power and the loss power in a single propelling cycle λ had decreased by 18%. The least decrease was recorded for the measurement of mechanical energy E and the propelling cycle duration time. For the total mechanical energy, the decrease level was 3%, and for the propelling cycle duration it was 1%. The research carried out did not demonstrate any impact of the anti-rollback system use on the push phase share in the entire propelling cycle.
Various distance sensors are used as measuring elements for positioning linear electrohydraulic drives. The most common are magnetostrictive transducers or linear variable differential transformer (LVDT) sensors mounted inside the cylinder. The displacement of the actuator’s piston rod is proportional to the change in the value of the current or voltage at the output from the sensor. They are characterized by relatively low measurement noise. The disadvantage of presented sensors is the need to mount them inside the cylinders and the high price. The article presents preliminary research on the replacement of following sensors and the use of a microelectromechanical system (MEMS) accelerometer as a measuring element in the electrohydraulic drive control system. The control consisted of two phases: at first, the signal from the acceleration sensor was analyzed during the actuator movement, based on the value determined from the simplified model implemented on the controller. In the range of motion in which the dynamics were the lowest, the signal was integrated and the obtained value was used in the second phase of motion. In the correction phase, a new set point was determined. Conducting the research required building a dedicated research stand. The author conducted the simulation and experimental research.
This paper presents the outcomes of investigations conducted on the development procedure of a personalized prosthetic device for an adult patient. The individualization is achieved through 3D scanning, followed by semi-automated design using the AutoMedPrint system, and low-cost fused deposition modelling (FDM) technology for 3D printing. The prosthesis is aimed for use during bicycle riding and other sport activities. During the conducted experiments outlined in this manuscript, the prosthesis is equipped with force and movement sensors. The purpose is to collect data on its functionality across different scenarios and dynamic activities, aiming to assess potential harm, refine the design, and serve as an initial step before activating the prosthesis end effector. This article describes the methodology in detail, including the process of designing, producing, and programming, as well as laboratory and field test results (including testing performed with and without a patient). Overall, the design and prototype are implemented successfully. A discussion about the need for particular improvements in both the mechanical and electrical areas is finally presented.
The aim of this study was to investigate and analyze the impact of selected parameters during the tribocharging process of shredded poly(ethylene terephthalate) (PET) and high-density polyethylene (PE-HD) plastics on accumulated electric charge and electrostatic separation effectiveness. The accumulation of electric charge on surfaces of polymer particles as a result of their circular motion forced by the airflow cyclone container was investigated. The impact of the container material, time of tribocharging and the airflow intensity were experimentally examined. A container in which the particles of the considered polymers are electrified with opposite charges was selected. A high ability to accumulate surface charge on small particles of both polymers was demonstrated. The electrified mixed PET/PE-HD was subjected to a separation process. An electrostatic separator designed and constructed by the authors was used for to the separation. In turn, to assess the effectiveness of this separation, a dedicated vision system was used. Based on the result of the carried out tests, it has been assumed that the proposed approach’s effectiveness has been demonstrated by means of empirical validation.