In this study, a low-air temperature sludge drying system was constructed and the effects of temperature and relative humidity on the characteristics of the system were investigated. The results showed that the drying rate of sludge increased with an increase in air temperature and a decrease in the air’s relative humidity. The influence of temperature on the average drying rate exhibited an approximate quadratic distribution, while the influence of relative humidity on the average drying rate exhibited an almost linear distribution. The relationship equations of the average drying rate, temperature, and humidity were summarized and compared with the experimental results, and the maximum relative error was 7.6375%. By comparing the experimental results with the commonly used thin-layer drying models, it was found that the sludge drying characteristics were more consistent with the Midilli model. Based on the relevant parameters of the Midilli model, the relationship between the segmented drying moisture content and the average drying rate was proposed, and the empirical formula of the drying rate and MR under different conditions was fitted.
To improve thermal insulation, microencapsulated phase change materials (micro-PCMs), expandable graphite (EG), and ammonium polyphosphate (APP) were introduced into polyurethane foam (PUF) to enhance the thermal stability and improve the thermal insulation behavior. The morphology of the PUF and micro-PCM was studied using a scanning electronic microscope (SEM), while the thermophysical properties of the PUF were investigated using a hot disk thermal constants analyzer and differential scanning calorimetry (DSC). The thermal stability of the PUF was investigated by thermogravimetric analysis (TGA), and the gas products volatilized from the PUF were analyzed by thermogravimetric analysis coupled with Fourier transform infrared spectrometry (TGA-FTIR). The results revealed that the thermal conductivities of the PUF were reduced because micro-PCM is effective in absorbing energy, showing that the PUF functions not only as a thermal insulation material but also as a heat sink for energy absorption. Moreover, the EG and APP were found to be effective in improving the thermal stabilities of the PUF, and the optimized formulation among EG, APP, and micro-PCMs in the PUF showed a significant synergistic effect.
In this work, the freezing characteristics of double-droplet impact on three typical wettability surfaces were investigated by coupling the solidification and melting VOF models. Different temperature conditions were adopted to study the influence of icing speed on droplet behavior. Simulation results show that the motion of the double-droplet impact is consistent with that of a single droplet in the early spreading stage but behaves differently in the retraction stage. The wetting area evolution during the impact-freezing process shows different tendency for hydrophilic and hydrophobic surfaces: Compared with single droplets, double droplets have a smaller wetting area factor on hydrophilic surfaces but a larger one on superhydrophobic surfaces. In addition, three typical impact results are observed for the double-droplet impact on a superhydrophobic cold surface: full rebound, adhesive avulsion, and full adhesion, which reflects the interaction of droplet merging and solidification during the impact freezing of the double droplet. These findings may deepen our understanding of the mechanism of impact freezing on a cold surface, it provides reference for the associated applications and technologies in icing/anti-icing.
Based on the sludge mass transfer flux model, this paper conducts a simulation study on the drying characteristics of sludge under low-temperature environment and compares it with the previous experimental results. It is found that when the sludge moisture content is low, the change of its drying curve is basically consistent with the experimental results, but there is a large error when the sludge moisture content is 0.4–0.6. In order to better simulate sludge drying characteristics, a model of cracking and shrinkage coefficients based on sludge moisture content is proposed, and the effective diffusion coefficient and mass transfer coefficient are modified. The maximum error between simulation and experiment is reduced to 23.78%. Based on this model, the sludge drying mechanism was studied. It was found that heat transfer and diffusion played a major role in the initial stage of sludge drying, and diffusion played a major role in sludge drying 30 min later.
The thermal comfort of preschool children was assumed to be similar to that of young adults, which may cause inaccuracy. This study tested and analyzed the thermal response characteristics of young adults and preschool children (4–6 years old) and the differences in thermal sensation and thermal physiology between the two groups of participants in a room with a radiant floor heating system using the difference analysis methods (the paired data t-test, the Mann–Whitney U test and the Kruskal–Wallis H test). Participants were divided into two groups, young adults and preschoolers, and were sat in each condition while wearing winter clothing with a thermal resistance of 1.02 clo. The results showed that when the indoor temperature changed, there was a significant difference in the local skin temperature of the calf between the two groups of participants (p < 0.05). Preschool children adapt to the thermal environment better than adults, and the difference in metabolic rate is one of the influencing factors. The overall thermal sensation with mean skin temperature of the different populations was linearly correlated; correlation coefficients were 0.944 and 0.932, respectively. The overall thermal sensation of the participants was linear with respect to the indoor operative temperature. Preschool children have a higher thermal sensitivity to temperature change than young adults under low-temperature radiant floor heating systems, indicating that children have different thermal awareness from adults. There were significant differences in preschoolers’ subjective assessments of thermal sensation when the predicted mean vote (PMV) model was used as the evaluation standard; the difference ranged from 0.77 to 2.33. Thus, the PMV-predicted percentage dissatisfied (PPD) model is not suitable for preschool children.