Juan A. Martín-Ramos

Dr. Juan A. Martín-Ramos


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2015 in Energies
Verified
Journal Article
Open access
PDF file
LALourdes Alvarez
Lourdes Alvarez
RPRogelio Peón
Rogelio Peón
JMJuan Martinez
Juan Martinez
MPMiguel J. Prieto
Miguel J. Prieto
JMJuan A. Martín-Ramos
Juan A. Martín-Ramos
ARAntonio Nevado Reviriego
Antonio Nevado Reviriego
Parabolic trough solar power plants use a thermal fluid to transfer thermal energy from solar radiation to a water-steam Rankine cycle in order to drive a turbine that, coupled to an electrical generator, produces electricity. These plants have a heat transfer fluid (HTF) system with the necessary elements to transform solar radiation into heat and to transfer that thermal energy to the water-steam exchangers. In order to get the best possible performance in the Rankine cycle and, hence, in the thermal plant, it is necessary that the thermal fluid reach its maximum temperature when leaving the solar field (SF). Also, it is mandatory that the thermal fluid does not exceed the maximum operating temperature of the HTF, above which it degrades. It must be noted that the optimal temperature of the thermal fluid is difficult to obtain, since solar radiation can change abruptly from one moment to another. The aim of this document is to provide a model of an HTF system that can be used to optimize the control of the temperature of the fluid without interfering with the normal operation of the plant. The results obtained with this model will be contrasted with those obtained in a real plant.

8 November 2004
Verified
Conference Paper
Closed access
JAJ. Arias
J. Arias
FLFRANCISCO MANUEL FERNANDEZ LINERA
FRANCISCO MANUEL FERNANDEZ LINERA
JMJuan A. Martín-Ramos
Juan A. Martín-Ramos
Alberto PerníaAlberto Pernía
Alberto Pernía
JCJ. Cambronero
J. Cambronero

12 October 2017 in Energies
Verified
Journal Article
Open access
PDF file
Alberto PerníaAlberto Pernía
Alberto Pernía
MPMiguel J. Prieto
Miguel J. Prieto
Pedro Villegas SaizPedro Villegas Saiz
Pedro Villegas Saiz
JGJuan Diaz gonzalez
Juan Diaz gonzalez
JMJuan A. Martín-Ramos
Juan A. Martín-Ramos
Medical X-ray appliances use high-voltage power supplies that must be able to work with very different energy requirements. Two techniques can be distinguished in X-ray medical imaging: fluoroscopy and radioscopy. The former involves low power radiation with a long exposure time, while radioscopy requires large power during short radiographic exposure times. Since the converter has to be designed by taking into account the maximum power specification, it will exhibit a poor efficiency when operating at low power levels. Such a problem can be solved by using a new multilevel LCC topology. This topology is based on a classical series-parallel resonant topology, but includes an additional low-voltage auxiliary transformer whose function depends on the X-ray technique considered. When radioscopy operation is selected, the transformer will allow the power to be shared between two full-bridges. If fluoroscopy mode is activated, the auxiliary full bridge is disconnected and the magnetizing inductance of the auxiliary transformer is used to increase the resonant inductor in order to reduce the resonant currents, thus improving the efficiency of the converter.

2 July 2015 in Electronics Letters
Verified
Journal Article
Open access
PDF file
JMJuan A. Martín-Ramos
Juan A. Martín-Ramos
ÓPÓ. Pardo‐Vaquero
Ó. Pardo‐Vaquero
Pedro Villegas SaizPedro Villegas Saiz
Pedro Villegas Saiz
JMJuan Martinez
Juan Martinez
Alberto PerníaAlberto Pernía
Alberto Pernía
X‐ray power supplies must operate under a wide variety of conditions. In fluoroscopy mode, they must transfer from 20 W to 1.2 kW, while in radiography mode they reach up to 100 kW. Input voltage range is also wide: from 400 to 750 V. Designers must achieve full power with lower input voltage, accepting important drops in efficiency under other circumstances. A two‐inverter multilevel resonant topology is proposed to address these problems. Adapting the resonant elements, the resulting power stage is versatile enough to minimise the resonant current for both radiography and fluoroscopy. Input voltage fluctuations are compensated by the inverter operations.

24 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Alberto PerníaAlberto Pernía
Alberto Pernía
HAHECTOR ANDRES-MAYOR
HECTOR ANDRES-MAYOR
MPMiguel J. Prieto
Miguel J. Prieto
Pedro Villegas SaizPedro Villegas Saiz
Pedro Villegas Saiz
Fernando NuñoFernando Nuño
Fernando Nuño
JMJuan A. Martín-Ramos
Juan A. Martín-Ramos
The use of solar thermal power plants is considered a cost-effective alternative to produce renewable energy. Unlike other energy installations, in this type of plants the transfer and storage of energy has been solved by using molten salts. These salts run between two tanks through the steam generation system that feeds the turbine. Although the use of salts as a heat transfer fluid is considered an adequate solution, they are not without problems. One of them is the formation of blockages in the pipes due to a partial solidification of the salt, which leads to the shutdown of the installation, with the consequent economic losses. Fast location of these blockages in a minimally intrusive way is the objective pursued in this work. The method to achieve this is based on the use of a new magnetostrictive sensor that simplifies previous designs.

26 August 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JMJuan A. Martín-Ramos
Juan A. Martín-Ramos
OPOscar Pardo-Vaquero
Oscar Pardo-Vaquero
JGJuan Diaz gonzalez
Juan Diaz gonzalez
Fernando NuñoFernando Nuño
Fernando Nuño
Pedro Villegas SaizPedro Villegas Saiz
Pedro Villegas Saiz
Alberto PerníaAlberto Pernía
Alberto Pernía
Several applications need a high power, high output voltage ac/dc converter. The structure includes a dc/dc resonant stage, which is fed from a three-phase line. Due to standards, rectified dc input voltage varies largely from 400 to 750 V affecting the adversely overall design and current levels. In fact, losses in the inverter become unbearable if both switching frequency and transferred power are desired beyond a certain level. In those cases, it is necessary to connect several switches in parallel. As an alternative, the new switches can configure a new modular structure instead, adding more flexibility in the control to compensate input voltage variations. As a result, the required circulating current is reduced to a half, with benefits in total power losses. Moreover, the nature of the topology allows a reconfiguration of the resonant net (LCC) for low power, reducing even further the minimum circulating current under those conditions (fluoroscopy, for instance). In this paper, the new multilevel resonant topology is mathematically modeled and proposed for radiography and fluoroscopy. An example illustrates the design procedure for a given application at 100 kW, 50-150 kV.