Daniele Gallo

Prof. Daniele Gallo

Università della Campania 'Luigi Vanvitelli'
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2004 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Testa AlfredoTesta Alfredo
Testa Alfredo
Daniele GalloDaniele Gallo
Daniele Gallo
RLRoberto Langella
Roberto Langella
The harmonic and interharmonic analysis recommendations contained in the latest International Electrotechnical Commission (IEC) standards on power quality are considered. The spectral leakage problems due to synchronization errors of the analyzed waveforms with the window widths adopted are analyzed. Improvements of the signal processing recommended by the IEC, based on the utilization of the classical Hanning window in place of the rectangular window, are proposed and made compatible with the grouping technique introduced in the standards. Sensitivity analyses on simple case studies together with experimental results show the sensitivity of the signal processing recommended by the IEC to synchronization errors and the usefulness of the improvements proposed.

13 December 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ACAntonio Cataliotti
Antonio Cataliotti
VCValentina Cosentino
Valentina Cosentino
GCGabriella Crotti
Gabriella Crotti
AFAntonio Delle Femine
Antonio Delle Femine
Dario Di CaraDario Di Cara
Dario Di Cara
GTGIOVANNI TINE'
GIOVANNI TINE'

23 January 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PTPietro Tosato
Pietro Tosato
David MaciiDavid Macii
David Macii
MLMario Luiso
Mario Luiso
Davide BrunelliDavide Brunelli
Davide Brunelli
Daniele GalloDaniele Gallo
Daniele Gallo
CLCarmine Landi
Carmine Landi
Nowadays, the interest in low-cost and increasingly accurate phasor measurement units (PMUs) for active distribution systems is steadily growing. In this paper, an algorithm for synchrophasor, fundamental frequency, and rate of change of frequency estimation tailored for processing platforms with limited computational resources is described and characterized extensively in terms of both accuracy and processing time. The proposed solution harnesses the main advantages of two state-of-the-art algorithms, i.e., the interpolated discrete Fourier transform and the Taylor-Fourier transform. Such algorithms are combined and implemented in a computationally efficient manner to reduce processing time as much as possible, while ensuring good accuracy in the main testing conditions specified in the IEEE Standard C37.118.1-2011 and its Amendment C37.118.1a-2014. Estimation accuracy has been evaluated not only through simulations but also experimentally. The good consistency between simulation-based and experimental results provides clear evidence that the uncertainty contributions due to transducers, acquisition, and synchronization systems can be reasonably kept under control. The processing times of the algorithm, implemented on an embedded platform suitable for PMU prototyping, are compliant with the mandatory reporting rates of Class M PMUs.

17 January 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
AFAntonio Delle Femine
Antonio Delle Femine
Daniele GalloDaniele Gallo
Daniele Gallo
DGDomenico Giordano
Domenico Giordano
Carmine LandiCarmine Landi
Carmine Landi
MLMario Luiso
Mario Luiso
DSDavide Signorino
Davide Signorino
The assessment of the power quality could be a valuable tool to foster the efficiency of the railway systems. Power quality is a well-addressed topic in conventional AC 50/60 Hz power systems and many procedures, algorithms and measurement systems were presented in the international standards and widely discussed in the scientific literature. A less explored research field is the assessment of the power quality in the railway traction supply systems, in particular with reference to the DC and 16.7 Hz systems. The paper explores this theme, proposing an extension of the definitions and of the standard measurement procedures for some of main power quality indexes, well defined and widely used for conventional power systems, in order to be used also in all railway traction supply systems. The limits or difficulties of applicability are discussed with reference to measurements performed both on-board and in substation. The proposed procedures are applied to an experimental case of a real DC railway system with a large measurement campaign.

6 February 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GCGabriella Crotti
Gabriella Crotti
Daniele GalloDaniele Gallo
Daniele Gallo
DGDomenico Giordano
Domenico Giordano
Carmine LandiCarmine Landi
Carmine Landi
MLMario Luiso
Mario Luiso
MMMohammad Modarres
Mohammad Modarres
A setup for the measurement of the frequency response of voltage measurement transformers under actual waveform conditions is presented. It is based on a two-step procedure that makes use of high voltage gas insulated capacitors and a digital bridge. It allows calibrations using distorted waveforms, with a fundamental tone at medium voltage level and superimposed harmonics up to 20% and 15 kHz. Combined standard uncertainty in the measurement of the voltage transformer (VT) error is estimated at 200 μV/V for the ratio error and 300 μrad for the phase displacement up to 10 kHz. First applications to the measurement of the frequency response of VTs with different rated primary voltages up to 50 kV are presented.

17 September 2007 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Daniele GalloDaniele Gallo
Daniele Gallo
Carmine LandiCarmine Landi
Carmine Landi
Nicola PasquinoNicola Pasquino
Nicola Pasquino
NPNello Polese
Nello Polese
In this paper, the authors propose a methodology to guide the verification of single-phase energy meters under sinusoidal and nonsinusoidal conditions. At first, a brief review is presented about definitions of the quantities that should be measured or monitored for revenue purposes and their relationship with electrical quantities that are recognized to be important in terms of metering accuracy. Then, a design of an experiment that allows the testing meters under a combination of disturbances showing positive and negative correlations are described. Finally, a hardware and software system to perform verification procedures in complex situations is presented with some preliminary analyses.