The assessment of the power quality could be a valuable tool to foster the efficiency of the railway systems. Power quality is a well-addressed topic in conventional AC 50/60 Hz power systems and many procedures, algorithms and measurement systems were presented in the international standards and widely discussed in the scientific literature. A less explored research field is the assessment of the power quality in the railway traction supply systems, in particular with reference to the DC and 16.7 Hz systems. The paper explores this theme, proposing an extension of the definitions and of the standard measurement procedures for some of main power quality indexes, well defined and widely used for conventional power systems, in order to be used also in all railway traction supply systems. The limits or difficulties of applicability are discussed with reference to measurements performed both on-board and in substation. The proposed procedures are applied to an experimental case of a real DC railway system with a large measurement campaign.
2 October 2018 in IEEE Transactions on Instrumentation and Measurement
The most recent IEC standards about voltage transformers warn about nonlinearity, which may significantly impact the harmonic measurement performance. However, there is a lack of scientific literature about this topic: usually their characterization consists of frequency response measurements that are clearly not able to capture the nonlinear behavior. In this paper, an innovative approach based on recently developed simplified frequency-domain polynomial models is proposed. The method is applied to two different medium-voltage inductive transformers. Models are identified and validated with a large set of realistic primary waveforms injected by a proper setup. Experimental results confirm the remarkable accuracy of the proposed models especially for low-order harmonics, which are the most affected by nonlinearity.
The present paper contains considerations relative to the long debated thermodynamic derivation of two-temperature Saha equations. The main focus of our discourse is on the dependence of the multitemperature equilibrium conditions on the constraints imposed on the thermodynamic system. We also examine the following key issues related to that dependence: correspondence between constraints and equilibrium-equation forms that have appeared in the literature; presumed dominance of the free-electron translational temperature in the two-temperature expression of the equilibrium constant of the ionization reaction disagreement between the derivation methods based on, respectively, the extended second law of classical thermodynamics and axiomatic thermodynamics; and plausibility of the existence of entropic constraints.
16 April 2019 in IEEE Transactions on Instrumentation and Measurement
The paper presents a method for the frequency characterization of voltage transformers (VTs) for medium voltage (MV) grids which involves only sine waves. It is called extended SINDICOMP, since it is an extended version of the previously developed technique SINDICOMP. It requires, in the first step, an evaluation and a compensation of the non-linearity introduced by the VT when it is supplied with a 50 Hz sinusoidal input at rated value. Then, the VT is characterized with a low voltage sinusoidal frequency sweep from the second harmonic frequency up to the first resonance frequency. Some rules to build the approximated frequency response, starting from these two sets of data, are given in the paper. The proposed approach is applied to three commercial MV VTs. Significant improvement of the VT performance is obtained, compared to the use of a frequency response obtained from the low voltage characterization.